GAT ECO.Side Lock 7000 BA / NW BA
Cleaning and Maintenance
60
HB_GAT-GAT-ECOSide-Lock7000-BA--EN_14
www.gantner.com
► Hold an authorized data carrier a distance of approximately 1 cm in front of the locker door.
o
The locker door must unlock and spring open independently. If the door does not spring open by itself,
the door must be readjusted (see below). If the data carrier is not read at this distance, the RFID
reading field is possibly misaligned and require recalibration
”).
Adjusting the locker door and door bolt
Should a problem, as described previously
in “Instructions”, occurs while opening or closing the locker door during
functional testing:
► Adjust the position of the GAT NET.Lock Bolt Set or the door shackle according to the measurements in
chapter "3 INSTALLATION" (depending on the locker material used). If the door shackle is loose and does not
remain in the adjusted position or cannot be adjusted sufficiently, the GAT NET.Lock Bolt Set must be
replaced.
► Adjust the position of the locker door according to the measurements in chapter "3 INSTALLATION". If the door
cannot be adjusted sufficiently, install it in a different position. If the door is damaged, replace the door with a
new door.
7.3 Cleaning
Regular cleaning of the locker components ensures that the locker system remains in good condition and the
correct working order is maintained.
NOTE!
Do not use cleaning benzene, diluents, or other abrasive detergents. In addition, the components must not
be cleaned using high-pressure or steam cleaning equipment otherwise they can become damaged!
Complete the following steps to clean the locker:
► Wipe off dirt and dust using a soft, lint-free, dry cloth.
► For extreme dirt, clean the locker components using a slightly moistened cloth. Do not allow moisture to enter
the inner parts of the lock or the controller.
7.4 Maintenance
The GAT ECO.Side Lock 7000 BA system components are maintenance-free, i.e., regular maintenance of the
mechanical parts is not required. Should a malfunction be detected during functional testing that cannot be
remedied, the corresponding faulty part(s) must be replaced.
Summary of Contents for GAT ECO.Side Lock 7000 BA
Page 63: ......