GAT ECO.Side Lock 7000 BA / NW BA
Operation
www.gantner.com
HB_GAT-GAT-ECOSide-Lock7000-BA--EN_14
55
6.4 GAT ECO.Basic Set B BA
The following items are included in the GAT ECO.Basic Set B BA (Part No. 958131).
System data carriers:
-
MASTER data carrier (3 pieces, red)
-
OPEN MASTER data carrier (optional)
-
DELETE MASTER data carrier (orange) / formerly RESET data carrier (green)
-
PROGRAM data carrier (black)
-
BATTERY data carrier (blue)
-
SERVICE data carrier (yellow)
-
Battery cover key for the GAT ECO.Side Lock 7000 (NW) BA with BATTERY data carrier functionality.
Additional items:
-
3 m USB programming cable
-
GANTNER USB stick with configuration software
-
GANTNER lanyard
6.5 Summary of System Data Carriers
The data carriers included in the GAT ECO.Basic Set B BA are required to configure and maintain a GAT ECO.Side
Lock 7000 BA locker system.
The system data carriers are coded to function with specific installations and will only function with the respective
system.
MASTER Data Carrier
MASTER data carriers can lock and unlock any GAT ECO.Side Lock 7000 BA
in a system. If a user’s data carrier is
lost, an emergency opening of the corresponding locker can be carried out using a MASTER data carrier. Three
MASTER data carriers are included in the Basic Set and they are only valid for the respective system.
NOTE!
The system operator must ensure that the MASTER
data carriers are stored in a safe and secure location.
If a MASTER data carrier is lost, a replacement can be ordered from GANTNER Electronic GmbH. Before the new
MASTER data carrier is used, the original MASTER data carriers must be deleted from the GAT ECO.Side Lock
7000 BA (the number of a MASTER data carrier is stored in the lock the first time it is used). This is carried out
using the DELETE MASTER data carrier as follows:
► Close the locker door and hold it shut.
► Hold the DELETE MASTER data carrier next to the RFID reading field.
o
The information on the data carrier is read and the LED flashes red until the DELETE MASTER data
carrier is removed.
► Remove the DELETE MASTER data carrier from the reading field.
o
All MASTER data carriers are now deleted from the lock
o
The LED flashes green and red alternately and the new MASTER data carriers can be programmed.
Summary of Contents for GAT ECO.Side Lock 7000 BA