en
GARANT Pressure sprayer
1. Device overview
A
1
Pump button
2
Spray nozzle
3
Safety valve
4
Liquid container
5
Application button
2. General instructions
Read the instructions for use, follow them and keep them available for later reference.
3. Safety
3.1. ESSENTIAL SAFETY INSTRUCTIONS
Pressure sprayer
Risk of injury due to a damaged or pressurised pressure sprayer.
» Do not expose the pressure sprayer to direct sunlight, naked
flames, intense heat or frost.
» Do not leave the pressure sprayer unattended. Protect the pres-
sure sprayer against impacts.
» Before unscrewing the spray head, use the safety valve to fully re-
lease the pressure.
3.2. USE FOR THE INTENDED PURPOSE
Pressure sprayer for indoor use for application of liquids.
For both industrial and private use.
Size VL1 for application of alkali liquids and alcohols.
Size VA1 for application of liquids containing acids.
Size VS1 for application of liquids containing solvents, hydrocarbons (brake cleaners), mineral
oils and greases.
3.2.1. Resistance of the pressure sprayer to materials
Size
VL1
VA1
VS1
Acids
Acetic acid (max. 20%)
x
(x)
-
Hydrochloric acid (max. 30%)
(x)
x
-
Hydrofluoric acid (max. 20%)
-
x
-
Phosphoric acid
(x)
x
-
Nitric acid (max. 20%)
(x)
x
-
Sulphuric acid (max. 30%)
(x)
x
-
Citric acid
x
x
-
Aqua regia
(x)
x
-
Aliphatic hydrocarbons Decane
-
(x)
x
Heptane
-
(x)
x
Hexane
-
(x)
x
Pentane
-
-
x
Aromatic hydrocarbons Limonene
-
(x)
x
Naphthalene
-
x
x
Toluene (max. 40%)
-
(x)
x
Instructions for use
10