User module »DP-HR-U-CON-2-DH«
151
· Target and user modules (DP-HR-U)
Installation
Connecting the console devices
DisplayPort Out 1:
Connect the first console monitor.
DisplayPort Out 2:
Connect the second console monitor.
Micro In:
Connect the optional microphone of the local console.
Speaker:
Connect the optional speakers of the local console.
Keyb.:
Connect the PS/2 keyboard of the local console.
Mouse:
Connect the PS/2 mouse of the local console.
Keyb./Mouse:
Connect the USB keyboard and/or the USB mouse of the local
console.
Generic:
By default (
Keyb./Mouse
mode), you can use this interface to connect another
USB input device or supported displays or tablets.
Enable the
Generic HID
mode (see page 175 f.) if you want to connect another USB
input device. In this mode, data of the USB input device remains unaltered when
transmitted to the active target module.
USB Devices:
Connect any USB devices to these interfaces. The data stream of the
connected USB device is transmitted to a compatible target module with up to 16
Mbit/s.
NOTE:
Check the monitor's manual if the OSD provides a setting for the mode of
the DisplayPort input. If so, select the mode in which the image data is processed
according to the standard
DisplayPort 1.1
.
HINWEIS:
Console keyboard and console mouse can be connected to the user mod-
ule’s USB
or
PS/2 interfaces.
NOTE:
Mixed operation, for example connecting a USB mouse and a PS/2 key-
board is supported, too.
IMPORTANT:
With enabled
Generic HID
mode, it is
not
possible to operate the OSD
with a keyboard connected to the
Generic
socket.
Transmission 1
Main P
ower
Red. Power
Keyb./Mouse
Speaker
Generic
LED Out
Mouse
Keyb.
Transmission 2
Micro In
DisplayPort
Out 1
Out 2
USB Devices
Summary of Contents for DP-HR-U
Page 1: ...A9200141 1 30 G D Target and User Modules Installation and Operation DP HR U variants EN ...
Page 194: ... ...
Page 195: ... ...