GAT ECO.Side Lock 7000 BA / NW BA
Operation
www.gantner.com
HB_GAT-GAT-ECOSide-Lock7000-BA--EN_14
57
BATTERY Data Carrier
After the battery is replaced in the GAT ECO.Side Lock 7000 BA, the lock is in battery replacement mode and must
be returned to the normal operating mode using the BATTERY data carrier. The internal action counter is reset to
zero when the BATTERY data car
rier is used. See section “4.2.3. Replacing the Battery” for more information.
After replacing the batteries of a GAT ECO.Side Lock 7000 BA in personal locker mode, all settings stored in
the lock remain as previously configured.
SERVICE Data Carrier
The SERVICE data carrier is used to put the GAT ECO.Side Lock 7000 BA into configuration mode after the lock is
connected to a computer via USB (see section “4.3 USB Connection”). The settings of the GAT ECO.Side Lock
7000 BA are configured using GAT Config Manager while the lock is
in configuration mode (see chapter “5
When the GAT ECO.Side Lock 7000 BA reads the SERVICE data carrier without being connected to a PC via USB
cable, an antenna calibration is performed, which locks the lock for a few seconds. After locking, the LED flashes
red and the SERVICE data carrier must be removed. The antenna is calibrated and the LED flashes green. Finally,
a green LED and sound signal are emitted to indicate that the antenna calibration has been performed successfully.
The locker is then unlocked if it was locked before the calibration.
NOTE!
The SERVICE data carrier must be available for technicians who are required to configure the locker
system. Without the SERVICE data carrier, system configuration is not possible!
6.6 Alarm and Handling
The GAT ECO.Side Lock 7000 BA is designed to detect when somebody attempts to force open a locker door. To
alert facility staff to the break-in, a loud, intermittent alarm signal is activated and the status LED flashes red.
Upon delivery, the GAT ECO.Side Lock 7000 BA alarm function is deactiva
ted. See section “5.6.4. Alarm
” for information on how to activate the function.
To deactivate a locker alarm:
► Close the locker door and hold it shut.
► Hold a MASTER data carrier next to the RFID reading field (see section “6.5.1. MASTER Data Carrier”).
o
The alarm sound signal is deactivated and the LED stops flashing.
► If the locker door is still locked, hold a MASTER data carrier or the data carrier previously used to lock the
locker next to the RFID reading field.
o
The locker door opens.
NOTE!
The GAT ECO.Side Lock 7000 BA, bolt set, and door shackle must all be replaced following a break-in.