Description
16
Torque
Garant/30
Garant/120
Garant/200
Garant/400
Measuring range
[N m]
[in.lb]
[ft.lb]
3–30
2.3–23
27–270
12–120
9–90
110–1100
20–200
15–150
180–1800
40–400
30–300
360–3600
Display accuracy
±2 % ±1 digit
Display resolution
[N m]
< 10 N m: 0.01 N m
≥ 10
N m: 0.1 N m
Setting resolution
[N m]
0.1
0.2
0.5
1
Overload limit
125 %
Angle
Garant/30
Garant/120
Garant/200
Garant/400
Measuring range
0–999°
Setting range
1–999°
Display accuracy
±2 % ±1 digit
Display resolution
0.1°
Angle setting
resolution
1°
Preload setting
resolution [N m]
0.5
1
1
1
Min. angle rate
≤2.5°/s
Max. angle rate
≥ 45°/s
Description
17
Tolerances
Adjustable:
No tolerance
Relative tolerance
Absolute tolerance
Lower tolerance limit
50–100 % of the nominal value, but at least 80 % of the initial value of
the measuring range
Upper tolerance limit
100–150 % of the nominal value, but max. 120 % of the measuring range
end value
Function modes
Peak (P)
Track (T)
Vibration
Engageable
Alert
Adjustable: 50–90 % of the set value
Display
OLED display
Interface
Micro USB 2.0, Hit-RAW-Device
Memory
Measured values
Max. 2500
Bolting operations
50
Sequences
50 sequence plans with up to 250 bolting operations each
Environmental conditions
Storage temperature
–20 °C–+80 °C
Operating temperature
0 °C–+50 °C
Reference temperature
+20 °C
Relative humidity
20–75 %, non-condensing
Protection class
IP20
Voltage supply
Battery type
Supplied with three micro batteries AA/LR6, 1.5 V
Operating time
12 hours in memory mode with a vibration rate of 15 seconds
DE
FR
IT
ES
www.hoffmann-group.com
17
16
DE
EN
FR
IT
ES
DE
EN
FR
IT
ES