Deleting (removing authorization) data carriers 
 
When deleting data carriers authorized to use a personal locker, it is only possible to delete all data carriers in the 
GAT ECO.Side Lock 7010 F/ISO at once. 
 
►  Close the locker door and hold it shut. 
►  Hold the PROGRAM data carrier next to the RFID reading field. 

o

  The information on the data carrier is read. 

►  The GAT ECO.Side Lock 7010 F/ISO enters into programming mode. 

o

  The LED flashes red until the PROGRAM data carrier is removed. As soon as the PROGRAM data 

carrier is removed, the LED flashes red/green and the lock is ready for the next step. 

►  Within 5 seconds, hold the PROGRAM data carrier next to the reading field again. 
►  If the action is successful, the LED flashes red 3 times and the GAT ECO.Side Lock 7010 F/ISO switches off. 

o

  All data carriers are now deleted from the lock and cannot use the locker any more. 

 
 
 

6.3.5 

Personal Locker Expiry Date Mode 

 

During check-in, the guest receives a data carrier encoded with GANTNER data blocks. The FID is written onto the 
“general” data block and the guest’s personal locker number together with the expiry date ("valid from" and "valid to") 
are written onto the “locker” data block of the data carrier. Furthermore, an index value is written onto the “locker” 
data block. The "valid from" date must always be valid, i.e., newer or equal to the date set in the GAT ECO.Side Lock 
7010 F/ISO. 
 

 

Upon first use of a locker, the expiry date ("valid to" date) and the current index value of the data carrier are stored in 
the lock. The guest can lock and unlock the locker as required, starting from the "valid from" date and for as long as 
the expiry date is not reached or exceeded.  
 

NOTE!

 The GAT ECO.Side Lock 7010  F/ISO

 

does not adjust to daylight saving time automatically. This must be 

considered when evaluating events and authorizing data carriers with an expiry date. 
 
An unlimited number of data carriers (people) can use the same locker. The following  conditions apply to the data 
carriers in this mode:  

The same locker number must be stored on the data carriers. 

The same expiry date must be stored on the data carriers. 

The same index value must be stored on the data carriers. 

 
When one of the data carriers assigned to a guest is used at the locker for the first time, the expiry date and the index 
value of the data carrier is written onto the locker. 

 

Summary of Contents for GAT ECO.Side Lock 7010 F/ISO

Page 1: ...www gantner com HB_GAT ECOSide Lock7010 FISO EN_11 1 GAT ECO Side Lock 7010 NW F ISO Battery Powered Multi Technology Electronic Lock Installation Configuration Operation Document Version 1 1...

Page 2: ...the guarantee Any further reaching claims are excluded and in particular the manufacturer accepts no liability for the completeness or accuracy of the contents of this manual The right is reserved to...

Page 3: ...ls intended to inform the user about potentially hazardous situations or important information for the safe and proper use of the described product s The safety messages also include directives on how...

Page 4: ...Signal Words Indicates a hazardous situation that if not avoided may result in minor or moderate injury Indicates information considered important but not hazard related e g messages relating to prop...

Page 5: ...ce of the product must be carried out in accordance with the technical conditions of operation as described in the corresponding documentation Therefore it is essential to read the corresponding chapt...

Page 6: ...requency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur...

Page 7: ...0 F ISO and GAT NET Lock Bolt Sets 20 3 10 Installation in Lockers with Non Metallic Doors except glass 22 3 10 1Installation Requirements for the GAT ECO Side Lock 7010 F ISO and Bolt Set 23 3 10 2In...

Page 8: ...10Configuration Settings Table 47 6 OPERATION 49 6 1 General 49 6 2 Target Group 49 6 3 Operating Modes 49 6 3 1 Free Locker Mode with or without Duration of Use Function 50 6 3 2 Free Locker Universa...

Page 9: ...k 7010 F ISO into lockers with metallic non metallic and glass doors Chapter 4 COMMISSIONING describes how to put the GAT ECO Side Lock 7010 F ISO into operation and includes information on the batter...

Page 10: ...asks risk personal injury or damaging property equipment 1 5 Formatting 1 5 1 Safety Critical Information The following formatting with example text is used in this manual to display important safety...

Page 11: ...and for glass locker doors the GAT NET Lock BoltSet 7300 is available The bolt sets include a passive booster used to amplify the RFID reading field The GAT ECO Side Lock 7010 F ISO is powered by one...

Page 12: ...needed FID Company ID and Site Key The FID and site key are unique numbers assigned to every facility installation The site key is a combination of the FID and the read and write keys The site key is...

Page 13: ...gy the device supports F MIFARE ISO ISO 15693 The GAT ECO Side Lock 7010 F ISO has a multi technology RFID reader that allows it to operate with a range of RFID technologies The information in this ma...

Page 14: ...e GAT ECO Side Lock 7010 system 1 GAT ECO Side Lock 7010 NW F ISO 2 GAT NET Lock BoltSet 7100 3 GAT NET Lock BoltSet 7200 5 GAT NET Lock Tool 7000 6 GAT NET Lock Label GEA xxx Door labels in different...

