USE AND MAINTENANCE MANUAL
GARDASOLAR GOGO4-GOGO6 GS4001-rev6
53 / 69
11.3
State of charge when boat is stationary
The check on the state of charge when stationary is done by measuring the voltage (Volt) when the battery is not in use and
has not been used for at least 4 hours. If the battery is below 75% of its charge, proceed with charging.
BATTERY STATE
OF CHARGE
GEL
BATTERY
AGM
BATTERY
100%
25,7 V or
more
25,6 V or
more
75%
25,3 V
25,2 V
50%
24,7 V
24,6 V
25%
24,0 V
24,0 V
0%
23,6 V
23,6 V
11.4
State of charge while in use
The check on the state of charge during use is done by measuring the voltage (Volt) subjected to a constant current
discharge. For 24V system the battery voltage should be 2 times as in chart.
Values shown are for indication only and refer to Lead Acid Gel technology.
11.5
Charge
SYSTEM
VOLTAGE
[V]
MAX CHARGE VOLTAGE [V]
FLOATING VOLTAGE [V]
12
14.4
13.7
24
28.8
27.5
48
57.6
55.0
Values shown are for indication only and refer to a temperature of 25°C.