GAT NET.Lock 7000 System
Mounting
www.gantner.com
HB_GAT-NETLOCK7000--EN_30
19
3.6.1 Cut-Outs in the Locker Door
On the inside and outside walls of the locker door the following cut-outs must be made in order to mount the GAT
NET. Lock BoltSet 7200 and the label carrier. The measurements for the cut-outs are as follows.
Figure 3.8
- Cut-Outs in Metallic Doors
3.6.2 Important Measures when Mounting the GAT NET.Lock 7000 and Bolt Set (Metal Doors)
During the mounting, please pay particular attention to the following points:
- The door thickness must be between 18 and 26 mm (see Figure 3.7).
- When the door is pressed shut, the gap between the bolt set and the front of the GAT NET.Lock 7000 must not
exceed 0.5 mm (see measure in Figure 3.7). Ideally the bolt set should touch the front of the lock.
- The middle of the door shackle (4) must be 1 mm higher than the middle of the door shackle opening in the GAT
NET.Lock 7000 (see measure in Figure 3.7)
. This ensures the door’s ability to close even if the door position is
modified 3 mm downwards or 1 mm upwards (tolerance ±2 mm).
Before mounting all locks of the locker system a test installation of one lock in a mechanically finalized locker
and a subsequent function check must be performed like described below. Only if this check is successful,
the rest of the locks may be mounted in the same way!