Page 15: ...the locker door 6 GAT NET Lock Label 7000 GEA xxx Self adhesive locker door labels in GANTNER design For metallic doors the label is stuck onto the label carrier For non metallic doors the label is s...

Page 16: ...GAT ECO Side Lock 7010 NW F ISO General Information 16 HB_GAT ECOSide Lock7010 FISO EN_11 www gantner com...

Page 17: ...rmation for technicians who install the GAT ECO Side Lock 7010 F ISO Experience in mechanical work and basic electrical knowledge is required Previous knowledge of the GAT ECO Side Lock 7010 F ISO is...

Page 18: ...ay An installation checklist is available from GANTNER to assist with the test installation process 3 4 Metallic and Non Metallic Doors Because the RFID field of the GAT ECO Side Lock 7010 F ISO is di...

Page 19: ...sportation Guidelines The electronics of the GAT ECO Side Lock 7010 F ISO are activated when the locker door is pressed shut For factory produced lockers that use the GAT ECO Side Lock 7010 F ISO it i...

Page 20: ...width allowed measured from the door shackle to the hinge is 230 mm 9 05 If the door is narrower the door shackle will hit the locker when the door is being closed Figure 3 4 Minimum door width 3 9 2...

Page 21: ...mm inches in brackets Figure 3 7 Dimensions of the GAT NET Lock BoltSet 7200 dimensions in mm inches in brackets Figure 3 8 Dimensions of the GAT NET Lock BoltSet 7300 dimensions in mm inches in brack...

Page 22: ...of the locker door A drill hole is required in the locker door for the status LED See the diagram below and the following installation instructions For glass door installation instructions see 3 12 I...

Page 23: ...nd the front side of the GAT ECO Side Lock 7010 F ISO must be perpendicular and parallel to each other If not the door contact in the GAT ECO Side Lock 7010 F ISO can potentially not function correctl...

Page 24: ...entation and snaps onto the lock Close the door so that the center points on the bolt gauge mark the hole positions onto the locker door inner side NOTE For doors made of softer material moderate pres...

Page 25: ...sheet and one in the outer door sheet The two parts of the GAT NET Lock Bolt Set 7200 are then mounted into the locker door See the diagram below and the following installation instructions 1 GAT ECO...

Page 26: ...outs in the Locker Door The following cutouts must be made on the inner and outer walls of the locker door in order to mount the GAT NET Lock BoltSet 7200 and label carrier The measurements for the cu...

Page 27: ...surement in Figure 3 11 The locker door the bolt set and the front side of the GAT ECO Side Lock 7010 F ISO must be perpendicular and parallel to each other If not the door contact in the GAT ECO Side...

Page 28: ...a section 67 6 mm x 94 mm 2 66 x 3 7 in the outer wall of the locker door for the label carrier 9 in Figure 3 12 Mount the bolt set onto the inside wall of the locker door using 4 screws NOTE Use pan...

Page 29: ...he locker door Furthermore a recess in the printing on the locker door or door label may be necessary for the status LED See the diagram below and the following installation instructions 1 GAT ECO Sid...

Page 30: ...nd the front side of the GAT ECO Side Lock 7010 F ISO must be perpendicular and parallel to each other If not the door contact in the GAT ECO Side Lock 7010 F ISO can potentially not function correctl...

Page 31: ...47 lb ft Use glass adhesive to attach the GAT NET Lock BoltSet 7300 in the correct position to the inside of the glass door Observe the information in section 3 12 1 Installation Requirements for the...

Page 32: ...GAT ECO Side Lock 7010 NW F ISO Installation 32 HB_GAT ECOSide Lock7010 FISO EN_11 www gantner com...

Page 33: ...locking cycles usage frequency of the lock and the environmental conditions The battery must be replaced when the battery voltage becomes too low If the battery becomes too weak the locker can no long...

Page 34: ...y been used and the battery is being replaced the lock must be activated using the Battery data carrier see 4 2 3 Replacing the Battery After inserting the battery the GAT ECO Side Lock 7010 F ISO is...

Page 35: ...carrier next to the RFID reading field o The internal counter in the GAT ECO Side Lock 7010 F ISO is reset and the lock returns to its normal operating mode 4 3 USB Connection A Micro B USB port is pr...

Page 36: ...for the first time the lock drivers are installed and the lock is automatically recognized If a driver is requested they are available on the Leisure Software USB stick which is included in the GAT EC...

Page 37: ...er immediately after activating the antenna adjustment o The antenna adjustment process begins and the status LED flashes red for 5 seconds The process is complete when the LED flashes green for 1 sec...

Page 38: ...GAT ECO Side Lock 7010 NW F ISO Commissioning 38 HB_GAT ECOSide Lock7010 FISO EN_11 www gantner com...

