GAT ECO.Side Lock 7000 BA / NW BA
Operation
www.gantner.com
HB_GAT-GAT-ECOSide-Lock7000-BA--EN_14
53
Deleting (removing authorization) data carriers
When deleting data carriers authorized to use a personal locker, it is only possible to delete all data carriers in the
GAT ECO.Side Lock 7000 BA at once.
► Close the locker door and hold it shut.
► Hold the PROGRAM data carrier next to the RFID reading field.
o
The information on the data carrier is read.
► The GAT ECO.Side Lock 7000 BA enters into programming mode.
o
The LED flashes red until the PROGRAM data carrier is removed. As soon as the PROGRAM data
carrier is removed, the LED flashes red/green and the lock is ready for the next step.
► Within 5 seconds, hold the PROGRAM data carrier next to the reading field again.
► If the action is successful, the LED flashes red 3 times and the GAT ECO.Side Lock 7000 BA switches off.
o
All data carriers are now deleted from the lock and cannot use the locker any more.
Personal Locker Expiry Date Mode
During check-in, the guest receives a data carrier encoded with GANTNER data blocks. The FID is written onto the
“general” data block and the guest’s personal locker number together with the expiry date ("valid from" and "valid
to") are written onto the “locker” data block of the data carrier. Furthermore, an index value is written onto the
“locker” data block. The "valid from" date must always be valid, i.e., newer or equal to the date set in the GAT
ECO.Side Lock 7000 BA.
Upon first use of a locker, the expiry date ("valid to" date) and the current index value of the data carrier are stored
in the lock. The guest can lock and unlock the locker as required, starting from the "valid from" date and for as long
as the expiry date is not reached or exceeded.
NOTE!
The GAT ECO.Side Lock 7000 BA does not adjust to daylight saving time automatically. This must be
considered when evaluating events and authorizing data carriers with an expiry date.
An unlimited number of data carriers (people) can use the same locker. The following conditions apply to the data
carriers in this mode:
-
The same locker number must be stored on the data carriers.
-
The same expiry date must be stored on the data carriers.
-
The same index value must be stored on the data carriers.
When one of the data carriers assigned to a guest is used at the locker for the first time, the expiry date and the
index value of the data carrier is written onto the locker.