GARANT Safety cable reel
Interval
Maintenance work
Performed by
Immediately
Replace damaged plugs only with plugs
compliant with IEC 60309-1 or IEC
60309-2, with at least 10 A, IP 44.
Trained specialist for electro-technical
work
8.
Faults
Fault
Possible cause
Action
Performed by
Cable not reeling in fully.
Cable jams or catches when
reeling in.
Extend Cable to full length,
allow it to reel in freely.
Trained person
Connected consumer not
starting or switching off.
Cable reel not connected
to mains.
Check fuses.
Plug cable reel into mains.
Trained person
Connected consumer
overloading cable reel.
Heat-sensitive overload
protection has cut power.
1. Unplug cable reel from
mains and unplug all con-
sumers.
»
Cable must be reeled
off to full length.
2.
E
Allow cable reel
to cool for five minutes,
press reset button on
cable reel.
3. Plug cable reel into
mains, connect consumer
to cable drum.
»
Do not exceed the cable
reel’s maximum power
rating.
Trained specialist for electro-
technical work
Overload protection dam-
aged
Replace overload protec-
tion.
Hoffmann Group Customer
Service
9.
Technical data
Designation
Article no. 081198 15
Nominal voltage
250 V
Rated power
fully reeled in: 1600 W at 240 V ~ (7 A)
fully unreeled: 2400 W at 240 V ~ (10 A)
Temperature range
-10 C to + 50 C
Index of protection
IP 44
Usable cable length
15 m
Cable class
H07RN-F
# of cores×cross-section
3×1.5 mm2
Weight Safety cable reel
7.6 kg
Width × depth × height
490 mm × 190 mm × 406 mm
Bracket swing range
180°
10. Cleaning
Disconnect from the power supply before starting cleaning. Clean with a slightly damp cloth. Do not use chemical, alcohol-
based, abrasive or solvent-based cleaners.
11. Transport and storage
Store in the original packaging or box, protected from light, free of dust in a dry place.
12. Spare parts
Order original spare parts from the Hoffmann Group Customer Service.
12