Auto-Unlock
The auto-unlock function automatically unlocks the GAT ECO.Side Lock 7000 BA at a defined point in time. The time
must be set correctly once via software.
NOTE!
When this function is activated, the lock will always unlock at the defined point of time regardless of the
operating mode (see “6.3 Operating Modes”).
The auto-unlock function is found here:
Configuration > Operating mode > General > AutoUnlock [min]
► Enter a value representing the number of minutes into the field. The countdown time for unlocking begins at
00:00 (24 h). For example, a value
of “300” means that the lock will unlock at 05:00 am. A value of “0” means
that the function is inactive.
Duration of Use
Lockers operating in free locker mode can be configured to restrict users to a defined usage period
. See section “6.3.1
Free Locker Mode (with or without Duration of Use Function)
” for more information. The duration of use function is
found here:
Configuration > Operating mode > Free Locker
► Select either “Duration” or “Point of time” from the “Use time limit” menu for the type of time limit.
► Define the time limit in minutes in the “Time limit (min)” field.
Locking of Personal Locker without data carrier
The functionality of locking personal lockers without data carriers allows the locker to lock automatically when the
locker door is pushed shut, without needing to use a data carrier. The locker can be unlocked again using the data
carrier(s) authorized to use the personal locker. The function is found here:
Configuration > Operating mode > Personal Locker > PreLock Personal Locker
► Select / deselect the “PreLock Personal Locker” option to turn the function on / off.
MASTER Data Carriers
Up to 10 MASTER data carriers (usually in card format) can be assigned to the GAT ECO.Side Lock 7000 BA to allow
the locker to be opened in special circumstances, e.g., when a user has lost their data carrier. For this functionality,
the MASTER data carriers must be first assigned to the GAT ECO.Lock 7xxx F/ISO, which is done here:
Configuration > Application > Master cards > Master Card 1 - 10
► Enter the number of each MASTER data carrier into the respective fields.
NOTE!
The numbers of the MASTER data carriers must be entered in hexadecimal format.
There is also an OPEN MASTER data carrier available (not included in the Basic Set). This special data carrier
can open all lockers (like the MASTER data carriers) but cannot close the lockers. It is possible to program an
OPEN MASTER data carrier by entering the number of the OPEN MASTER data carrier in one of the 10 fields.
In this case only 9 MASTER data carriers can be used.