G&D VisionXS-IP-C-DP-UHR · 

88

English

Resetting the default settings

This function is used to reset the 

default

 settings of the KVM extender. By perform-

ing this function, the 

default

 settings mentioned on page 68 are reactivated.

How to reset the default settings:

NOTE: 

Open the local OSD of the console module by pressing the 

local hotkey

(

default

Alt

+

Num

) if you want to reset the 

local

 settings of the console module only 

instead of the settings of the extender system.

OSD

1. Open the remote OSD of the computer module by pressing 

remote hotkey

 

(

default

Ctrl

+

Num

) if you want to reset the settings of the extender system.

Open the local OSD of the console module by pressing the 

local hotkey

 

(

default

Alt

+

Num

) if you want to reset the local settings of the console mod-

ule.

2. Select the row 

System setup

 (remote OSD) or 

Console utility

 

(local OSD) and press 

Enter

.

3. Select the row 

Set system defaults 

and press 

Enter

.

4. Confirm the security prompt or cancel the process.

Summary of Contents for VisionXS-IP-C-DP-UHR

Page 1: ...A9100386 1 10 G D VisionXS IP C DP UHR DE Installation und Bedienung EN Installation and Operation...

Page 2: ...hluss G D bernimmt keine Gew hrleistung f r Ger te die nicht bestimmungsgem eingesetzt wurden nicht autorisiert repariert oder modifiziert wurden schwere u ere Besch digungen aufweisen welche nicht be...

Page 3: ...utzt Hochfrequenzenergie und kann diese ausstrahlen Wenn es nicht gem der Anleitung installiert wird kann es Funkst rungen ver ursachen Es wird jedoch keinerlei Garantie daf r bernommen dass die St ru...

Page 4: ...rsteinrichtung der KVM over IP Verbindung 26 Werkseinstellung der Module 26 KVM over IP Verbindung des Rechnermoduls konfigurieren 27 Konfiguration der Netzwerkschnittstelle 28 Konfiguration der globa...

Page 5: ...he der Webapplikation ausw hlen 51 Webapplikation beenden 52 Benutzer und Gruppen 53 Effizienter Einsatz der Rechteverwaltung 53 Das Effektivrecht 53 Effizienter Einsatz der Benutzergruppen 54 Verwalt...

Page 6: ...rung der Farbtiefe der zu bertragenden Bilddaten 78 Verwendung des Freeze Modus 79 DDC CI Unterst tzung de aktivieren 80 USB Tastaturmodus oder Generic USB de aktivieren 81 USB Ger t f r einen Neustar...

Page 7: ...Inhaltsverzeichnis G D VisionXS IP C DP UHR vi Deutsch Statusanzeigen 98 Technische Daten 99 Allgemeine Eigenschaften der Serie 99 Spezifische Eigenschaften der Ger te 101...

Page 8: ...vice has been disconnected from all power sources Disconnect all power plugs and all power supplies of the device D branchez toutes les sources d alimentation Avant l installation assurez vous que l a...

Page 9: ...ngsquelle verwenden Betreiben Sie dieses Ger t nur an einer geerdeten Spannungsquelle Verwenden Sie ausschlie lich die G D Netzteile Betreiben Sie dieses Ger t nur mit den mitgelieferten oder in der B...

Page 10: ...rauchte Batterien d rfen nicht in den Hausm ll geworfen werden Beachten Sie die g ltigen Vorschriften zur Entsorgung elektronischer Produkte CAUTION Risk of explosion if the battery is replaced by an...

Page 11: ...odule Sie k nnen die Module wahlweise als Extender oder Matrixswitch Module ver wenden Extender Module Konfigurieren Sie eine KVM over IP Verbindung zwischen dem Rechner und dem Arbeitplatzmodul Die k...

Page 12: ...ren auf Seite 34 Bei Beachtung der max L nge von Teilstrecken zwischen zwei aktiven Netzwerk komponenten jeweils bis zu 100 Meter ist die gesamte bertragungsl nge unbe schr nkt Lieferumfang Standardli...

Page 13: ...ionXS IP CON 1 EasyStart Flyer 1 Sicherheitshinweise Flyer Zus tzlicher Lieferumfang erweiterter Varianten Die erweiterten Varianten der Arbeitsplatzmodule der VisionXS IP C DP UHR Serie werden zus tz...

Page 14: ...sche Daten auf Seite 99 in der unmittelbaren N he eingehalten und nicht durch andere Ger te beeinflusst wird Sorgen Sie f r eine ausreichende Luftzirkulation WICHTIG Bei Ger tevarianten mit L ftungs f...

Page 15: ...n Sie hierzu das Kabel USB AM BM 2 HINWEIS Alle Ger tevarianten der VisionXS IP Serie k nnen mit einer externen Spannungsversorgung an der Power Schnittstelle bei DT Varianten Main Power betrieben wer...

Page 16: ...u ein Audio Anschlusskabel Audio M M 2 Serial Verbinden Sie eine 9 polige serielle Schnittstelle des Rechners mit dieser Schnittstelle Verwenden Sie hierzu das Kabel RS232 M F 2 HINWEIS In der Standar...

Page 17: ...ist mit dem Gigabit Ethernet zu verbinden HINWEIS Die Freischaltung des kostenpflichtig erh ltlichen Transm Redundancy Features aktiviert die Transmission 2 Schnittstelle Verwenden Sie diese Schnittst...

Page 18: ...tes erreicht HINWEIS Alle Ger tevarianten der VisionXS IP Serie k nnen mit einer externen Spannungsversorgung an der Power Schnittstelle bei DT Varianten Main Power betrieben werden Die Abbildungen i...

Page 19: ...INWEIS Alle Ger tevarianten der VisionXS IP Serie k nnen mit einer externen Spannungsversorgung an der Power Schnittstelle bei DT Varianten Main Power betrieben werden Die Abbildungen in diesem Kapite...

Page 20: ...us unver ndert an das Rechnermodul bertragen WICHTIG Bei aktiviertem Generic USB Modus kann das OSD nicht mit einer Tasta tur an der Generic Buchse bedient werden WICHTIG Das Produkt erlaubt die gleic...

Page 21: ...S232 Schnittstellen verbinden modellabh ngig Line Out Schlie en Sie die Lautsprecher oder ein anderes Audioausgabeger t des Arbeitsplatzes an Serial Verbinden Sie das serielle Endger t mit dieser Schn...

Page 22: ...mit dem Gigabit Ethernet zu verbinden HINWEIS Die Freischaltung des kostenpflichtig erh ltlichen Transm Redundancy Features aktiviert die Transmission 2 Schnittstelle Verwenden Sie diese Schnittstelle...

Page 23: ...s Ger tes erreicht HINWEIS Alle Ger tevarianten der VisionXS IP Serie k nnen mit einer externen Spannungsversorgung an der Power Schnittstelle bei DT Varianten Main Power betrieben werden Die Abbildun...

Page 24: ...riebszustand des Moduls Weitere Hinweise hierzu erhalten Sie im Kapitel Statusanzeigen ab Seite 98 Bedienung Den am Rechnermodul VisionXS IP CPU angeschlossene Rechner k nnen Sie am ent fernten Arbeit...

Page 25: ...le E Benutzer abmelden und bet tigen Sie die Eingabetaste HINWEIS Falls anstelle der OpenAccess Betriebsart Standard im Extenderbetrieb die Betriebsart Standard eingestellt wurde fordert das System na...

Page 26: ...ch gef hrt werden HINWEIS Im Auslieferungszustand sind folgende Einstellungen vorausgew hlt IP Adresse der Netzwerkschnittstelle A Interface A 192 168 0 1 globale Netzwerkeinstellungen Bezug der Einst...

Page 27: ...ichtung und bet tigen Sie die Eingabetaste 3 W hlen Sie die Zeile Schnittstellen und bet tigen Sie die Eingabetaste 4 Erfassen Sie im Abschnitt Interface A folgende Daten 5 Bet tigen Sie die F2 Taste...

Page 28: ...stelle des Rechnermoduls 2 W hlen Sie die Zeile Netzwerkeinrichtung und bet tigen Sie die Eingabetaste 3 W hlen Sie die Zeile Schnittstellen und bet tigen Sie die Eingabetaste 4 Erfassen Sie im Abschn...

Page 29: ...bet tigen Sie die Eingabetaste 2 W hlen Sie die Zeile Host pingen und bet tigen Sie die Eingabetaste 3 Geben Sie im Feld Host die IP Adresse oder den Namen des Hosts ein und bet tigen Sie die Eingabe...

Page 30: ...um auch bei Ausfall eines ARP Targets eine R ckmeldung mindestens eines Targets zu erhalten So konfigurieren Sie die Einstellungen einer Netzwerkschnittstellen Gruppe 1 Starten Sie das entfernte OSD...

Page 31: ...elfaches von 100 ms der MII Link Monitoring Frequenz sein MII Up Delay Wartezeit in Millisekunden bevor eine wiederhergestellte Netzwerkschnittstelle aktiviert wird Der eingegebene Wert muss ein Vielf...

Page 32: ...lokale OSD des Arbeitsplatzmoduls mit dem lokalen Hotkey Stan dard Alt Num falls Sie die Einstellungen f r Arbeitsplatzmodul ndern m ch ten 2 W hlen Sie die Zeile Netzwerk Einrichtung und bet tigen Si...

Page 33: ...nbetriebnahme anpassen Die IP Adressen und die KVM over IP Einstellungen sind wie folgt vorkonfiguriert WICHTIG Wenn Sie den KVM Extender als Matrixswitch Endger t mit dem IP Matrixswitch ControlCente...

Page 34: ...se des Rechnermoduls Host sowie die Angabe des Control Ports des Rechnermoduls erforderlich Die Konfiguration der Communication Ports und Data Ports werden automatisch zwi schen beiden Modulen ausgeta...

Page 35: ...n komplexen Netzwerken sicher dass der KVM Extender aus allen Teilnetzwerken erreichbar ist So konfigurieren Sie die globalen Netzwerkeinstellungen 1 Verwenden Sie den Remote Hotkey Strg Num zum Aufru...

Page 36: ...lungen folgende Daten 4 Bet tigen Sie die F2 Taste zur Speicherung der durchgef hrten nderungen Globale Einstellungen Bet tigen Sie die F8 Taste zur Auswahl des Betriebsmodus Static Verwendung von sta...

Page 37: ...sicher dass der KVM Extender aus allen Teilnetzwerken erreichbar ist So konfigurieren Sie die globalen Netzwerkeinstellungen 1 Verwenden Sie den lokalen Hotkey Alt Num zum Aufruf des Arbeitsplatzmodu...

Page 38: ...aste zur Speicherung der durchgef hrten nderungen Globale Einstellungen Bet tigen Sie die F8 Taste zur Auswahl des Betriebsmodus Statisch Verwendung von statischen Einstellungen DHCP Bezug der Einstel...

Page 39: ...rget 1 Verwenden Sie den lokalen Hotkey Alt Num zum Aufruf des Arbeitsplatzmodul OSD 2 Bet tigen Sie F11 zum Aufruf des Konfiguration Men s 3 W hlen Sie die Zeile KVM Verbindung und bet tigen Sie die...

Page 40: ...emote Target und bet tigen Sie F4 Taste 6 Best tigen Sie die Sicherheitsabfrage um das Remote Target zu l schen Name Geben Sie den im Select Men anzuzeigenden Namen der G D Gegenstelle ein Host Name G...

Page 41: ...ie die bertragung an unterschiedliche Bandbreitenanforder ungen anpassen So stellen Sie das Bandbreiten Limit der KVM over IP Verbindung ein 1 Verwenden Sie den Remote Hotkey Strg Num zum Aufruf des R...

Page 42: ...te 1 Verwenden Sie den Remote Hotkey Strg Num zum Aufruf des Rechnermodul OSD 2 W hlen Sie die Zeile KVM Verbindung und bet tigen Sie die Eingabetaste 3 Erfassen Sie im Abschnitt Netzwerk Kontrolle fo...

Page 43: ...ativ die bertragung der Audio Daten deaktivieren So de aktivieren Sie die bertragung des Audio bzw RS232 Signals 1 Verwenden Sie den Remote Hotkey Strg Num zum Aufruf des OSD 2 W hlen Sie die Zeile KV...

Page 44: ...stellen d rfen eine KVM over IP Verbindung herstellen 5 W hlen Sie die Zeile Alle angeschlossenen Ger te zulassen und bet tigen Sie die Ein gabetaste wenn Sie bei aktiviertem UID Locking allen angesch...

Page 45: ...dul konfigurieren Die konfigurierten Remote Target k nnen anschlie end ber das lokale OSD des Arbeitsplatzmoduls aufgeschaltet werden Aufschaltung eines Remote Targets ber das OSD So schalten Sie ein...

