TR-RT LED lighting controllers - User Manual
Clear Configuration
CL
Clears the channel configuration and lighting ratings and sets all
channels to 50% continuous operation. The results of the
VL
,
RS
,
RW
,
RU
,
RT
,
RE
,
RP
,
TT
, and
AW
commands are all cleared.
Show Configuration
ST
This command shows the operational parameters for all channels in
the controller. A typical output for a TR-RT220 controller is:
CH1,MD0,S 50.0,
0.0,DL1.000ms,PU1.000ms,RT
0.0us,IP1,FL0,CS0.000A,RA0.000A
CH2,MD0,S 50.0,
0.0,DL1.000ms,PU1.000ms,RT
0.0us,IP2,FL0,CS0.000A,RA0.000A
Where:
CH
Channel number
MD
Mode: 0 = continuous, 1 = pulse, 2 = switched, 3 =
select
S
Brightness percentage settings:
1st setting used in all modes
2nd setting only used for select mode
DL
Pulse delay
PU
Pulse width
RT
Retrigger delay
IP
Input trigger (set using the
RP
command)
FL
Flags (set using the
RE
command)
CS
Rating of the light (after SafeSense has successfully
completed sensing the light)
RA
Rating of the light (set using the
VL
command).
When using Ethernet, use the following forms of the
ST
command:
ST0
Reports the general settings. A typical output is:
TM 1, TP 20.00ms
—
34
—