GAT NET.Lock 7000 System
Mounting
20
HB_GAT-NETLOCK7000--EN_30
www.gantner.com
3.6.3 Steps for Mounting of the GAT NET.Lock 7000 at Metallic Doors
Please perform the following steps in order to mount the GAT NET.Lock 7000 at metallic doors.
Drill the 3 holes (3) for the GAT NET.Lock 7000 into the locker wall.
Attention:
Position the 3 holes according to the information in the previous section "3.5.1. Important Measures
when Mounting the GAT NET.Lock 7000 and Bolt Set (Non-Metal Doors)"!
Plug-in the connection cable at the GAT NET.Lock 7000 (see "4. Electrical Connection").
Mount the GAT NET.Lock 7000 with 3 screws (3) on the inside locker wall.
Note:
Use the right screws according to the type of locker material
Attention:
The max. allowed tightening torque of the screws is 2 Nm.
On the inner wall of the locker door make the cut-out (63.2 x 68 mm) for the GAT NET.Lock Bolt Set 7200.
On the inner wall of the locker door drill the 4 holes (6) for mounting the GAT NET.Lock Bolt Set 7200.
On the outer wall of the locker door make the cut-out (68.2 x 94 mm) for the label carrier.
Mount the bolt set onto the inside wall of the locker door by using the 4 screws included in the scope of supply (Torx Ø
3.5 x 9.5 mm) as shown in Figure 3.8 on the previous page.
Note:
Use the following screws (which are included in the scope of supply): Torx, Ø 3.5 mm, length 9.5 mm
Push the label carrier onto the outside wall of the locker door. The label carrier will hold in place with the lashes on
the label carrier - no screws are required.
Stick the front label onto the label carrier.
Note:
A customer-specific front label can be used to cover the LED hole. A transparent field should be placed on
the label to show the LED light
Figure 3.9
- Label carrier with front label
Close the door to test, if the locker door can be closed easily and the door shackle inserts into the opening in the
GAT NET.Lock 7000.