GAT NET.Lock 7000 System
Technical Data
www.gantner.com
HB_GAT-NETLOCK7000--EN_30
37
6. TECHNICAL DATA
6.1 GAT NET.Lock 7000
Nominal voltage U
DC
:
5 V
Power supply:
Via connection cable from the slave controller
Average power consumption:
60 mW
RFID frequency:
13.56 MHz
Retaining force:
Min. 1,500 N
Force on inner side of the door:
Max. 100 N
User guidance:
Multi-colour status LED
Interface:
One-wire (special cable for supply, data and RF signal)
Number of locks per slave controller:
24
Connectors:
MOLEX, type Micro-
Fit 3.0™
Housing material:
Plastic (PC)
Door width:
Min. 230 mm
Dimensions:
110 x 100 x 25 mm
Permitted ambient temperature:
0 to +60 °C
Protection type:
IP 52
Protection class:
III
Weight:
Approx. 160 g
Environment class based on VDS 2110:
II (conditions in indoor areas)
6.2 GAT NET.Controller S 7000
Nominal voltage U
DC
:
24 V
Power supply unit:
External power supply units (use only power supply units approved by GANT-
NER Electronic GmbH for the GAT NET.Controller 7000)
Average power consumption:
-
Reader types
- GAT NET.Controller S 7000 F/ISO:
MIFARE
™ + ISO 15693
- GAT NET.Controller S 7000 B:
LEGIC
®
(Advant)
Number of locks per slave controller:
24
GAT Lock Network:
Max. 8 slave controllers GAT NET.Controller S 7000 at one master con-
troller GAT NET.Controller M 7000
Interface to the locks:
1 Wire (special cable for supply and data signal)
Interface between slave and master:
RS 485
Connectors:
- Slave to master (RS 485): RJ 45
- Locks: MOLEX, type Micro-
Fit 3.0™
- Supply: MOLEX
Housing material:
Plastic (ABS)
Dimensions:
310 x 133 x 42 mm (12.2 x 5.24 x 1.65 inch)
Permitted ambient temperature:
0 to +60 °C
Protection type:
IP 40
Protection class:
I
Weight:
Approx. 600 g
Environment class based on VDS 2110:
II (conditions in indoor areas)