Configuration Settings Table
The following table lists all the configuration information available for the GAT ECO.Side Lock 7000 BA in GAT Config
Manager.
Options
Description
Format
Default
Operating mode
General
Operating mode
Select the operating mode of the lock:
-
“FreeLocker”
-
“PersonalLocker_ProgrammingCard“
-
“PersonalLocker_ExpiryDate”
-
“FreeLocker_UniqueNumber”
-
“FreeLockerUniversal”
List option
Free Locker
Locker number
Enter the locker number here
Integer
30000
Beeper mode
Switch on/off the lock sound signal function
Boolean
True
Alarm mode
Switch on/off the alarm function
Boolean
False
AutoUnlock [min]
Unlock locker at a defined point in time. 0 = inactive
Integer
0
CardValidityDateRequired
When this option is activated, a valid expiration date must be
set on the data carriers so that they can be used (default value
of 1.1.2007 is not valid)
Boolean
False
LastOpenAtExpiredDate
When this option is activated, a locker can be unlocked one
more time using the data carrier that locked it (see "6.3.5
Personal Locker Expiry Date Mode").
Boolean
True
Free Locker
Use TimeLimit
Select the type of time limit for the locker (see "6.3.1
Free Locker Mode (with or without Duration of Use
Function)
“Duration” or “Point of time”
List option
Duration
TimeLimit (min)
Define the time limit in minutes
Integer
60
TimeLimit Interrupt Timeout
[min]
Minimum waiting time from the end of a locker usage period
until the next usage period can begin.
Integer
60
Personal Locker
Index PersonalLocker
Define the index of the personal locker
Integer
0
PreLock PersonalLocker
Switch on/off the automatic lock function without data
carrier for personal lockers
Boolean
False
PersonalLockerSecureFlag
When this option is activated, a new index or validity date can
only be transferred from a data carrier to the lock when the
locker is open. When this option is deactivated, transferal is
possible even when the locker is locked (see "6.3.5 Personal
Locker Expiry Date Mode")
Boolean
False