RTxxx LED lighting controllers - User Manual
For example:
TT1,200
Set the internal trigger to 200ms (5Hz)
TT1,500US
Set the internal trigger to 500µs (2KHz)
Save the settings to memory
AW
Once the settings are saved to memory they are retained when
the unit is switched off. If this is not done, changes to the
settings are volatile, and if the unit is switched off they revert to
those in force when the last
AW
command was issued.
Clear Configuration
CL
Clears the channel configuration and lighting ratings and sets all
channels to 50% continuous operation. The results of the
VL
,
RS
,
RW
,
RU
,
RT
,
RE
,
RP
,
TT
, and
AW
commands are all cleared.
Show Configuration
ST
This command shows the operational parameters for all
channels in the controller. A typical output for an RT220
controller is:
CH1,MD0,S50.0,0.0,DL1.000ms,PU1.000ms,RT0.0us,IP1,FL0,CS0.
000A,RA0.000A
CH2,MD0,S50.0,0.0,DL1.000ms,PU1.000ms,RT0.0us,IP2,FL0,CS0.
000A,RA0.000
Where:
CH
Channel number
MD
Mode: 0 = continuous, 1 = pulse, 2 = switched, 3 =
select
S
Brightness percentage settings:
1st setting used in all modes
2nd setting only used for select mode
DL
Pulse delay
PU
Pulse width
RT
Retrigger delay
—
58
—