Configuration
G&D VisionXS-F-DP-UHR ·
69
English
Adjusting the operating mode of the RS232 interface
In the default setting of the extender, you can connect any RS232-compatible device
to the
optional
RS232 interface of the console module. The RS232 data stream is
transmitted unchanged to the computer module.
For transmitting RS422 signals, you can use two
G&D RS232-422 adapters
. Each of the
adapters converts the RS232 interface of the console module and the computer mod-
ule into
RS422
interfaces.
How to set the operating mode of the RS232 interface:
IMPORTANT:
If you want to transmit
RS422
signals, in addition to using adapters,
you also need to change the operating mode of the
RS232
interfaces of both the
console
and
the computer module.
OSD
1. Press
Ctrl+Num
(
default
) to open the on-screen display.
2. Select the row
Console setup
and press
Enter
if you want to adjust the
operating mode of the RS232 interface of the console module (
CON
).
Select the row
Target setup
and press
Enter
if you want to adjust the
operating mode of the RS232 interface of the computer module (
CPU
).
3. Under
RS232 port mode
press
F8
to select on of the following options:
RS232
The data stream of an RS232 device is transmitted from the
computer module to the console module (
default
).
RS422
The data stream of an RS422 device is transmitted from the
computer module to the console module via separately
available
G&D RS232-422 adapters
.
4. Press
F2
to save your settings.