Free Locker Unique Number Mode
“Free locker unique number” operating mode differs from the standard free locker mode in the following ways:
-
All MIFARE and ISO 15693 data carriers can operate with the lock.
-
The data carrier can have a GANTNER locker segment, however the segment is not used for this mode.
-
When a locker is locked with a data carrier, the locker number is not written onto the data carrier.
-
Every data carrier can use (lock) any number of lockers at the same time.
Locking and unlocking lockers
► Close the locker door and hold it shut.
► Hold the data carrier next to the RFID reading field.
o
The information on the data carrier is read.
► a) Valid data carriers: The LED flashes green briefly and the locking action is carried out.
b) Invalid data carriers: The LED flashes red briefly and the GAT ECO.Side Lock 7000 BA does not complete
the locking action.
► Release the locker door.
Personal Locker Programming Card Mode
For lockers operating in “personal locker programming card” mode, up to 32 data carriers per GAT ECO.Side Lock
7000 BA can be authorized for use. The data carriers can be used with the locker as often as required and share
the same authorization access, e.g., family cards.
The data carriers are authorized for use with the personal locker using the PROGRAM data carrier (included in the
GAT ECO.Basic Set B BA
, see section “6.4. GAT ECO.Basic Set B BA”).
Authorizing data carriers
► Close the locker door and hold it shut.
► Hold the PROGRAM data carrier next to the RFID reading field.
o
The information on the data carrier is read.
► The GAT ECO.Side Lock 7000 BA enters into programming mode.
o
The LED flashes red until the PROGRAM data carrier is removed. As soon as the PROGRAM data
carrier is removed, the LED flashes red/green and the lock is ready to program data carriers.
► Within 5 seconds, hold the data carrier to be authorized next to the reading field.
► a) Successful authorization: The LED flashes green for approximately 3 seconds. When the data carrier is
removed, the LED flashes green and red alternately again and another data carrier can be authorized in the
same way. Repeat this process until all the data carriers are authorized.
b) Unsuccessful authorization: The LED flashes red three times then the GAT ECO.Side Lock 7000 BA
switches off. Possible reasons for this include:
- The maximum of 32 data carriers are already authorized for use with the lock.
- The data carrier was not read by the lock correctly, e.g., the data carrier is damaged.
You can repeat the last step using different data carriers to program these data carriers successively. To do this,
hold the data carrier next to the reading field within 5 seconds after removing the previous data carrier. If you wait
longer than 5 seconds, the reading process is terminated, and the read data carriers are saved in the lock.