se
Ensure the area is kept clean
•
Have lots of rags ready to catch oil spillage.
•
Gain access to the pump assembly and turn off the lift.
•
Install shoring pin
•
Remove emergency lowering connection at the valve
Remove bracket for emergency lowering connection
•
Use a 16mm wrench to remove the nut holding the valve cover in place and
remove the valve cover (black plastic)
Use a 22mm deep socket or a 22mm open-end wrench to undo and remove the
valve body nut. Remove the valve.
•
Insert magnet into tank, install the new valve and complete using the rever
procedure.
ITEM #05751 Revision B
Garaventa Lift, April 2008
20