GAT ECO.Side Lock 7000 BA / NW BA
Configuration
44
HB_GAT-GAT-ECOSide-Lock7000-BA--EN_14
www.gantner.com
5.6 Configuration Settings of the GAT ECO.Side Lock 7000 BA
The main configuration settings of the GAT ECO.Side Lock 7000 BA that can be adjusted in GAT Config Manager
are explained in this section. A list and brief explanation of every configuration setting available for the GAT ECO.Side
Lock 7000 BA can be found in section “5.6.9 Configuration Settings Table”.
Operating Mode
The GAT ECO.Side Lock 7000 BA can operate in one of
five different operating modes. See “6.3 Operating Modes”
for a detailed description of each mode. The operating mode setting is found here:
Configuration > Operating mode > General > Operating mode
► From the “Operating mode” drop-down menu, select either:
-
“Free locker”,
-
“Free locker universal”,
-
“Personal locker programming card”,
-
“Personal locker expiry date”, or,
-
“Free locker unique number”
Locker Number
The number of the locker where the GAT ECO.Side Lock 7000 BA is installed can be defined. The locker number
setting is found here:
Configuration > Operating mode > General > Locker number
► Enter the locker number for the GAT ECO.Side Lock 7000 BA into the “Locker number” field.
Sound Signals
The GAT ECO.Side Lock 7000 BA has an integrated beeper that signals when locker activity takes place. The
sound signals setting is found here:
Configuration
>
Operating mode
>
General
>
Beeper mode
► Select / deselect the “Beeper mode” option to turn the sound signals on / off.
NOTE!
When deactivated, the sound signals are still activated when an alarm is triggered and when the GAT
ECO.Side Lock 7000 BA is used with system data carriers, e.g., unlocked using a MASTER data carrier.
Alarm Mode
The GAT ECO.Side Lock 7000 BA is designed to detect when somebody attempts to force open a locker door. The
lock emits a loud, intermittent alarm tone and the status LED flashes red when an alarm is triggered. The alarm
mode function is found here:
Configuration
>
Operating mode
>
General
>
Alarm mode
► Select / deselect the “Alarm mode” option to turn the function on / off.
Summary of Contents for GAT ECO.Side Lock 7000 BA