Page 46: ...ten und anschlie ende Bet tigung der F8 Taste aus 5 W hlen Sie die Zeile G ltige Target Select Keys und bet tigen Sie die F8 Taste zur Auswahl einer der aufgelisteten Optionen 6 Bet tigen Sie die F2 T...

Page 47: ...bindung zu einem Remote Target beenden So beenden Sie die Verbindung zu einem Remote Target 1 Starten Sie das lokale OSD mit dem Hotkey Alt Num Standard 2 Bet tigen Sie die Tastenkombination Strg D um...

Page 48: ...xtenders k nnen Sie nur im entfernten OSD des Rechnermoduls einsehen und editieren TIPP Bet tigen Sie die Pause Taste um den Vorgang anzuhalten Ein Tasten druck auf die Leertaste f hrt den Vorgang for...

Page 49: ...Netzwerkeinrichtung KVM Verbindung Information ESC Kopfzeile Hier wird der Titel des aktuellen Men s angezeigt Listenfeld Im Listenfeld werden die Men eintr ge des ausgew hlten Men s aufgef hrt Zu un...

Page 50: ...angezeigte Men ansicht und zeigt das bergeordnete Men an Falls Eingaben ge ndert aber nicht gespeichert wurden erhal ten Sie diesbez glich eine Meldung Tabulatortaste Verwenden Sie diese Taste um die...

Page 51: ...en den verschiedenen Men eintr gen aufw rts Mausbewegung Runter Mit dieser Mausbewegung bewegen Sie die Positionsmarke im Listenfeld zwischen den verschiedenen Men eintr gen abw rts linke Maustaste Di...

Page 52: ...e ndern In der Standardeinstellung werden die Listeneintr ge der Mehrzahl der Men s in alphabetisch aufsteigender Reihenfolge Einstellung Alph sortiert So ndern Sie das Sortierkriterium und oder die R...

Page 53: ...olgende Einstellungen zur Konfiguration vorgenommen werden Funktion Erl uterung Arbeitsplatzeinrichtung Arbeitsplatztyp Seite 70 nderung des Namens des Arbeits platzmoduls Seite 71 Pers nliches Profil...

Page 54: ...Mitgliederverwaltung Seite 62 Superuser Recht Seite 64 Konfig Rechte Seite 65 Bedienrechte Seite 65 Target Zugriffsrechte Seite 66 Target USB Zugriffsrechte Seite 67 Netzwerkeinrichtung Schnittstelle...

Page 55: ...em Start des OSD mit der F12 Taste ge ffnet werden In diesem Men erhalten Sie folgende Informationen Funktion Erl uterung Passwort ndern Seite 72 Sprache Seite 72 Einblendung allgemein Seite 91 OSD Tr...

Page 56: ...n werden die Funktionen der Hauptmen s des lokalen OSD aufgelistet Auswahl Men Das Auswahl Men wird blicherweise unmittelbar nach dem Aufruf des OSD angezeigt Hier werden die im Extendersystem bekannt...

Page 57: ...entfernte OSD Seite 84 USB Auto Refresh Konfiguration ber das entfernte OSD Seite 85 OSD Tastatur Layout Seite 87 Generic USB Seite 83 Arbeitsplatz Utility Werkseinstellungen aktivieren Seite 88 Netz...

Page 58: ...kation 1 Klicken Sie auf das Sprachk rzel der aktuellen Sprache rechts oben 2 Schalten Sie die zu verwendende Sprache mit einem Klick auf die gew nschte Sprache um HINWEIS Grundlegende Informationen z...

Page 59: ...itzung der Webapplikation So beenden Sie die Webapplikation 1 Klicken Sie auf das Benutzersymbol rechts oben 2 Klicken Sie auf Abmelden um die aktive Sitzung zu beenden WICHTIG Verwenden Sie immer die...

Page 60: ...rde hingegen direkt im Benutzerkonto vergeben TIPP Bei entsprechender Planung und Umsetzung der Benutzergruppen sowie der zugeordneten Rechte ist es m glich die Rechteverwaltung nahezu vollst n dig be...

Page 61: ...IT und die entsprechenden Benutzerkonten zuzuordnen Ist eine weitere Differenzierung zwischen den Kompetenzen der Anwender erfor derlich k nnen weitere Gruppen eingerichtet werden BEISPIEL Sollen eini...

Page 62: ...e die Eingabetaste 3 Bet tigen Sie die F3 Taste und erfassen Sie folgende Daten 4 Bet tigen Sie die F2 Taste zur Speicherung Ihrer Eingaben und Erstellung des Benutzerkontos WICHTIG Der Administrator...

Page 63: ...rung des Passworts eines Benutzerkontos So ndern Sie das Passwort eines Benutzerkontos 1 Starten Sie das OSD mit dem Hotkey Strg Num Standard 2 W hlen Sie die Zeile Benutzereinrichtung und bet tigen S...

Page 64: ...ung Berechtigung Seite Eigenes Passwort ndern nderung des eigenen Passworts Seite 66 Pers nliches Profil nderung der Einstellungen des pers nlichen Profils eines Benuters Seite 65 Superuser Recht Zugr...

Page 65: ...welcher Sie das Benutzerkonto hinzuf gen oder aus welcher Sie das Benutzerkonto entfernen m chten 6 Bet tigen Sie die F8 Taste um das Benutzerkonto der ausgew hlten Benutzer gruppe hinzuzuf gen oder a...

Page 66: ...aste zur Auswahl einer der aufgelisteten Optionen 5 Bet tigen Sie die F2 Taste zur Speicherung der durchgef hrten nderungen L schen eines Benutzerkontos So l schen Sie ein Benutzerkonto 1 Starten Sie...

Page 67: ...So erstellen Sie eine neue Benutzergruppe 1 Starten Sie das OSD mit dem Hotkey Strg Num Standard 2 W hlen Sie die Zeile Benutzergruppeneinrichtung und bet tigen Sie die Eingabetaste 3 Bet tigen Sie d...

Page 68: ...Rechte einer Benutzergruppe Den verschiedenen Benutzergruppen k nnen differenzierte Berechtigungen erteilt werden Die folgende Tabelle listet die verschiedenen Berechtigungen auf Weiterf hrende Hinwe...

Page 69: ...e 5 W hlen Sie im Listenfeld ein Benutzerkonto das Sie der Benutzergruppe hinzu f gen oder aus dieser entfernen m chten 6 Bet tigen Sie die F8 Taste um das Benutzerkonto in die ausgew hlte Benutzer gr...

