background image

Introduction

 

 

 

Data logger Klima 20 / 30 

0.1 

Publication statement 

This  publication  replaces  all  previous  versions.  It  may  not  be  reproduced  in 
any  form  or  processed,  duplicated  or  disseminated  using  electronic  systems 
without the written permission of Gann Mess- u. Regeltechnik GmbH. Subject 
to technical and documentary changes. All rights reserved. This document was 
prepared  with the  required  care.  Gann  Mess-  u. Regeltechnik  GmbH  accepts 
no liability for errors or omissions. 

 

GANN Mess- u. Regeltechnik GmbH, Gerlingen, Germany. 27/02/2014 

 

0.2 

General notes 

This measuring device fulfils the requirements of the applicable European and 
national  directives  (2004/108/EC)  and  standards  (EN61010).  Appropriate 
declarations  and  documentation  are  held  by  the  manufacturer.  To  ensure 
trouble-free  operation  of  the  measuring  device  and  operational  reliability,  the 
user must carefully read the operating instructions. The measuring device may 
only be operated under the climatic conditions specified. These conditions can 
be found in Chapter 3.1 "Technical data". This measuring device may likewise 
only  be  used  under  the  conditions  and  for  the  purposes  it  was  designed  for. 
Operational  reliability  and  functionality  are  no  longer  ensured  if  the  device  is 
modified  or  adapted. Gann  Mess-  u. Regeltechnik  GmbH  is  not  liable  for  any 
damage  arising  from  such  modifications  or  adaptations.  The  risk  is  borne  by 
the user alone. 

 

 

Using  appropriate  means,  make  always  sure  that  there  are  no 
electrical  cables,  water  pipes,  or  other  utility  lines  at  the  location,  at 
which the measurement is to be carried out. 

 

 

The  device  must  not  be  stored  or  operated  in  aggressive  air  or  air 
containing solvents! 

 

 

Material that is frozen or has wet surfaces cannot be measured. 

 

 

The  notes  and  tables  in  these  instructions  on  permitted  or  normal 
humidity  conditions  in  practice  and  the  general  definitions  of  terms 
have  been  taken  from  the  specialist  literature.  No  responsibility  can 
therefore  be  taken  by  the  manufacturer  for  the  correctness  of  this 
information.  The  conclusions  to  be  drawn  from  the  measurement 

Summary of Contents for Klima 20

Page 1: ...1 Data logger Klima 20 30 EN Data logger Klima 20 30 Operating instructions Version 2 1...

Page 2: ...ols Klima 20 9 1 4 Device layout and button assignment Klima 30 8 1 5 Display symbols Klima 30 9 2 Basic functions 10 2 1 Commissioning 10 2 2 USB Port 10 2 3 Function button handling 11 2 3 1 Start S...

Page 3: ...Klima 30 15 3 2 Technical Data external temperature sensor 15 3 3 Prohibited environmental conditions 15 3 4 Storage conditions 16 4 Applications notes 16 4 1 General notes 16 4 1 1 External temperatu...

Page 4: ...be operated under the climatic conditions specified These conditions can be found in Chapter 3 1 Technical data This measuring device may likewise only be used under the conditions and for the purpose...

Page 5: ...ructions Keep the device and accessories out of the reach of children Measurements must not be carried out on metallic surfaces Gann Mess u Regeltechnik GmbH accepts no liability for damage resulting...

Page 6: ...and temperature sensors are available for the data loggers Wall mount Facilitates the measurement in a room Software Dialog D Computer program for transferring stored measurements for evaluation grap...

Page 7: ...roduction 7 Data logger Klima 20 30 1 2 Device layout and button assignment Klima 20 Internal sensor LCD display Start Stop Button USB Port LED red Figure 1 1 Device layout and button assignment Klima...

Page 8: ...y td dew point temperature Measurement 2 Min max und average temperature change in a 10 second clock Unit measurement 2 This sign informs about the currently selected measurement unit of reading 2 C F...

Page 9: ...0 30 1 4 Device layout and button assignment Klima 30 LCD display Start Stop Button Mode Button LED green red USB Port Connection for external temperature sensor Internal sensor Figure 1 3 Device layo...

Page 10: ...ll be displayed internal sensor Maximum minimum and average values Unit measurement 2 This sign informs about the currently selected measurement unit of reading 2 C F RH or td possible MIN MAX AVG Sho...

Page 11: ...or a few seconds Afterwards the device shows F5 for 30 seconds Then the device turns off The same happens after pressing any button 2 2 USB Port To configure the data logger Klima 20 Klima 30 connect...

Page 12: ...segment STOP expires and the LCD segment LOG appears Now the process of data recording starts To stop it press the Start Stop Button for 3 seconds 2 3 2 Mode Button only Klima 30 By pressing the Mode...

Page 13: ...layed if no external temperature sensor is connected to the data logger 2 5 Display elements figure 1 2 figure 1 4 The LCD display informs about two measurement values and it also informs about some s...

Page 14: ...ogger The data logger automatically adapt tot he temperature sensor you don t have to set the data logger When you disconnect the temperature sensor from the data logger please employ the white rubber...

Page 15: ...iately In this case the battery is no longer sufficient for further measurements 2 9 Battery life time The battery indication has 3 bar segments when its fully loaded At temperatures 0 the following v...

Page 16: ...1 8 R H 10 to 70 C 0 3 C Interface USB Port USB Port Working temperature 30 to 60 C 10 to 70 C Storage temperature 30 to 70 C 30 to 70 C Dimensions 92 x 55 x 21 L x W x H mm 88 x 55 x 20 L x W x H mm...

Page 17: ...onnecting one of these sensors it is possible to measure the temperature of materials of all kind 4 1 1 External temperatre sensor NT 3 NT 8 Klima 30 The temperature sensor NT 3 or NT 8 can be connect...

Page 18: ...ment 18 Data logger Klima 20 30 4 1 3 GANN Dialog Software D Klima 20 Klima 30 In the basic set of the data logger the GANN software dialog D is contained as well as the suitable cable MK 26 technical...

Page 19: ......

Reviews: