RC1xx LED Lighting Controllers - User Manual
—
33
—
A typical reply to this command might be:
CH1,MD0,S50.0,0.0,DL1.000ms,PU1.000ms,RT
0.0us,IP1,FL0,CS0.000A,RA0.000A
Where:
CH
Channel number; this is always 1.
MD
Mode: 0 = continuous, 1 = pulsed, 2 = switched.
S
Percentage brightness: 50.0 = 50%; the second part is
always 0.0.
DL
Pulse delay.
PU
Pulse width.
RT
Re-trigger delay.
IP
Always return IP1.
FL
Flags set using the
RE1
command.
CS
Current rating of the light after being sensed
successfully by SafeSense.
RA
Configured voltage or current rating of the light set by
the
VL
command.
Clear configuration
CL
This command clears the configuration and lighting ratings, and turns
the output off. The results of any
VL
,
RU
,
RP
,
RS
,
RW
,
RT
,
RE
,
TT
, and
AW
commands are cleared.
Simulate an input trigger
TR1
This command simulates an input trigger. If the RC120 is in pulse
mode, it pulses the output once.
Enable Ethernet messages
This command enables or disables Ethernet messages. Type in:
GTm
Where:
m
= 0 to disable Ethernet messages, and
m
= 1 to enable Ethernet messages.