Page 39: ...sal free locker unique number personal locker programming card or personal locker expiry date See section 6 3 Operating Modes Free Locker Sector number of the data on the data carrier and the time set...

Page 40: ...existing project Alternatively click on the Create Project icon 2 in Figure 5 1 to start a new project Figure 5 1 GAT Config Manager project setup Once a project is established locations and sub loca...

Page 41: ...nected GAT ECO Side Lock 7010 F ISO has been added to the Devices directory you can now view and adjust the configuration settings of the lock Complete the following steps to view the configuration se...

Page 42: ...Side Lock 7010 F ISO When you are finished configuring the GAT ECO Side Lock 7010 F ISO settings in GAT Config Manager it is important to finalize the configuration by uploading the file to the lock C...

Page 43: ...lar intervals Right click onto the GAT ECO Side Lock 7000 in the Devices tree and select Update Firmware Figure 5 6 Updating the GAT ECO Side Lock 7010 F ISO firmware o The Device update wizard opens...

Page 44: ...oLA app is currently not available on Apple devices In MoLA you can change the same configuration settings like in GAT Config Manager see 5 3 Configuration with the MoLA App A detailed description abo...

Page 45: ...number of the locker where the GAT ECO Side Lock 7010 F ISO is installed can be defined The locker number setting is found here Configuration Operating mode General Locker number Enter the locker numb...

Page 46: ...e Free Locker Select either Duration or Point of time from the Use time limit menu for the type of time limit Define the time limit in minutes in the Time limit min field 5 4 7 Locking of Personal Loc...

Page 47: ...r FreeLockerUniversal List option Free Locker Locker number Enter the locker number here Integer 30000 Beeper mode Switch on off the lock sound signal function Boolean True Alarm mode Switch on off th...

Page 48: ...pe of file Standard Backup List option ISO 15693 Options for reading ISO 15693 data carriers General Block Num The segment where general data is stored Integer 13 Certificate Block Num The segment whe...

Page 49: ...ating Modes The GAT ECO Side Lock 7010 F ISO can function in one of the following operating modes Free locker with or without duration of use function NOTE The duration of use function for Free Locker...

Page 50: ...no longer unlock the locker In this case the user must release their data carrier at an Info Terminal e g a GAT Info 6100 F part no 776891 or a GAT Info 6800 F part no 765687 NOTE This function is on...

Page 51: ...and the locker cannot be opened anymore In this case the data carrier must be reset at a central station Release the locker door 6 3 2 Free Locker Universal Mode Free locker universal operating mode...

Page 52: ...ersonal locker using the PROGRAM data carrier included in the GAT ECO Basic Set F ISO see section 6 4 GAT ECO Basic Set F ISO Authorizing data carriers Close the locker door and hold it shut Hold the...

Page 53: ...the general data block and the guest s personal locker number together with the expiry date valid from and valid to are written onto the locker data block of the data carrier Furthermore an index val...

Page 54: ...ized data carriers are no longer authorized to use the locker 4 has the same index value and a newer valid to date than in the lock o The index value and the new valid to date of the data carrier are...

Page 55: ...th specific installations and will only function with the respective system 6 5 1 MASTER Data Carriers MASTER data carriers can lock and unlock any GAT ECO Side Lock 7010 F ISO in a system If a user s...

Page 56: ...carrier the OPEN MASTER data carrier can only unlock a locker but cannot lock the locker The OPEN MASTER data carrier is not included in the Basic Set and must be ordered separately if required This...

Page 57: ...de Lock 7010 F ISO reads the SERVICE data carrier without being connected to a PC via USB cable an antenna calibration is performed which locks the lock for a few seconds After locking the LED flashes...

Page 58: ...er previously used to lock the locker next to the RFID reading field o The locker door opens NOTE The GAT ECO Side Lock 7010 F ISO bolt set and door shackle must all be replaced following a break in 6...

Page 59: ...omponents Frequency After every 1000 locking operations or If the locking function of a locker door is impaired Instructions Press the locker door shut o The door shackle must enter the corresponding...

Page 60: ...olt Set must be replaced Adjust the position of the locker door according to the measurements in chapter 3 INSTALLATION If the door cannot be adjusted sufficiently install it in a different position I...

Page 61: ...pported types MIFARE Classic 1k and 4K MIFARE Ultralight DESFire EV1 and EV2 ISO 15693 HID read unique number Note It is recommended to have customer specific data carriers approved by GANTNER before...

Page 62: ...e connection USB type Micro B 8 7 Housing Material Plastic PC halogen free V0 Color Dark gray Weight Approx 400 g 14 1 oz Dimensions 125 2 mm x 100 mm x 25 mm 4 93 x 3 94 x 0 98 Break in resistance ca...

Page 63: ......

Page 64: ...16 T 61 29011 8114 info gantner com info gantner nl info aus gantner com London GB Bochum Germany Los Angeles USA T 44 1245 697588 T 49 234 58896 0 T 1 844 703 1139 info uk gantner com info de gantne...

Reviews: