Installation and operating instructions 37
11.
Extended operator functions
11.4
Functions overview for the levels
Reference:
If changes are made in Menus 3 and 4 in Level 1, a new learning run must be carried out for the
automatic cut-out. The learning run procedure is described in Section 10.7.
Attention!
To ensure trouble-free programming, the door must be in the CLOSED position before resetting.
Advice:
After a reset, all the parameters revert to the factory settings.
In order to ensure that the controls operate properly:
- all the required functions must be re-programmed,
- the remote control unit must be re-programmed,
- the drive system must be driven once to the OPEN and CLOSED door positions.
Only the intermediate position that was programmed last can be used.
If an automatic closing timer is activated (Level 3 / Menu 1), the relay output (Level 1 / Menu 7)
cannot be programmed.
Level 1 – Basic functions
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
Menu 3:
Intermediate position OPEN
Set using the (+ / OPEN) and (- / CLOSE) buttons
“Intermediate position OPEN” – closing function is possible with automatic closing timer
Menu 4:
Intermediate position CLOSE
Set using the (+ / OPEN) and (- / CLOSE) buttons
Menu 7:
Relay output (only programmable with optimum signal light relay)
A7
B7
C7
D7
E7
F7
G7
H7
I7
J7
K7
–
–
–
–
–
Menu 8:
RESET
No
Yes
–
–
–
–
–
–
–
–
–
–
–
–
–
–