17
Appendix 1
:
Installation of Heating Element(Optional)
Warning : The heating element of dehumidifier must be installed by qualified
electrician.
A. Component List :
1)
Heating Element 1 pc
2)
Screws 4 pcs
B. Steps
1
、
Make sure power supply is cut off before working on the unit. Dismantle the
front panel from the unit.
2
、
Place the heating element as shown below:
Signal wire
L(red)
N ( blue)
E (yellow)
Location of heating
A hole for the cord to go
Fasten it wit
h
4 screws