Wintering / Storage : 

Important : 

Disposal : 

(in accordance with 
Directive 2012 / 19 / EU) 

6. Putting Out of Operation 

The watering controller is frost-proof. No measures are required
when frost commences. Legibility of the display is restricted
below 0 °C. 

v

 Check battery status display before the power supply unit is 

disconnected. 

Only dispose of batteries when they are flat.

v

 Return flat batteries to the place you bought them

or

dispose 

of them properly at your local recycling / disposal centre. 

The product must not be added to normal household waste. It
must be disposed of in line with local environmental regulations. 

v

  

Important : Make sure that the unit is disposed of via your 

     municipal recycling collection centre. 

7. Trouble-Shooting 

Fault                                                Possible Cause                             Remedy 

No display                                      

External temperature below          

v

 Wait until the external air

                                                        0 °C or above + 60 °C.                         temperature returns to the

                                                                                                                    operating temperature range. 

AC OFF 

                                           The power supply unit is not          

v

 Plug the power supply unit 

is indicated on the display           

plugged in.                                           into a mains socket. 

(the programs are retained)

Overload 

                                      The power supply is over-              

v

 Only so many valves may be 

is indicated on the display 

         loaded because valves from               opened at the same time that 

(the programs are retained).            other manufacturers have                    the total power consumption 

                                                        been used.                                           does not exceed 800 mA. 

                                                        Cabling of the valves has a            

v

 Cable the valves properly 

                                                        short circuit.                                         (see 4. Initial Operation 

                                                                                                                       

“Connecting the valves” ). 

The Watering Controller is reset to the default setting and
all the program data is deleted. 

1.

 

Press and hold down the 

OK

key. 

2.  Also press and hold down the 

Channel

key for 3 seconds. 

    

The lock symbol is displayed. 

  All the symbols of the display light up for 2 seconds. 

  The program data for 

all

programs is deleted. 

  The date and time are retained. 

  The key lock is cancelled. 

A reset can be triggered at any time. 

Tip : 

Should you have any questions about operating and 

programming your Watering Controller, please do not hesitate 
to contact your nearest GARDENA Service Centre. 

Reset function : 

Summary of Contents for 4030

Page 1: ...F Mode d emploi Programmateur NL Gebruiksaanwijzing Besproeiingscomputer S Bruksanvisning Kontrollpanel DK Brugsanvisning Vandingskontrol system FIN Brugsanvisning Kastelunohjauslaite N Brugsanvisning...

Page 2: ...Please keep these instructions in a safe place 1 Where to Use your GARDENA Watering Controller 15 2 Safety Instructions 16 3 Function 16 4 Initial Operation 17 5 Operation 19 6 Putting Out of Operatio...

Page 3: ...the battery is almost empty and has to be replaced When the Low Battery display appears the battery is empty or no battery has been inserted The Low Battery display is re set once the new battery has...

Page 4: ...24 V AC terminals only Before programming your Watering Controller install a 9 V battery to prevent loss of data if a power failure occurs 1 Release snap lock 1 and open cover 2 2 Connect the cable of...

Page 5: ...le terminals C are interconnected and equivalent to one another 4 Connect one cable of the valve V2 to the cable terminal 2 of the valve box 5 Connect the other cable of the valve V2 to a cable termin...

Page 6: ...e week is selected automatically using the date When the Time key is pressed all the valves are clo sed as a precaution 1 Plug in the power supply unit or press the Time key YEAR and date year flash i...

Page 7: ...annel key SELECT CHANNEL and the channel flash You can end the programming mode at any time by pressing the Channel key 2 Select the channel using the keys e g channel 2 and confirm by pressing the OK...

Page 8: ...OK key The selected watering days e g Mo We Fr are shown on the display in frames 9 Press the Channel key and set up more watering programs The program is saved and SELECT CHANNEL and the channel fla...

Page 9: ...nel e g channel 2 is shown in the display If several channels are blocked Channels off is displayed If the run time is not equal to 100 the display alternates every 3 seconds between Channel off and R...

Page 10: ...confirmed within 10 seconds by pressing the OK key the watering begins with the watering duration displayed You can exit watering all the channels prematurely by pressing the OK key Man key for 3 seco...

Page 11: ...ak 1 to 9 or they can all be blocked Off in which case manual watering is still possible 1 Press the Rain Off key Rain Off and Off is displayed 2 Using the keys set the desired break e g 3 days 3 Day...

Page 12: ...FF The power supply unit is not v Plug the power supply unit is indicated on the display plugged in into a mains socket the programs are retained Overload The power supply is over v Only so many valve...

Page 13: ...n of the problem directly to one of the GARDENA Service Centres listed on the back of this leaflet A In the event of other faults please contact GARDENA Service Repairs should only be carried out by G...

Page 14: ...e Th Fr Sa Su 1 2 3 Channel Prog START TIME RUN TIME 24 h 2nd 3rd Odd Even Mo Tu We Th Fr Sa Su 1 2 3 Channel Prog START TIME RUN TIME 24 h 2nd 3rd Odd Even Mo Tu We Th Fr Sa Su 1 2 3 Channel Prog STA...

Page 15: ...oduktansvar Vi g r udtrykkeligt opm rksom p at i henhold til produktansvarsloven er vi ikke ansvarlige for skader for rsaget af vores udstyr hvis det skyldes uautoriserede reparationer eller hvis dele...

Page 16: ...onformit alle norme UE La sottoscritta Husqvarna AB 561 82 Huskvarna Sweden certifica che il prodotto qui di seguito indicato nei modelli da noi commercializzati conforme alle direttive armonizzate UE...

Page 17: ...td Preston Road Aycliffe Industrial Park Newton Aycliffe County Durham DL5 6UP info gardena husqvarna co uk Italy Husqvarna Italia S p A Via Como 72 23868 VALMADRERA LC Phone 39 0341 203 111 info gard...

Reviews: