The GAT NET.Lock 7000 system consists of the following system parts: 
             
 

 

 
 
 
 
 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 
 
 
 
 
 
 
 
 
 

 
 

Figure 2.1 

 - System parts of the GAT NET.Lock 7000 system 

12.  Ethernet Patch Cable 

4.  GAT NET.Controller S 7000 

(Slave Controller) 

11.  GAT NET.Lock Connector 
 

Coupling for cable con-
nection 

6.  GAT NET.Power Supply 230V EU 
 

Power Supply Unit 

7.  GAT NET.Power Plug 

5.  GAT NET.Controller M 7000 

(Master Controller) 

1.  GAT NET.Lock 7000 

2.  GAT NET.Lock BoltSet 7100 

(for non-metallic doors) 

10.  GAT NET.Lock Cable 4m 
 

(connection cable, 

 

length 4 m) 

3.  GAT NET.Lock BoltSet 7200 
 

(for metallic doors, includes the 
label carrier) 

9.  GAT NET.Lock Label GEA right 
 

GAT NET.Lock Label GEA NUM right 

 

GAT NET.Lock Label GEA left 

 

GAT NET.Lock Label GEA NUM left 

 

(Front labels in different variants) 

8.  GAT NET.Lock Tool 7000 
 

(Center punch gauge for 
bolt mounting) 

13.  GAT NET.Lock Basic Set B 
 

GAT NET.Lock Basic Set F 

 

GAT NET.Lock Basic Set ISO 

 

(Five master cards and an as-
sumption of liability sheet) 

 

Summary of Contents for GAT NET.Lock 7000

Page 1: ...www gantner com HB_GAT NETLOCK7000 EN_30 1 GAT NET Lock 7000 System Electronic RFID Locker Locks Installation Configuration Operation Document Version 3 0...

Page 2: ...GAT NET Lock 7000 System 2 HB_GAT NETLOCK7000 EN_30 www gantner com...

Page 3: ...s case contact your customer advisor He will make every effort to resolve the problem as quickly as possible 7 Installation commissioning and servicing of our appliances must only be carried out by su...

Page 4: ...y we still look forward to hear from you We wish you a successful application of our appliances We will be pleased to welcome you as a customer again soon Contact address manufacturer GANTNER Electron...

Page 5: ...00 at Metallic Doors 20 3 7 Points to be observed during Installation 21 3 8 Test Installation 21 3 9 Replacement after a Burglary Attempt 21 4 Electrical Connection 23 4 1 System Structure 23 4 2 Cab...

Page 6: ...6 HB_GAT NETLOCK7000 EN_30 www gantner com 5 6 GAT Relaxx Operation Software for GAT NET Lock 7000 System 34 5 6 1 User Interface 34 6 Technical Data 37 6 1 GAT NET Lock 7000 37 6 2 GAT NET Controller...

Page 7: ...mounting procedure of the locks and bolt sets with all important measures and information can be found Because there are many different types of lockers available the mounting procedure is written in...

Page 8: ...t 7 GAT NET Power Plug 5 GAT NET Controller M 7000 Master Controller 1 GAT NET Lock 7000 2 GAT NET Lock BoltSet 7100 for non metallic doors 10 GAT NET Lock Cable 4m connection cable length 4 m 3 GAT N...

Page 9: ...T Controller S 7000 8 GAT NET Lock Tool 7000 Center punch gauge for bolt mounting in the locker doors With these gauges the drillings for the mounting can be easily marked on the locker doors 9 GAT NE...

Page 10: ...GAT NET Lock 7000 System General Information 10 HB_GAT NETLOCK7000 EN_30 www gantner com...

Page 11: ...tware from GANTNER Electronic GmbH on a host computer server Using a locker The user closes the door of a free locker and while holding the door shut puts his data carrier onto the reading centre at t...

Page 12: ...rs The bolt sets for the GAT NET Lock 7000 already include boosters 1 in the GAT NET Lock BoltSet 7100 for non metallic doors and 2 in the GAT NET Lock BoltSet 7200 for metallic doors GAT Relaxx PC so...

Page 13: ...of the opening direction of lockers left right In the following pages the mounting for right hinged doors is desribed The installation process for left locker doors is in principle the same as for ri...

Page 14: ...Mounting 3 3 1 Door Width The minimum door width allowed measured from the door shackle to the hinge is 230 mm If the door is narrower the door shackle would hit the locker when the door is being clo...

Page 15: ...oors 1 GAT NET Lock 7000 2 GAT NET Lock BoltSet 7100 for non metallic doors 3 GAT NET Lock BoltSet 7200 for metallic doors 4 Door shackle 5 Door contact 6 Booster 7 Status LED 8 Label carrier 3 4 Door...

Page 16: ...material 4 Door shackle 5 Door contact 6 Mounting screws for bolt set 7 LED hole in the locker door Figure 3 5 Mounting of the GAT NET Lock 7000 in a locker with non metallic door right door 3 5 1 Imp...

Page 17: ...he 3 holes according to the information in 3 5 1 Important Measures when Mounting the GAT NET Lock 7000 and Bolt Set Non Metal Doors Plug in the connection cable at the GAT NET Lock 7000 see 4 Electri...

Page 18: ...ide door sheet The two parts of the GAT NET Lock Bolt Set 7200 are then mounted into the locker door See the following figure and the steps afterwards for the mounting instructions 1 GAT NET Lock 7000...

Page 19: ...m see Figure 3 7 When the door is pressed shut the gap between the bolt set and the front of the GAT NET Lock 7000 must not exceed 0 5 mm see measure in Figure 3 7 Ideally the bolt set should touch th...

Page 20: ...8 mm for the GAT NET Lock Bolt Set 7200 On the inner wall of the locker door drill the 4 holes 6 for mounting the GAT NET Lock Bolt Set 7200 On the outer wall of the locker door make the cut out 68 2...

Page 21: ...rings or similar elements The locker door must open automatically without resistance when the GAT NET Lock 7000 unlocks the door 3 8 Test Installation As the GAT NET Lock 7000 is suitable for a wide r...

Page 22: ...GAT NET Lock 7000 System Mounting 22 HB_GAT NETLOCK7000 EN_30 www gantner com...

Page 23: ...e connection must only be done in powerless state and only by trained and specialised personnel 4 1 System Structure The GAT NET Lock 7000 are always connected to the slave controllers GAT NET Control...

Page 24: ...andard connection cable is too short it is possible to use two of those cables which are connected together with the GAT NET Lock Connector For connection of the GAT NET Lock 7000 only use an original...

Page 25: ...controller Therefore it is important where the locks are connected and how the locking system is configured The slave controller should be located in such a manner that the locks can be connected wit...

Page 26: ...RS 485 line length It is important to differentiate between the RS 485 IN and OUT plugs Connect the incoming cable from the master Controller or the previous slave controller to the RS 485 IN plug an...

Page 27: ...ower supply connections 1 The power supply can be connected to each slave controller individually 2 The power supply is connected to a single or a few slave controllers which in turn supply the remain...

Page 28: ...T NET Controller S 7000 LEDs RS 485 IN yellow The connection with the master controller has been established RS 485 IN green RS 485 communication is active LED 1 blue Lock activated controlled LED 2 g...

Page 29: ...ler M 7000 Note The RS 485 ADD ON connector is reserved for future requirements and must not be used to connect the slave controllers Observe the following values for the number of connectable control...

Page 30: ...LED Signals and Buttons For the display of the operating state and to start certain functions various LED indicators and buttons are provided on the GAT NET Controller M 7000 Figure 4 14 LEDs and butt...

Page 31: ...Locker In order to use an unused locker i e locking a locker the door must be pressed shut so that the door shackle moves into the GAT NET Lock 7000 While the door is kept shut the user must hold his...

Page 32: ...out 5 seconds The configuration parameters will remain un changed 5 4 Delete Configuration Parameters of a Controller Reset to Default Settings After deleting the configuration parameters of a control...

Page 33: ...r software green Normal operation connection to master controller and server software is OK alternately red green blinking Bootloader mode a firmware update is currently being loaded or there is no fi...

Page 34: ...the CD together with GAT Relaxx Furthermore the NET framework with version 4 0 or higher is required This is also included on the GAT Relaxx installation CD Installation and First Startup The GAT Rel...

Page 35: ...ew Here the hardware of the entire system is defined Communication channels and connected controllers can be added and the lockers used can be defined per con troller 6 Locker overview Here the locker...

Page 36: ...re based locker assignment to respective controllers 6 Locker overview Here the lockers of the selected area are displayed graphically The respecitve locker state is displayed by corresponding colours...

Page 37: ...indoor areas 6 2 GAT NET Controller S 7000 Nominal voltage UDC 24 V Power supply unit External power supply units use only power supply units approved by GANT NER Electronic GmbH for the GAT NET Cont...

Page 38: ...r memory expansion log files firmware update or person lists Digital inputs 4 x optocoupler Digital outputs 4 x relay Interface between slave and master RS 485 Interface between master and server Ethe...

Page 39: ......

Page 40: ...T 43 5556 73784 0 T 49 234 58896 0 T 61 2 9011 8114 F 43 5556 73784 8000 F 49 234 58896 11 F 61 2 8209 1708 info gantner com info de gantner com info aus gantner com GANTNER Electronics Ltd UK GANTNE...

Reviews: