(10/2000)
20
7 WARNING OUT
The purpose of 7 WARNING OUT is to activate a
warning signal in the event of a malfunction (e.g. a
damaged tape cassette) and prevent recording.
8 TRIGGER OUT
The purpose of control pulse output 8 TRIGGER
OUT is to provide a connection to a corresponding
multiplexer input (CLOCK IN, CONTROL IN or
TRIGGER IN). This clock pulse connection is used
for synchronising the recording status of the VCR
with the video signal transfer function of the
multiplexer. This guarantees - for example - that no
images are lost if there is a brief recording function
start-up delay.
Note
Always use the control pulse output when-
ever possible, as the video recorder timing
signal ensures the smooth synchronisation
of the VCR and multiplexer.
10 LOW TAPE OUT
The function of 10 LOW TAPE OUT is to activate a
warning signal when the tape is running out. The
signal is activated when the tape has about five
minutes left to run.
11 1-SHOT REC IN
The purpose of 11 1-SHOT REC IN is to permit
remote activation of the single-image recording
feature (see pages 14 and 25).
The connections are configured as screw-free plug-
in terminals.
- Strip about 10 mm of insulation from the end of
each connection wire.
- To release the terminal strip locking mechanism,
insert a small screwdriver as far as possible into
the slot beneath the corresponding terminal.
- Insert the bare end of the wire into the terminal
and withdraw the screwdriver.
- Carry out a final check for loose wires.
Installation