Page 70: ...Auswahl einer der aufgelisteten Optionen 5 Bet tigen Sie die F2 Taste zur Speicherung der durchgef hrten nderungen L schen einer Benutzergruppe So l schen Sie eine Benutzergruppe 1 Starten Sie das OSD...

Page 71: ...len Sie die Zeile Benutzergruppeneinrichtung und bet tigen Sie die Eingabetaste 3 W hlen Sie das Benutzerkonto bzw die Benutzergruppe deren Superuser Recht Sie ndern m chten und bet tigen Sie die F5 T...

Page 72: ...Speicherung der durchgef hrten nderungen Berechtigung zum Login in die Webapplikation So ndern Sie die Berechtigung zum Login mit der Webapplikation 1 Starten Sie das OSD mit dem Hotkey Strg Num Stan...

Page 73: ...die Rechnermodul Zugriffsrechte 1 Starten Sie das OSD mit dem Hotkey Strg Num Standard 2 M chten Sie dieses Recht eines Benutzerkontos ndern w hlen Sie die Zeile Benutzereinrichtung M chten Sie diese...

Page 74: ...zergruppeneinrichtung und bet tigen Sie die Eingabetaste 3 W hlen Sie das Benutzerkonto bzw die Benutzergruppe deren Recht Sie ndern m chten und bet tigen Sie die F5 Taste 4 W hlen Sie die Zeile Targe...

Page 75: ...hrt Funktion Standardeinstellung Seite Betriebsarten von Arbeitsplatzmodulen OpenAccess 70 nderung des eigenen Passworts 72 Sprache ausw hlen deutsch 72 nderung des Hotkeys Strg 73 nderung der OSD Ta...

Page 76: ...einblendung ndern hellgr n 90 Anzeige der Informationseinblendung tempor r 91 Transparenz des OSD einstellen mittleres Durchscheinen 91 Automatisches Schlie en des OSD nach Inaktivit t deaktiviert 92...

Page 77: ...izierung Die Rechte des Benutzers k nnen ber die Einstellungen der Benutzerkonten indivi duell eingestellt werden So w hlen Sie die Betriebsart des KVM Extenders HINWEIS Diese Betriebsart ist standard...

Page 78: ...hlen Sie die Zeile Name und bet tigen Sie die Eingabetaste 4 Geben Sie den gew nschten Namen ein und bet tigen Sie die Eingabetaste 5 Bet tigen Sie die F2 Taste zur Speicherung der durchgef hrten nder...

Page 79: ...m Aufruf des Pers nlichen Profils 3 W hlen Sie die Zeile Passwort ndern und bet tigen Sie die Eingabetaste 4 Geben Sie im Men Eigenes Passwort ndern folgende Daten ein Neu Geben Sie das neue Passwort...

Page 80: ...lls Sie die Einstellungen f r das entfernte OSD ndern m chten ffnen Sie das lokale OSD des Arbeitsplatzmoduls mit dem lokalen Hotkey Standard Alt Num falls Sie die Einstellungen f r das lokale OSD nde...

Page 81: ...chten ffnen Sie das lokale OSD des Arbeitsplatzmoduls mit dem lokalen Hotkey Standard Alt Num falls Sie die Einstellungen f r das lokale OSD ndern m chten 2 W hlen Sie die Zeile System Einrichtung und...

Page 82: ...e die Einstellungen f r das lokale OSD ndern m chten 2 W hlen Sie die Zeile System Einrichtung und bet tigen Sie die Eingabetaste entferntes OSD bzw bet tigen Sie die F11 Taste lokales OSD 3 W hlen Si...

Page 83: ...es Betriebsmodus der RS232 Schnittstellen des Arbeits platz und des Rechnermoduls erforderlich OSD 1 Starten Sie das OSD mit dem Hotkey Strg Num Standard 2 W hlen Sie die Zeile Arbeitsplatzeinrichtung...

Page 84: ...Ausf hrliche Informationen hierzu finden Sie im separaten Handbuch zur Webapplikation Config Panel So w hlen Sie den EDID Modus des KVM Extenders HINWEIS Beachten Sie bei der Erstinbetriebnahme sowie...

Page 85: ...daten auf 18 bit Hierdurch kann die zu bertragende Datenmenge reduziert werden So ndern Sie die Farbtiefe der zu bertragenden Bilddaten HINWEIS Abh ngig vom Bildinhalt k nnen gegebenenfalls leichte Fa...

Page 86: ...n Zeit seit dem Verbindungsabbruch dargestellt So konfigurieren Sie den Freeze Modus OSD 1 Starten Sie das OSD mit dem Hotkey Strg Num Standard 2 W hlen Sie die Zeile Arbeitsplatzeinrichtung und bet t...

Page 87: ...e garantiert werden So konfigurieren Sie die DDC CI Unterst tzung eines Arbeitsplatzmoduls OSD 1 Starten Sie das OSD mit dem Hotkey Strg Num Standard 2 W hlen Sie die Zeile Arbeitsplatzeinrichtung und...

Page 88: ...splays und Tablets Sie k nnen den am KVM Extender angeschlossenen Rechner mit einem der unterst tzten Displays oder Tablets bedienen WICHTIG Der Generic USB Modus unterst tzt USB Massenspeicherger te...

Page 89: ...einen USB HID Modus EINGABEGER T EINSTELLUNG beliebiger USB Massenspeicher oder beliebiges USB Eingabeger t Generic USB WICHTIG Der Generic USB Modus unterst tzt viele der am Markt erh ltlichen USB M...

Page 90: ...l und auf jeden Fall wieder im Zugriff sein soll So priorisieren Sie ein USB Ger t f r den Neustart OSD 1 ffnen Sie das lokale OSD des Arbeitsplatzmoduls mit dem lokalen Hotkey Standard Alt Num 2 Bet...

Page 91: ...Pfeiltasten der Tastatur nicht wie erwartet funktionieren ist die Umstellung auf das Scancode Set 3 empfehlenswert So ndern Sie die Einstellung des Scancode Sets OSD 1 Starten Sie das OSD mit dem Hot...

Page 92: ...OSD 1 Starten Sie das OSD mit dem Hotkey Strg Num Standard 2 W hlen Sie die Zeile Arbeitsplatzeinrichtung und bet tigen Sie die Eingabetaste 3 W hlen Sie in der Zeile USB Auto Refresh durch Bet tigun...

Page 93: ...HINWEIS Diese Einstellung ist unabh ngig von den Bildschirmschoner Einstel lungen des am Rechnermodul angeschlossenen Rechners OSD 1 Starten Sie das OSD mit dem Hotkey Strg Num Standard 2 W hlen Sie d...

Page 94: ...duls mit dem Remote Hotkey Standard Strg Num falls Sie die Einstellungen f r das entfernte OSD ndern m chten ffnen Sie das lokale OSD des Arbeitsplatzmoduls mit dem lokalen Hotkey Standard Alt Num fal...

Page 95: ...nur die lokalen Einstellungen des Arbeitsplatzmodul zur cksetzen m chten OSD 1 Starten Sie das entfernte OSD des Rechnermoduls mit dem Remote Hotkey Standard Strg Num falls Sie die Einstellungen des...

Page 96: ...die angelegten Netzfilterregeln vollst ndig gel scht werden So l schen Sie die eingerichteten Netzfilterregeln OSD 1 Starten Sie das entfernte OSD des Rechnermoduls mit dem Remote Hotkey Standard Strg...

Page 97: ...tzt So ndern Sie die Einstellung der Informationseinblendung schwarz dunkelrot gr n dunkelgelb dunkelblau violett dunkelt rkis silber hellgr n gelb blau magenta hellt rkis wei OSD 1 Starten Sie das O...

Page 98: ...eine Wiederholung der Einblen dung erreichen OSD 1 Starten Sie das OSD mit dem Hotkey Strg Num Standard 2 Bet tigen Sie die F10 Taste zum Aufruf des Pers nlichen Profils 3 W hlen Sie in der Zeile Einb...

Page 99: ...g Num Standard 2 Bet tigen Sie die F10 Taste zum Aufruf des Pers nlichen Profils 3 W hlen Sie die Zeile Timeout der OSD Sitzung s und bet tigen Sie die Eingabetaste 4 Geben Sie die gew nschte Zeitspan...

Page 100: ...t dem Hotkey Strg Num Standard 2 Bet tigen Sie die F10 Taste zum Aufruf des Pers nlichen Profils 3 W hlen Sie die Zeile Men Position festlegen und bet tigen Sie die Eingabetaste 4 Verwenden Sie die Pf...

Page 101: ...lossene Rechner schon w h rend des Bootvorgangs Zugriff auf die Eigenschaften des entfernten Monitors hat ist eine Cache Funktion in den KVM Extender integriert Auch wenn das Rechner oder das Arbeitsp...

Page 102: ...tetreiber f r das Betriebssystem des Computers 4 F hren Sie die Datei aus und folgen Sie den Hinweisen des Installationsassistenten Einrichten einer Verbindung im Terminalemulationsprogramm So richte...

Page 103: ...ie IP Adresse des Arbeitsplatz bzw Rechnermoduls 1 Starten Sie das Arbeitsplatz bzw Rechnermodul neu W hrend des Bootvorgangs werden verschiedene Statusmeldungen im Terminalemulationsprogramm angezeig...

Page 104: ...en der Datenverbindung zu den entsprechenden Pins auf Arbeitsplatzmodul Rechnermodul RS232 Stecker RS232 Buchse Pin Nr Leitung Arbeitsplatz modul Rechner modul 1 nicht belegt n c n c 2 RxD Receive Dat...

Page 105: ...an nicht freigeschalteten Port angesteckt Schalten Sie den Port mit einem Feature Key frei aus Keine Verbindung zu einer Gegenstelle hergestellt Network gr n an Die Verbindung mit dem Netzwerk wurde...

Page 106: ...Line Out RS232 Varianten A und AR 1 RS232 Stecker Serial bertragung zur G D Gegenstelle bertragungsart KVM over IP Kanalanzahl 1 1 optional Der zweite bertragungskanal kann mit einem optional k uflic...

Page 107: ...3840 2160 60Hz Ultra HD 60Hz 4096 2160 60Hz 4Kp60Hz Weitere nach VESA und CTA standardi sierte Aufl sungen sind im Rahmen der unterst tzten Videobandbreite Pixelrate und Horizontal Vertikalfrequenz m...

Page 108: ...ttstelle f r Rechner Video 1 DisplayPort Buchse Schnittstelle zur Gegenstelle KVM Audio und RS232 1 1 optional RJ45 Buchse 1 GBit s 2 5 GBit s 5 GBit s 10 GBit s Stromaufnahme Hauptstromversorgung 12...

Page 109: ...uchse Schnittstelle zur Gegenstelle KVM Audio und RS232 1 1 optional RJ45 Buchse 1 GBit s 2 5 GBit s 5 GBit s 10 GBit s Stromaufnahme Hauptstromversorgung 12 VDC 1 9 A redundante Stromversorgung 100 2...

Page 110: ...hse Schnittstelle zur Gegenstelle KVM Audio und RS232 1 1 optional RJ45 Buchse 1 GBit s 2 5 GBit s 5 GBit s 10 GBit s Stromaufnahme Hauptstromversorgung 12 VDC 1 9 A redundante Stromversorgung 100 240...

Page 111: ...me Hauptstromversorgung 12 VDC 1 9 A Geh use Material Aluminium eloxiert Dimensionen B H T ca 109 40 184 mm Gewicht ca 0 9 kg VISIONXS IP CPU C DP UHR A UG Schnittstelle f r Rechner Video 1 DisplayPor...

Page 112: ......

Page 113: ...Deutsch...

Page 114: ...D will not provide warranty for devices that Are not used as intended Are repaired or modified by unauthorized personnel Show severe external damages that was not reported on the receipt of goods Hav...

Page 115: ...s equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful inter ference to radio communications However ther...

Page 116: ...of the network interfaces 25 Establishing a KVM over IP connection for the first time 26 Default setting of the modules 26 Configuring a KVM over IP connection of a computer module 27 Configuring the...

Page 117: ...g Panel 51 Basic operation of the web application 51 Starting the web application 51 Selecting the language of the web application 51 Closing the web application 52 Users and groups 53 Efficient right...

Page 118: ...pth of the image data to be transmitted 78 Freeze mode 79 Enabling or disabling DDC CI support 80 De Activating an USB keyboard or the Generic USB mode 81 Prioritizing a USB device for a reboot 83 Cha...

Page 119: ...Table of contents G D VisionXS IP C DP UHR vi English Status LEDs 98 Technical data 99 General features of the series 99 Specific features of devices 101...

Page 120: ...d branch de toutes les sources d alimentation D branchez toutes les fiches d alimentation et toutes les alimenta tions lectrique de l appareil Trennen Sie alle Spannungsversorgungen Stellen Sie vor de...

Page 121: ...laying cables Use earthed voltage source Only operate this device with an earthed voltage source Use exclusively the G D power pack Only operate this device with the power packs included in delivery o...

Page 122: ...t dispose of batteries in municipal waste Check local regulations for the disposal of electronic products ATTENTION Il y a danger d explosion s il y a remplacement incorrect de la batterie Mettre au r...

Page 123: ...n use the modules as either extender or matrix switch modules Extender modules Configure a KVM over IP connection between the computer and the console module The configured connection between the modu...

Page 124: ...page 34 When observing the max length of sections between two active network components up to 100 meters each the entire transmission length is unrestricted Package contents Standard package contents...

Page 125: ...odule VisionXS IP CON 1 EasyStart flyer 1 Safety instructions flyer Additional package contents of expanded variants The package contents of expanded variants of console modules of the VisionXS IP C D...

Page 126: ...e Technical data on page 99 ff close to the device The ambient temperature limit must not be influenced by other devices Ensure sufficient air circulation IMPORTANT Do not cover the ventilation openin...

Page 127: ...er s USB inter faces to this interface NOTE All device variants of the VisionXS IP series can be operated with an external power supply at the Power interface for DT variants Main Power The illustrati...

Page 128: ...t the omputer s Line Out interface to this interface Serial Use the RS232 M F 2 cable to connect one of the computer s 9 pin serial inter faces to this interface NOTE By default the KVM extender trans...

Page 129: ...nto this interface Connect the other end of the Gigabit Ethernet NOTE The activation of the Transm Redundancy feature activates the Transmission 2 interface Use this interface to establish a redundant...

Page 130: ...OTE All device variants of the VisionXS IP series can be operated with an external power supply at the Power interface for DT variants Main Power The illustrations in this chapter show the DT variant...

Page 131: ...rk NOTE All device variants of the VisionXS IP series can be operated with an external power supply at the Power interface for DT variants Main Power The illustrations in this chapter show the DT vari...

Page 132: ...any data of the USB device is not altered when transmitted to the computer module IMPORTANT If the generic USB mode is active the OSD cannot be operated by a keyboard connected to the Generic socket...

Page 133: ...onnecting audio and RS232 interfaces depending on model Line Out Connect the speakers or another audio output device Serial Connect the serial end device to this interface DP Out Line Out Serial Gener...

Page 134: ...this interface Connect the other end of the Gigabit Ethernet NOTE The activation of the Transm Redundancy feature activates the Transmission 2 interface Use this interface to establish a redundant tra...

Page 135: ...re NOTE All device variants of the VisionXS IP series can be operated with an external power supply at the Power interface for DT variants Main Power The illustrations in this chapter show the DT vari...

Page 136: ...ting status For further information about this topic also see the chapter Status LEDs on page 98 ff Operation You can operate the computer connected to the VisionXS IP CPU computer module at the remot...

Page 137: ...out entry and press Enter HINWEIS If the standard operating mode was set instead of the OpenAccess opera ting mode default for extender operation the system asks you to log in after the console module...

Page 138: ...tly at the console NOTE In the default settings the following settings are preselected IP address of Network Interface A 192 168 0 1 global network settings settings are obtained via DHCP IMPORTANT At...

Page 139: ...omputer module 2 Select the entry Network setup and press Enter 3 Select the entry Interfaces and press Enter 4 Enter the following data under Interface A 5 Press F2 to save your settings Operational...

Page 140: ...to open the remote OSD to configure the network interface of the computer module 2 Select the entry Network setup and press Enter 3 Select the entry Interfaces and press Enter 4 Enter the following d...

Page 141: ...ault Ctrl Num to open the remote OSD of the computer module Select the entry Network setup and press Enter 2 Select the entry Ping host and press Enter 3 Use the Host entry to enter the IP address or...

Page 142: ...n you should determine several ARP targets in order to obtain a response from at least one target even if an ARP target fails How to configure the settings of grouped network interfaces 1 Open the rem...

Page 143: ...st be a multiple of 100 ms the MII link monitoring frequency MII up delay Waiting period in milliseconds before a reset network inter face is activated The entered value must be a multiple of 100 ms t...

Page 144: ...ant to change the configuration of the computer module Open the local OSD of the console module by pressing the local hotkey default Alt Num if you want to change the configuration of the console modu...

Page 145: ...g uration of both modules after their initial operation Both the IP addresses and the KVM over IP settings are preconfigured as follows IMPORTANT If you use the KVM extender as a matrix module with th...

Page 146: ...establish a KVM over IP connection through the console module The configuration of both the communication ports and the data ports are automati cally exchanged between the two modules NOTE Use the lo...

Page 147: ...ngs ensure that the KVM extender is available from all partial networks How to configure global network settings 1 Use the remote hotkey Ctrl Num to open the OSD of computer module 2 Select the entry...

Page 148: ...r module 2 Select the entry KVM connection and press Enter 3 Enter the following data under Network setting 4 Press F2 to save your settings Global preferences Press F8 to select the global preference...

Page 149: ...al networks How to configure global network settings 1 Use the local hotkey Alt Num to open the OSD of the console module 2 Press F11 to open the Configuration menu NOTE Use the local hotkey default A...

Page 150: ...n and press Enter 4 Enter the following data under Local 5 Press F2 to save your settings Global preferences Press F8 to select the global preferences Static uses static settings DHCP obtains settings...

Page 151: ...Use the local hotkey Alt Num to open the OSD of the console module 2 Press F11 to open the Configuration menu 3 Select the entry KVM Connection and press Enter 4 Select the entry Remote target and pre...

Page 152: ...to delete and press the F4 key 6 Confirm the safety prompt to delete the remote target Name Enter the name of the G D remote station to be displayed in the Select menu Hostname Enter the IP address ho...

Page 153: ...manual bandwidth management you can adapt the transmis sion to different bandwidth requirements How to set a limit for the bandwidth of a KVM over IP connection 1 Use the remote hotkey Ctrl Num to ope...

Page 154: ...e the DSCPs of the IP data packets 1 Use the remote hotkey Ctrl Num to open the OSD of the computer module 2 Select the row KVM connection and press Enter 3 Enter the following data under Network cont...

Page 155: ...on you can enable the transmission of RS232 data and alternatively disable the transmission of audio data How to de activate the transmission of audio or RS232 signals 1 Use the remote hotkey Ctrl Num...

Page 156: ...t UID Only the remote stations specified in the list may establish a KVM over IP connection 5 Select the row Permit all connected devices and press Enter if UID Locking is activa ted and you want to e...

Page 157: ...computer modules as remote targets see page 32 ff in the console module The configured remote targets can be connected via the local OSD of the console mod ule Accessing a remote target via OSD How to...

Page 158: ...erward press F8 5 Select the Valid target Select Keys entry and press F8 to select one of the following options 6 Press F2 to save your settings Ctrl Ctrl key Alt Alt key Alt Gr Alt Gr key Win Windows...

Page 159: ...of a remote target on page 32 ff Disconnecting a remote target How to disconnect a remote target 1 Start the local OSD with the Alt Num hotkey default 2 Press the Ctrl D key combination to disconnect...

Page 160: ...the console module You can view and edit the settings of the KVM extender only in the remote OSD of the computer module ADVICE Press Pause to stop the process Pressing Space continues the process NOTE...

Page 161: ...stem setup Network setup KVM connection Information ESC Header The header shows the title of the current menu List field The list field shows the menu items of the selected menu there are two types of...

Page 162: ...a submenu Esc This key closes the displayed menu and shows the superior menu A message is shown if entries are changed but not saved Tab key Use this key to move the cursor within the list field from...

Page 163: ...different menu entries in the list field Mouse movement Down This mouse movement moves the cursor downwards between the different menu entries in the list field Left mouse key This key is often used t...

Page 164: ...s are displayed in the Search field Changing the sort criteria of the list entries In the default settings the list entries are sorted alphabetically in ascending order default Alph How to change the...

Page 165: ...menu opens This menu enables you to configure the folloging settings Function Description Console setup Console type page 70 Renaming the console module page 71 Personal Profile page 48 Screensaver mi...

Page 166: ...Member management page 62 Superuser right page 64 Config rights page 65 Operation rights page 65 Target access rights page 66 Target USB access rights page 67 Network setup Interfaces Network page 20...

Page 167: ...SD press F12 to open the Information menu This menu pro vides the following information Function Description Change password page 72 Language page 72 Display page 91 OSD transparency page 91 OSD color...

Page 168: ...ges show the main menus of the OSD Select menu The Select menu is usually displayed after the OSD has been called The target modules of the extender system are displayed in this menu see IP MUX functi...

Page 169: ...ion via remote OSD page 84 USB auto refresh configuration via remote OSD page 85 OSD keyb layout page 87 Generic USB page 83 Console utility Set system defaults page 88 Network Interfaces page 20 Link...

Page 170: ...f the web application How to change the language of the web application 1 Click the language identifier of the current language in the upper right corner 2 Switch the language to be used by clicking o...

Page 171: ...end the active session of the web application How to close the web application 1 Click on the user icon at the top right 2 Click on Logout to exit the active session IMPORTANT To protect the web appli...

Page 172: ...ght is given directly in the user account ADVICE Rights administration can be carried out almost completely through user groups Therefore user groups and the assigned rights have to be planned and imp...

Page 173: ...sers with different rights e g Office and IT and assign the respective user accounts to these groups EXAMPLE Create more groups if you want to divide the user rights even further If for example you wa...

Page 174: ...the OSD 2 Select the User setup entry and press Enter 3 Press F3 and enter the following data 4 Press F2 to save your inputs and create an user account IMPORTANT The administrator and any user assigne...

Page 175: ...ing the password of a user account How to change the password of a user account 1 Press the Ctrl Num default hotkey to open the OSD 2 Select the User setup entry and press Enter 3 Select the user acco...

Page 176: ...pages Name Right Page Change own password Change own password page 66 Personal profile Change personal user settings page 65 Superuser right Unrestricted access to the configuration of the system pag...

Page 177: ...er 5 Select the user group to which you want to add a user account or from which you want to delete a user account 6 Press F8 to add the user account to or delete it from the selected user group 7 Rep...

Page 178: ...try and press F8 to select one of the following options 5 Press F2 to save your settings Deleting a user account How to delete a user account 1 Press the Ctrl Num default hotkey to open the OSD 2 Sele...

Page 179: ...n create up to 256 user groups within the system How to create a new user group 1 Press the Ctrl Num default hotkey to open the OSD 2 Select the User group setup entry and press Enter 3 Press F3 and e...

Page 180: ...r groups can be assigned with different rights The following table lists the different user rights Further information on the rights can be found on the indicated pages Name Right Page Change own pass...

Page 181: ...t the Member management entry and press Enter 5 Select the user account you want to add to or delete from the user group 6 Press F8 to add the user account to the selected user group or to delete it f...

Page 182: ...F8 to select one of the following options 5 Press F2 to save your settings Deleting a user group How to delete a user group 1 Press the Ctrl Num default hotkey to open the OSD 2 Select the User group...

Page 183: ...select the User setup entry For changing this right for a user group select the User group setup entry Press Enter 3 Select the user account or the user group whose Superuser rights you want to change...

Page 184: ...ptions 6 Press F2 to save your settings Changing the login right to the web application How to change the login right to the web application 1 Press the Ctrl Num default hotkey to open the OSD 2 If yo...

Page 185: ...access rights to a computer module 1 Press the Ctrl Num default hotkey to open the OSD 2 If you want to change this right for a user account select the User setup entry For changing this right for a u...

Page 186: ...For changing this right for a user group select the User group setup entry Press Enter 3 Select the user account or the user group whose rights you want to change and press F5 4 Select the Target USB...

Page 187: ...ge Operating modes of console modules OpenAccess 70 Changing your password 72 Selecting the language German 72 Changing hotkeys Ctrl 73 Changing the OSD key Num 74 Opening the OSD via double keypress...

Page 188: ...on display light green 90 Information display temporary 91 Adjusting the transparency of the OSD average transparency 91 Automatic closing of the OSD after inactivity disabled 92 Changing the position...

Page 189: ...ir username password and 2 factor authentication if set up User rights can be configured in the individual user account How to select the operating mode of the KVM extender NOTE This operating mode is...

Page 190: ...lt to open the OSD 2 Select the Console setup entry and press Enter 3 Select the Name entry and press Enter 4 Enter the new name and press Enter 5 Press F2 to save your settings OSD 1 Press Ctrl Num d...

Page 191: ...modules on page 70 ff OSD 1 Press Ctrl Num default to open the OSD 2 Press F10 to open the Personal Profile menu 3 Select the Change password entry and press Enter 4 Enter the new password into the Ch...

Page 192: ...he computer module by pressing the remote hotkey default Ctrl Num if you want to change the hotkey for the remote OSD Open the local OSD of the console module by pressing the local hotkey default Alt...

Page 193: ...lt Ctrl Num if you want to change the hotkey for the remote OSD Open the local OSD of the console module by pressing the local hotkey default Alt Num if you want to change the hotkey for the local OSD...

Page 194: ...ole module by pressing the local hotkey default Alt Num if you want to change the hotkey for the local OSD 2 Select the row System setup and press Enter remote OSD or F11 local OSD 3 Select the row Ho...

Page 195: ...pters you also need to change the operating mode of the RS232 interfaces of both the console and the computer module OSD 1 Press Ctrl Num default to open the OSD 2 Select the row Console setup and pre...

Page 196: ...d the EDID profile of a monitor The KVM extender will then transmit it to the connected computer For detailed information on this topic refer to the separate manual of the Config Panel web application...

Page 197: ...image data to 18 bits This will reduce the amount of data to be transmitted How to change the colour depth of the image data to be transmitted NOTE Depending on the image contents reducing the colour...

Page 198: ...ther a coloured frame and or a Frozen popup and the time passed since the connection has been interrupted How to configure the Freeze mode OSD 1 Press Ctrl Num default to open the OSD 2 Select the row...

Page 199: ...ible However we cannot guarantee the support for all monitors How to configure the DDC CI support of a console module OSD 1 Press Ctrl Num default to open the OSD 2 Select the row Console setup and pr...

Page 200: ...pported USB keyboards Displays and Tablets You can operated the computer connected to the KVM extender via a supported display or tablet IMPORTANT The generic USB mode supports USB mass storage device...

Page 201: ...is keyboard is pressed the action is transmitted to the connected computer How to select a USB HID mode INPUT DEVICE SETTING any USB mass storage or USB HID device Generic USB IMPORTANT The generic US...

Page 202: ...should be prioritized after a reboot and should be accessible in any case How to prioritize a USB device for a reboot OSD 1 Open the local OSD of the console module by pressing the local hotkey defau...

Page 203: ...th the scancode set 2 Use the scancode set 3 if you cannot enter the pipe or the arrow keys do not work as expected How to change the setting of the scancode set OSD 1 Press Ctrl Num default to open t...

Page 204: ...reinitialisation of USB input devices OSD 1 Press Ctrl Num default to open the OSD 2 Select the row Console setup and press Enter 3 Under USB auto refresh press F8 to select one of the following optio...

Page 205: ...ow to adjust the waiting period of the screensaver NOTE This setting does not affect the screensaver settings of the computer con nected to the computer module OSD 1 Press Ctrl Num default to open the...

Page 206: ...pen the remote OSD of the computer module by pressing the remote hotkey default Ctrl Num if you want to change the hotkey for the remote OSD Open the local OSD of the console module by pressing the lo...

Page 207: ...t the local settings of the console module only instead of the settings of the extender system OSD 1 Open the remote OSD of the computer module by pressing remote hotkey default Ctrl Num if you want t...

Page 208: ...o the netfilter rules The created netfilter rules can also be deleted with this function How to delete the created netfilter rules OSD 1 Open the remote OSD of the computer module by pressing remote h...

Page 209: ...ersonal profile The following colours are supported How to change the setting of the information display black dark red green dark yellow dark blue purple dark turquoise silver light green yellow blue...

Page 210: ...ary information display is active you can press the hotkey Ctrl Caps Lock to repeat the caption OSD 1 Press Ctrl Num default to open the OSD 2 Press F10 to open the Personal Profile menu 3 Under Displ...

Page 211: ...of the information display NOTE To disable the function enter the value 0 OSD 1 Press Ctrl Num default to open the OSD 2 Press F10 to open the Personal Profile menu 3 Select the row Close OSD when ina...

Page 212: ...he position of the OSD OSD 1 Press Ctrl Num default to open the OSD 2 Select the row Console setup and press Enter 3 Select the row Personal Profile and press Enter 4 Select the row Set menu position...

Page 213: ...connected to the computer module VisionXS IP CPU can already access the features of the remote monitor during boot ing the KVM extender contains a cache function Even when the computer module or the...

Page 214: ...d the device driver for the operating system installed on the computetr 4 Execute the file and follow the instructions of the installation wizard Establishing a connection by using a terminal emulator...

Page 215: ...e IP address How to determine the IP address of a user or computer module 1 Restart the user or computer module During the boot process the terminal emulator shows various status messages 2 After the...

Page 216: ...of the data connection are assigned to the according pins Console module Computer module RS232 plug RS232 socket Pin no Line Console module Computer module 1 not occupied n c n c 2 RxD Receive Data I...

Page 217: ...plugged into port that is not activated Unlock the port with a feature key off Connection to remote station has not been established Network green on The connection to the network has been successful...

Page 218: ...optional The second transmission channel can be unlocked with an optionally purchasable feature key Range max 100 meters Other interfaces Network 1 RJ 45 socket 100 MBit s Service 1 Micro USB socket...

Page 219: ...standardized accord ing to VESA and CTA are possible within the supported video bandwidth pixel rate and horizontal vertical frequency Vertical frequency 24 Hz to 240 Hz Horizontal frequency 25 kHz t...

Page 220: ...mputer Video 1 DisplayPort jack Interface to counterpart station KVM Audio and RS232 1 1 optional RJ 45 socket 1 GBit s 2 5 GBit s 5 GBit s 10 GBit s Current consumption Main power supply 12 VDC 1 9 A...

Page 221: ...rface to counterpart station KVM Audio and RS232 1 1 optional RJ 45 socket 1 GBit s 2 5 GBit s 5 GBit s 10 GBit s Current consumption Main power supply 12 VDC 1 9 A Redundant power suppply 100 240 VAC...

Page 222: ...ce to counterpart station KVM Audio and RS232 1 1 optional RJ 45 socket 1 GBit s 2 5 GBit s 5 GBit s 10 GBit s Current consumption Main power supply 12 VDC 1 9 A Redundant power suppply 100 240 VAC 60...

Page 223: ...er supply 12 VDC 1 9 A Casing Material anodised aluminium Dimensions W H D approx 109 40 184 mm Weight approx 0 9 kg VISIONXS IP CPU C DP UHR A UG Interface for computer Video 1 DisplayPort jack Inter...

Page 224: ......

Page 225: ...English...

Page 226: ......

Page 227: ...English...

Page 228: ...Drunck GmbH Systementwicklung Obere Leimbach 9 D 57074 Siegen Phone 49 271 23872 0 sales gdsys com www gdsys com US B ro US Office G D North America Inc 4001 W Alemada Avenue Suite 100 Burbank CA 915...

Reviews: