background image

Application notes and equipment

 

 

 

17 

Data logger Klima 20 / 30 

 

3.4 

Storage conditions 

Data  loggers  Klima  20  and  Klima  30  may  only  be  stored  in  the  packaging  that  is 
supplied  by  us  (also  available  as  accessory).  We  will  not  assume  any  liability  for 
damages, caused by non-compliance, to a device or the sensor system that is used in 
it. Fumigation from foam materials that have not been supplied by us may damage the 
sensor  system  and  lead  to  falsified  measuring  values.  Therefore  it  is  particularly 
important that the device is not stored in such a material.  

 
 

4  Application notes and equipment 

4.1 

General notes (Klima 30) 

The data logger Klima 30 has an internal sensor. It is also possible to connect 
an external temperature sensor. The temperature NT 3 as well as the 
temperature sensor NT 8 are can be connected by using the USB port. By 
connecting one of these sensors it is possible to measure the temperature of 
materials of all kind.  

 

4.1.1 

External temperatre sensor NT 3 & NT 8 (Klima 30) 

The  temperature  sensor  NT  3  or  NT  8  can  be  connected  to  the  data  logger 
Klima  30  through  the  USB  port.  The  temperature  sensor  is  automatically 
recognized by the data logger after connecting.  

For  the  measurement,  it  is  necessary  to  drill  a  hole  into  the  material.  The 
temperature sensor can be tucked in for the measurement of the temperature. 

The cable of the NT 3 is 3 meters long; the cable of the NT 8 is 8 meters long. 

 

4.1.2 

Wall mount 

In order to make convenient measurements, there is a wall mount for the data 
logger Klima 20 and Klima 30.  

Um bequeme Messungen vollziehen zu können, gibt es einen Wandhalter für 
den  Datenlogger  Klima  30.  By  mounting  the  data  logger  in  a  wall  mount  you 
can be sure that the data logger is always exposed to the same conditions for 
example the same air flow etc. The wall mount is magnetic at the backside or 
can be screwed or sticked into the wall. 

Summary of Contents for Klima 20

Page 1: ...1 Data logger Klima 20 30 EN Data logger Klima 20 30 Operating instructions Version 2 1...

Page 2: ...ols Klima 20 9 1 4 Device layout and button assignment Klima 30 8 1 5 Display symbols Klima 30 9 2 Basic functions 10 2 1 Commissioning 10 2 2 USB Port 10 2 3 Function button handling 11 2 3 1 Start S...

Page 3: ...Klima 30 15 3 2 Technical Data external temperature sensor 15 3 3 Prohibited environmental conditions 15 3 4 Storage conditions 16 4 Applications notes 16 4 1 General notes 16 4 1 1 External temperatu...

Page 4: ...be operated under the climatic conditions specified These conditions can be found in Chapter 3 1 Technical data This measuring device may likewise only be used under the conditions and for the purpose...

Page 5: ...ructions Keep the device and accessories out of the reach of children Measurements must not be carried out on metallic surfaces Gann Mess u Regeltechnik GmbH accepts no liability for damage resulting...

Page 6: ...and temperature sensors are available for the data loggers Wall mount Facilitates the measurement in a room Software Dialog D Computer program for transferring stored measurements for evaluation grap...

Page 7: ...roduction 7 Data logger Klima 20 30 1 2 Device layout and button assignment Klima 20 Internal sensor LCD display Start Stop Button USB Port LED red Figure 1 1 Device layout and button assignment Klima...

Page 8: ...y td dew point temperature Measurement 2 Min max und average temperature change in a 10 second clock Unit measurement 2 This sign informs about the currently selected measurement unit of reading 2 C F...

Page 9: ...0 30 1 4 Device layout and button assignment Klima 30 LCD display Start Stop Button Mode Button LED green red USB Port Connection for external temperature sensor Internal sensor Figure 1 3 Device layo...

Page 10: ...ll be displayed internal sensor Maximum minimum and average values Unit measurement 2 This sign informs about the currently selected measurement unit of reading 2 C F RH or td possible MIN MAX AVG Sho...

Page 11: ...or a few seconds Afterwards the device shows F5 for 30 seconds Then the device turns off The same happens after pressing any button 2 2 USB Port To configure the data logger Klima 20 Klima 30 connect...

Page 12: ...segment STOP expires and the LCD segment LOG appears Now the process of data recording starts To stop it press the Start Stop Button for 3 seconds 2 3 2 Mode Button only Klima 30 By pressing the Mode...

Page 13: ...layed if no external temperature sensor is connected to the data logger 2 5 Display elements figure 1 2 figure 1 4 The LCD display informs about two measurement values and it also informs about some s...

Page 14: ...ogger The data logger automatically adapt tot he temperature sensor you don t have to set the data logger When you disconnect the temperature sensor from the data logger please employ the white rubber...

Page 15: ...iately In this case the battery is no longer sufficient for further measurements 2 9 Battery life time The battery indication has 3 bar segments when its fully loaded At temperatures 0 the following v...

Page 16: ...1 8 R H 10 to 70 C 0 3 C Interface USB Port USB Port Working temperature 30 to 60 C 10 to 70 C Storage temperature 30 to 70 C 30 to 70 C Dimensions 92 x 55 x 21 L x W x H mm 88 x 55 x 20 L x W x H mm...

Page 17: ...onnecting one of these sensors it is possible to measure the temperature of materials of all kind 4 1 1 External temperatre sensor NT 3 NT 8 Klima 30 The temperature sensor NT 3 or NT 8 can be connect...

Page 18: ...ment 18 Data logger Klima 20 30 4 1 3 GANN Dialog Software D Klima 20 Klima 30 In the basic set of the data logger the GANN software dialog D is contained as well as the suitable cable MK 26 technical...

Page 19: ......

Reviews: