GAT ECO.Side Lock 7000 BA / NW BA
Configuration
www.gantner.com
HB_GAT-GAT-ECOSide-Lock7000-BA--EN_14
47
Options
Description
Format
Default
Reader
RF Standards
LEGIC
When set to “True”, LEGIC data carriers can be read
by the lock. This setting is not configurable
Boolean
True
ISO 15693
When set to “True”, ISO 15693 data carriers can be
read by the lock.
Boolean
False
ISO 14443A
When set to “True”, ISO 14443 (MIFARE) data carriers
can be read by the lock.
Boolean
False
Segment configuration
General
Site key
Site key of the device. All data carriers must have the
same site key to be used with the device.
Hex
9999
LEGIC prime
Options for LEGIC data carriers
SearchStr
Search string. This setting is not configurable
Integer
IA2200999
903
SearchStrLen
Search string length. This setting is not configurable
Integer
6
LegicLocker
Select the LEGIC locker
List option
Locker 1
Application
Master cards
Master Card 1 - 10
Fields to enter number for MASTER cards 1 to 10
and/or OPEN MASTER data carriers
Integer
Read only parameter
Production
Article Num
Article number of the device
Integer
Serial Num
Serial number of the device
Integer
Manufacturer Num
Manufacturer number of the device
Integer
Production Year
Production year of the device
Integer
Production Week
Production week of the device
Integer
HardwareUIDNum
Unique ID number of the hardware
Integer
Controller Type
Controller type of the device
Hardware Vers
Hardware version of the device
Integer
Bootloader Vers
Bootloader version of the device
Integer
Firmware Vers
Firmware version of the device
Integer
LockEngineVers
Lock logic version of the device
Integer
Table 5.1
– Configuration settings for the GAT ECO.Side Lock 7000 BA in GAT Config Manager
Summary of Contents for GAT ECO.Side Lock 7000 BA