SYNCHRONIZING MULTIPLE Q.BRIXX CONTROLLERS
It is possible to synchronize multiple Q.brixx controllers together. In this setup, one
controller is designated the master and the rest are slaves. All controllers use the real
time clock of the master controller. Configuring the software settings for this feature will
be explained in more detail in a section below.
Each Q.brixx test controller (Q.gate and Q.station) has 2 x sync lines. Connect a sync
cable from the master controller to the slave controller (1:1). The sync cable is a 2-wire
twisted pair with LEMO connectors at both ends. The LEMO connector is part #
FGG.00.302.CLAD30Z. The maximum length of all synchronization lines combined can
be 1000 meters.