GAT SMART.Lock 7000 System
Configuration
www.gantner.com
HB_GAT-SMARTLOCK7000--EN_10
39
Select the central reader to be configured from the device list on the left. Use the "Add Location" and "Add Device"
buttons to add another central reader to this list. After selecting a central reader the device settings are shown in the
right section. In this section other information such as the configuration history can be viewed and the display texts
of the central reader can be changed.
To open the configuration of a selected central reader, click the button "(2) Configure". The current configuration is
read from the device and the configuration window is displayed which shows the configuration categories and op-
tions (see Figure 5.2).
5.1.2 Configuration Parameters and the Corresponding Default Settings
The following configuration settings are available on the central reader. These settings are edited on the right hand
side of the configuration window in the text and option fields. A description of the settings is provided in the table.
Options
Description
Format
Default Settings
Communication
Ethernet
DHCP enabled
If set to “True”, the device will get its IP set-
tings from a DHCP server.
Boolean
True
Static IP address
IP address of the device (if DHCP is disabled)
Integer
192.168.1.37
Static subnet mask
Subnet mask of the device (if DHCP is disa-
bled)
Integer
255.255.255.0
Static primary DNS
Primary DNS address of the device (if DHCP
is disabled)
Integer
192.168.1.13
Static secondary DNS
Secondary DNS address of the device (if
DHCP is disabled)
Integer
192.168.1.11
Static default gateway
Default gateway of the device (if DHCP is
disabled)
Integer
192.168.1.6
NetBIOS name
NetBIOS name of the device
Text
GA + Part No. +
Serial No.
100 MBit Ethernet
enabled
If set to “True”, 100 MBit Ethernet link is ena-
bled, 10 MBit if disabled
Boolean
True
Hardware
Antenna Selection
Selection of the internal or external antenna
Text
internal
Barcode
Enable
Set to “True” to enable the connected bar-
code scanner
Boolean
True
Display
Contrast
Contrast of the display. Can also be set in the
service menu of the device
Integer
10
SMART.Locks
Number Range Start
First locker number for the locker configura-
tion.
Text
1
Number of locks
Number of connected locks.
Text
1
Master Card action
Defines the action to be performed after iden-
tification with a master data carrier.
Open all ... All connected lockers are opened
Open one ... The individual locker number
that should be opened can be selected
Text
Open One
Summary of Contents for GAT SMART.Lock 7000 System
Page 2: ......
Page 8: ...GAT SMART Lock 7000 System Introduction 8 HB_GAT SMARTLOCK7000 EN_10 www gantner com...
Page 11: ...GAT SMART Lock 7000 System General Information www gantner com HB_GAT SMARTLOCK7000 EN_10 11...
Page 36: ...GAT SMART Lock 7000 System Electrical Connection 36 HB_GAT SMARTLOCK7000 EN_10 www gantner com...
Page 53: ......