3.2.4  Important Measurements for the Installation  

 
Please pay close attention to the following measurements: 
 

 

 

Figure 3.8

 

– Important measurements for the installation 

 

:  The centre of the door shackle must be 1 mm higher than the centre of the door shackle opening of the GAT 

SMART.Lock 7001. This enables the door to close correctly, even when the door’s position adjusts within the 
tolerance range of maximum 3.5 mm downwards or 1.5 mm upwards (tolerance ±2.5 mm). 

 

:  The  distance  between  the  front  surface  of  the  GAT  SMART.Lock  7001  and  the  distance  plate  must  be  1  to 

1.5mm when the locker door is closed. 

 

  

 

Figure 3.9

 - Distance between the front surface of the lock and the distance plate 

Summary of Contents for GAT SMART.Lock 7000 System

Page 1: ...www gantner com HB_GAT SMARTLOCK7000 EN_10 1 GAT SMART Lock 7000 System Electronic wired locking system W Installation Configuration Operation Document Version 1 0...

Page 2: ......

Page 3: ...ice In this case contact your GANTNER company representative The representative will make every ef fort to resolve the problem as quickly as possible 7 Installation commissioning and servicing of our...

Page 4: ...perfectly we still look forward to hearing from you We wish you a successful application of our product and look forward to welcoming you as a customer again soon Contact address manufacturer GANTNER...

Page 5: ...al Connection 25 4 1 System Structure 25 4 2 Cable Connection of the GAT SMART Lock 7001 26 4 2 1 Power Supply 26 4 2 2 Locking Return Message 26 4 3 Connection of the GAT SMART Controller S 7000 27 4...

Page 6: ...2 Open a Locker 47 6 2 GAT Relaxx Operating Software for GAT SMART Lock 7001 48 6 2 1 Software Licensing 48 6 2 2 User and Role Management 48 6 2 3 General and User Interface 48 7 Technical data 51 7...

Page 7: ...ntroller M 7000 control units a MOXA Com Converter or a central reader are required in ad dition to PC software for configuration and control of the locker system These system parts are also described...

Page 8: ...GAT SMART Lock 7000 System Introduction 8 HB_GAT SMARTLOCK7000 EN_10 www gantner com...

Page 9: ...T SMART LockAxx 6350 Central Reader 11 GAT NET Lock Connector Coupling for cable connection 8 GAT NET Power Plug 1 0 6 GAT NET Power Supply 230V EU Power Supply Unit 2 GAT SMART Lock 7000 Bolt Set Bol...

Page 10: ...T NET Power Cord XX Power cord for the GAT NET Power Supply 100 240V available in different versions XXX EU Euro plug UK UK AUS Australia US United States of America IND India 8 Power Plug Plug to sup...

Page 11: ...GAT SMART Lock 7000 System General Information www gantner com HB_GAT SMARTLOCK7000 EN_10 11...

Page 12: ...ding electronic RFID Radio Frequency Identification data carriers enabling system users to identify themselves with their data carriers The GAT SMART LockAxx 6350 operates online i e after reading a d...

Page 13: ...that controls the corresponding lock to unlock the locker for the user 2 5 Term Definitions Several terms are used often in this manual and are defined as described below Locker The term locker in thi...

Page 14: ...a carriers can be used by users for identification in order to unlock their lockers This can be done for example at a central reader Contactless RFID Radio Frequency Identification chips are used in d...

Page 15: ...ocks A test installation must be done before preparing the lockers and installing the locks see chapter 3 8 Test Installation Please also read the most important points for installation summarised in...

Page 16: ...e 6 Connection cable 7 Connection plug 8 Mounting safety emergency opening Figure 3 2 Mounting overview GAT SMART Lock 7001 for right hinged locker doors The GAT SMART Lock 7001 is fastened with 3 scr...

Page 17: ...Lock 7000 sys tem lock door shackle etc and other important dimensions that must be considered during installation Please read and observe this important measurement information before planning and st...

Page 18: ...r the length and diameter of the screws required for installation observe the length and diameter of the mounting holes shown in Figure 3 4 Figure 3 4 GAT SMART Lock 7001 3 2 3 Door Shackle and Mounti...

Page 19: ...ackle must be 1 mm higher than the centre of the door shackle opening of the GAT SMART Lock 7001 This enables the door to close correctly even when the door s position adjusts within the tolerance ran...

Page 20: ...GAT SMART Lock 7001 Re move the bolt after first completing the trial installation and functional testing see 3 6 Mounting Security Bolt Emergency Opening 3 4 Mounting the GAT SMART Lock 7001 in the L...

Page 21: ...ates onto the door see Figure 3 2 and Figure 3 6 while ob serving the vertical offset of 1 mm Insert the door shackle into the slot of the distance plate Figure 3 11 Door shackle and distance plate Fa...

Page 22: ...ckness of the door In assembled state the door bolt must guarantee a tensile force of 2000 N Note When fastening the door plate and the distance plate make sure that the heads of the screws sit com pl...

Page 23: ...ts to be Observed during Installation Fastening screws The GAT SMART Lock 7001 is fastened with three screws onto the locker wall Use the correct type of screws de pending on the type of locker materi...

Page 24: ...door shuts and locks correctly Attention When the GAT SMART Lock 7001 is closed and the mounting security bolt has already been removed the lock can only be unlocked by a corresponding signal emitted...

Page 25: ...ns are available to control lock un lock the individual GAT SMART Lock 7001 locks Lock functions can be controlled by a PC running system control software or via a central reader terminal where users...

Page 26: ...connection cable is too short an additional 4 m extension cable GAT NET Lock Cable 4m can be used To connect both cables use a GAT NET Lock Connector 4 2 1 Power Supply The GAT SMART Lock 7001 requir...

Page 27: ...s re spectively to configure the system accordingly afterwards The slave controller should be located so that the locks can be connected using cables of minimum length e g lo cated directly above the...

Page 28: ...length For the RS 485 connections the difference between the IN and OUT sockets must be observed Connect the in coming cable from the master controller or the previous slave controller to the RS 485 I...

Page 29: ...ower supply can be individually connected to each slave controller A maximum of 8 slave controllers can be connected per RS 485 line max line length 200m 2 A power supply can be connected to one or a...

Page 30: ...supply is transmitted from a master or slave controller to subsequent controllers is 200 metres Figure 4 9 Examples of power supply If a GAT NET Controller M 7000 master controller or a GAT SMART Lock...

Page 31: ...S 7000 Figure 4 10 LEDs and buttons provided on the GAT SMART Controller S 7000 LEDs RS 485 IN yellow The connection with the master controller has been established RS 485 IN green RS 485 communicati...

Page 32: ...gh the RS 485 SLAVES socket Figure 4 11 Connection of the GAT SMART Controller S 7000 to the GAT NET Controller M 7000 Observe the following values for the number of connectable controllers per interf...

Page 33: ...try of use see 2 1 System Parts Figure 4 13 Power supply on the GAT NET Controller M 7000 The power supply unit may be placed in the designated storage section inside the master controller 4 4 4 Signa...

Page 34: ...a 16 port GANTNER Art Nr 648182 Sixteen serial ports RJ 45 Please see the manual of the applicable MOXA COM Converter for detailed technical information 4 6 Connection of the GAT SMART LockAxx 6350 Ce...

Page 35: ...485 socket Note Upon delivery the GAT SMART LockAxx Controller Cable No 618027 for connection of the slave control lers is already connected at the GAT SMART LockAxx 6350 The connection to the Etherne...

Page 36: ...GAT SMART Lock 7000 System Electrical Connection 36 HB_GAT SMARTLOCK7000 EN_10 www gantner com...

Page 37: ...contains detailed information about the use and functionality of the software In order to configure a GAT SMART LockAxx 6350 you need to know the main communication settings such as the IP address an...

Page 38: ...After selecting a category the right section 2 dis plays the configuration options of the selected category In order to manage the configuration of one or more central readers in a project follow thes...

Page 39: ...will get its IP set tings from a DHCP server Boolean True Static IP address IP address of the device if DHCP is disabled Integer 192 168 1 37 Static subnet mask Subnet mask of the device if DHCP is di...

Page 40: ...RegExp e g c1 10 c2 11 c3 12 c4 13 c5 14 c6 15 c7 16 c8 17 Application General Sound signals enabled Enable the beeper of the reader Boolean False Time format Format used to show time values on the d...

Page 41: ...l key for division of site keys Hex 00 Enable subsite If enabled the subsite keys of data carriers will be checked Boolean False Same segments struc ture Set to true if all data carriers use the same...

Page 42: ...procedure for configuring the GAT 7000 SMART Lock sys tem For further information about the MOXA COM Converter and its configuration please read the de tailed instructions included with every MOXA CO...

Page 43: ...XA Network configuration example Click on the Serial tab and set these parameters to the serial interface of the MOXA COM Converter at which the slave controllers are connected Enter the values as sho...

Page 44: ...Settings Enter the following values into the Operating Mode window Figure 5 8 COM Converter MOXA Operating mode configuration It is important to ensure that the Operating Mode is set to Real COM Mode...

Page 45: ...OCK7000 EN_10 45 Figure 5 9 COM Converter MOXA Server COM Port Settings Configure the following parameters on the Advanced Settings tab Figure 5 10 COM Converter MOXA Advanced Settings for Server Conn...

Page 46: ...ure 5 11 COM Converter MOXA Serial Settings Confirm the settings with OK Now the GAT SMART Lock 7001 and slave controller system is ready to be managed by a server running cor responding software e g...

Page 47: ...al reader as follows Operation with Central Reader If a central reader is in operation this device serves to identify the user Depending on the design of the central reader user identification can occ...

Page 48: ...The software is only available for 2 weeks if not activated during this time Please contact Gantner Electronic GmbH for licensing and activation codes 6 2 2 User and Role Management GAT Relaxx uses a...

Page 49: ...controllers can be added and the lockers used can be defined per controller 6 Locker overview Here the lockers GAT SMART Lock 7001 of the controller selected on the left are displayed together with t...

Page 50: ...lly displayed The respective locker state is represented by the following colour scheme Unknown State unknown e g no communication with the locker controller Open Locker available unlocked Closed Lock...

Page 51: ...No 043020 0401 Dimensions 84 x 72 x 18 5 mm L x W x H Permitted ambient temperature 30 to 60 C Storage temperature 30 to 70 C Protective type IP 52 Protective class III Weight Approx 0 2 kg Environmen...

Page 52: ...different power cables available Average power consumption 0 5 W Number of GAT SMART Controller S 7000 per RS 485 line Max 8 Communication interface RS 485 Connector types RS 485 to master controller...

Page 53: ......

Page 54: ...dney NSW 2006 Australia T 43 5556 73784 0 T 49 234 58896 0 T 61 2 9011 8114 F 43 5556 73784 8000 F 49 234 58896 11 F 61 2 8209 1708 info gantner com info de gantner com info aus gantner com GANTNER El...

Reviews: