background image

STRONG. SIMPLE. COMPACT.

Rev Date 23 0610

800.285.6780   sales@ggled.net

EDGE

 INSTALLATION MANUAL PAGE 6

Pixel Information

• 

EDGE fixtures use 4 DMX channels per pixel in an RGBW configuration for each 2-foot-long pixel, but only 
the first three channels (RGB) are used (EDGE fixtures only contain red, green and blue LEDs). 

• 

When installing the system, check the length of the string of fixtures for each part of the building where the 
fixtures will be installed.  Do not connect more than 88 feet of fixtures to the 1A LED output, and do not 
connect a total of more than 88 feet of fixtures to the Driver 1 outputs (1A and 1B).  The same limits apply 
to the Driver 2 outputs (2A and 2B).  The B outputs (1B and 2B) have a limit of 40 feet.  G&G recommends 
that the split be as even as possible within these limits. For example, if possible, split 88 feet into a 48-foot 
string and a 40-foot string, or split 72 feet into two 36-foot strings.

• 

Please contact the G&G support team before making any changes to the layout of fixtures and leaders.  
The system has limits on how many fixtures and pixels can be connected to each driver and each output, 
and the support team will be able to tell if a change to the original layout will work or not.

• 

Consult the following table for the maximum lengths for each output and the mapping of EDGE pixels to 
each LED output. 

LED  

Output

DMX Start

Address

Maximum Length 

of All Fixtures

Maximum Number 

of Pixels

First 

Pixel

Last 

Pixel

1A

1

88 Feet

44

1

44

1B

177

40 Feet

20

45

64

2A

257

80 Feet

44

65

108

2B

433

40 Feet

20

109

128

Summary of Contents for EDGE

Page 1: ...azard if left unchecked This heating can also serve as an ignition source for gasses generated by the corrosion of metals inside of the enclosure Regularly scheduled inspections are recommended to ens...

Page 2: ...es Fixtures 2 Leader Cable s 3 Jumper Cable s 4 Termination Plug s 5 Mounting Brackets Ceiling or Wall 6 G G EDGE Power Data Translator PDT Includes controls power distribution and drivers 1 EDGE Stan...

Page 3: ...U fixtures in each string have 4 pin connectors THRU fixtures have a gray connector shell on the input end and a black connector shell on the output end while LEAD fixtures have black connector shells...

Page 4: ...ds using a chalk line or laser to mark the mounting bracket locations 2 4 and 6 fixtures require at least two mounting brackets Brackets should be installed near the ends of the fixtures 8 models requ...

Page 5: ...D at the bottom of the board below the driver fuses The input circuit shall be supplied with a 20A breaker on 120V systems or a 15A breaker on 277V systems Power Data Translator PDT Board The AC Input...

Page 6: ...The B outputs 1B and 2B have a limit of 40 feet G G recommends that the split be as even as possible within these limits For example if possible split 88 feet into a 48 foot string and a 40 foot stri...

Page 7: ...be connected to output 2A Failure to make the correct connections will lead to lighting effects being generated in an erratic manner To connect the leader cables to the LED Output terminals remove 2 3...

Page 8: ...ee discrete wires in the data cable these are marked on the board next to the terminals D D and COM Optionally the RJ45 8P8C connector can be used instead of the three terminals if the DMX source supp...

Page 9: ...be opened for outbound connections to allow the device to connect to our servers User Interface In order to access the ColorWash system you will need to create an account on the ColorWash dashboard a...