2. To change the dimming direction, briefly lift your finger off the On/Off sensor button.
9.
Faults table
i
The lamp is maintenance-free. The light source can only be replaced by the manufacturer. The mains power adaptor can
only be replaced by the manufacturer.
Fault
Possible cause
Measures
Lamp does not light up.
Mains plug not plugged in.
Insert the mains plug into a mains
socket.
Electronic components defective.
Contact Hoffmann Group customer ser-
vice.
LED defective.
Contact Hoffmann Group customer ser-
vice.
Mains power adaptor defective.
Contact Hoffmann Group customer ser-
vice.
Lamp switches itself off spontaneously. Temperature in the lamp head too high. 1. Do not switch the lamp back on.
»
Allow the temperature in the
lamp head to fall.
2. Switch the lamp back on.
Lamp does not respond to inputs.
Software function is corrupt.
Withdraw the mains plug from the
power supply for a few seconds.
If there is still no response when
switching on again, contact Hoff-
mann Group customer service.
Connection cable damaged.
Mechanical influences on the connec-
tion cable.
Immediately disconnect the dam-
aged connection cable from the
power supply.
Do not reconnect the lamp to the
power supply.
Contact Hoffmann Group customer
service to arrange exchange or re-
pair.
10. Technical data
Dimensions
Designation
Value
Lamp head
Ø 122 mm
Height 13 mm
Lamp support
Length 233 mm + 400 mm + 124 mm
Connecting cable
2300 mm
Magnifying glass data
Lens diameter
Ø 72 mm
Lens power
6 dioptres
Lens material
Hard-coated plastic
LED data
Colour temperature
4000 K
Colour reproduction CRI
Ra > 90; R9 > 50
Colour tolerance, LED
< 3SDCM
Electrical values
Voltage range
100 – 240 V AC
Frequency range
50/60 Hz
Power consumption
6 W