background image

22

Product Warranty

WARRANTY, DISCLAIMERS AND LIMITATION OF LIABILITY:
The Products are covered by the warranty set forth in the following paragraphs. The warranty is extended 
only to the original purchaser of the Products directly from the Seller (or an authorized dealer of Seller) 
as new merchandise. For a period of twelve (12) months from the date of original delivery to Buyer, 
the Products manufactured by the Seller are warranted to be free from functional defects in materials 
and workmanship, provided they are operated under conditions of normal use, and that repairs and 
replacements are made in accordance herewith. Products manufactured by third parties are warranted 
only under the warranty provided by such third party manufacturer for such products. Seller does not 
warrant bulbs. The foregoing warranties shall not apply to Seller’s Products or Products manufactured 
by third parties that have been disassembled, altered or repaired (other than proper replacement of 
bulbs) other than by Seller or if the Product has been subject to abuse, misuse, negligence or accident. 

Seller’s sole and exclusive warranty obligation and Buyer’s sole and exclusive warranty remedy 
consists of Seller, at its option, repairing or replacing free of charge Products manufactured by 
Seller: (a) which contain a defect covered by the warranty; (b) which are reported in writing to Seller 
not later than seven (7) days after the expiration of the twelve (12) month warranty period; (c) which 
are returned to Seller promptly after discovery of the defect; and (d) which are found to be defective 
by Seller upon Seller’s examination. Buyer shall pay all transportation charges. Products manufac-
tured by third parties must be returned to Seller within thirty (30) days of Seller’s invoice date for such 
Products. Products ordered by Buyer to be manufactured by Seller on a special order basis may be 
returned under Seller’s warranty policy for repair or replacement but may not be returned for credit.

SELLER SHALL NOT BE OTHERWISE LIABLE FOR ANY DAMAGES INCLUDING BUT NOT LIMITED 
TO INCIDENTAL DAMAGES, CONSEQUENTIAL DAMAGES, OR SPECIAL DAMAGES OR FOR 
ANY OTHER LOSS, DAMAGE PENALTY OR EXPENSE OF ANY KIND, INCLUDING, WITHOUT 
LIMITATION, LOSS OF PROFITS OR OVERHEAD REIMBURSEMENT, PERSONAL INJURY OR 
PROPERTY DAMAGE. THE AFORESAID WARRANTY OBLIGATION OF SELLER CONSTITUTES 
ITS SOLE LIABILITY, AND, UNDER NO CIRCUMSTANCES, SHALL THE MAXIMUM LIABILITY 
OF SELLER UNDER ANY LEGAL THEORY (e.g. CONTRACT, WARRANTY, NEGLIGENCE, 
PROMISSORY ESTOPPEL, STRICT LIABILITY, MISREPRESENTATION, TORT) AND FOR ANY 
REASON WHATSOEVER (e.g. DEFECT, DELAY OR OTHERWISE) EXCEED THE PURCHASE 
PRICE OF THE DEFECTIVE PART, REGARDLESS WHETHER THE CLAIM IS ASSERTED BY 
BUYER OR ANY OTHER PERSON OR ENTITY, THE LIABILITIES OF SELLER, AS ABOVE SET 
FORTH, SHALL NOT BE EXTENDED BECAUSE OF ADVICE GIVEN BY IT IN CONNECTION 
WITH THE DESIGN, INSTALLATION OR USE OF THE PRODUCTS OR PARTS THEREOF. 

THERE ARE NO EXPRESS OR IMPLIED WARRANTIES WHICH EXTEND BEYOND THE WARRANTIES 
SET FORTH ABOVE, SELLER MAKES NO WARRANTY OF MERCHANTABILITY OR FITNESS FOR 
A PARTICULAR PURPOSE WITH RESPECT TO THE PRODUCTS OR ANY PARTS THEREOF.

© 2003, 2013 GAMMEX 006288-00-09

Your warranty may be registered at http://www.gammex.com/warranty.asp

Summary of Contents for 404GS LE

Page 1: ...404GS LE Precision Small Parts Grey Scale Phantom Gammex User s Guide...

Page 2: ...12 Pin Target 12 Resolution Target Group 12 Phantom Specifications 14 Physical Specification 14 Tissue Mimicking Background Material 14 Low Scatter Anechoic Cysts 14 GreyScaleTargets 14 Harmonic Imag...

Page 3: ...for testing for Axial and lateral resolution targets at 1 3 5 and 6 cm for precise resolution mea surements Low scatter cyst imaging at 1 2 and 4 mm Attenuation coefficients of either 0 5 or 0 7 dB cm...

Page 4: ...cation Weigh your 404GS LE to monitor desiccation Weigh the phantom when you first receive it and then every 6 months Record the values on the data sheet Do not drop or damage the phantom Return the p...

Page 5: ...y oil or lanolin based gels as a coupling medium Poor transmission is a result of insufficient coupling Do not press the transducer into the scanning surface This damages the scanning surface and will...

Page 6: ...l in the 404GS LE is ultrasonically similar to human tissue This allows the use of normal scanner control settings and ensures that the performance measured with the phantom closely approximates the s...

Page 7: ...ou may notice that the tissue echoes near the bottom of the phantom fade into noise The depth at which usable echoes disappear is called the depth of penetration The depth markers on the phantom label...

Page 8: ...onic calipers to measure the distance between two of the vertical pin targets Repeat for two of the horizontal pin targets The vertical pins have 5 mm spacing while the horizon tal pins have 10 mm spa...

Page 9: ...tal width of the pin targets in the near mid and far fields of the image Notice how the pin targets are narrowest in the focal zone The pin width demonstrates the width of the ultrasound beam at that...

Page 10: ...e normal Measure the dimensions of the 4 mm cystic target to check the image geometry Use the calipers to measure from top to bottom and side to side Repeat with the other cystic target groups as part...

Page 11: ...cyst lower the gain until it just disappears Record this gain setting and use it for future grey scale measurements Freeze the image and visually evaluate the grey scale targets Match each target wit...

Page 12: ...eter 7 mm Placement 3 cm deep Pin Targets Diameter 0 1 mm Vertical spacing 5 mm at 1 9 cm deep Horizontalspacing 10mmat1and5cmdeep Resolution Target Groups 1 3 5 and 6 cm deep All acoustic measurement...

Page 13: ...13...

Page 14: ...e of speed of sound 1 5 m s C Attenuation coefficient 0 7 0 05 dB cm MHz 0 5 0 05 dB cm MHz refer to phantom side label Low Scatter Anechoic Cysts Speed of sound 1540 10 m s Temperature dependence of...

Page 15: ...uch attenuation as there would be if the higher frequency were used to generate the pulses at the transducer So higher frequency resolution occurs for greater depths within the subject than if convent...

Page 16: ...tely the metastases may not be detected The Quantitative Measurement ensures that the grey level signal is measured consistently The Qualitative Measurement ensures that grey levels are displayed on t...

Page 17: ...nt the contrast or difference in brightness between different echo levels will remain constant If the shape of the S curve changes the relative image brightness for each echo level will also change Fo...

Page 18: ...ed to B 1 Bo 1 and B 1 Changes in the system response can be identified by measuring the average pixel value of the grey scale targets and the background material as displayed on the video monitor Pix...

Page 19: ...manner each time Method Define a region of interest and measure the average echo level Procedure Baseline Test 1 Scan the grey scale targets and display them as large as possible Freeze the image 2 M...

Page 20: ...d by locating a grey bar step that approximates the brightness of the region of interest Note It is absolutely critical that all system control settings be precisely reproduced for these tests Errors...

Page 21: ...d environments the phantom weight should be checked every six months Phantoms used in high temperature low humidity environments or in mobile situations should be tested more frequently As the phantom...

Page 22: ...f the defect and d which are found to be defective by Seller upon Seller s examination Buyer shall pay all transportation charges Products manufac tured by third parties must be returned to Seller wit...

Page 23: ...epartment hours are Monday through Friday 7 30 am to 5 00 pm Central Time 1 800 GAMMEX 1 426 6391 1 608 828 7000 1 608 828 7500 Fax e mail sales gammex com Service Department hours are Monday through...

Page 24: ...24 Notes...

Page 25: ...gammex com e mail sales gammex com Gammex RMI LTD Broadway Business Centre 32A Stoney Street Nottingham NG1 1LL United Kingdom 44 0115 9247188 Fax 44 0115 9247189 e mail uksales gammex com Gammex RMI...