background image

13

GB

12

GB

6. Trouble-shooting 

Warning ! Electric shock ! 

V   

Disconnect the pump from the mains before 
working on it.

1. Remove pump from the filter housing (see 5. Maintenance).

2. FP 750 E : Detach the cap 

G

from the motor housing 

F

at the

catches 

H

.

Other pumps : Turn the pump housing 

E

anticlockwise and

pull it vertically off the motor housing 

F

.

3. Pull impeller unit 

I

out of the motor housing 

F

and clean.

4. Push cleaned impeller unit 

I

back into the motor housing 

F

.

5. FP 750 E : Push pump cap 

G

onto motor housing 

F

.

Other pumps: Press pump housing 

E

vertically onto motor

housing 

F

and turn clockwise.

FP 4000 E / FP 5000 E / FP 7500 E: During assembly, ensure
that the seal / foam filter 

J

is correctly seated in the motor hous-

ing 

F

.

Fault Possible 

cause 

Remedy 

No water feature operating.

Mains plug not plugged in.

V

Plug in mains plug.

Impeller unit is blocked.

V

Clean pump.

Regulating valve at pump or 

V

Open the appropriate 

pond edge controller is closed.

regulating valve.

FP 1800 E / FP 2500 E /

Thermal overload switch has 

1. Unplug the mains plug

FP 7500 E

been triggered 

and allow the pump to cool

(pump has run dry).

2. Plug the mains plug back 

in after approx. 2 minutes.

FP 750 E FP 1000 /

Electronic dry-running safety 

V

Unplug the mains plug, 

FP 1400 E / FP 4000 E /

has been triggered.

stand the pump in the 

FP 5000 E / FP 7500 E

water and plug the 
mains plug back in.

Water feature reduced in 

Water feature insert is dirty.

v

Clean water feature 

size and uneven

insert and nozzle pipe.

Air lock in the hose.

v

Fill connection hose for
pond edge filter/pump with 
water.
(see 4. Initial Operation).

Filter housing / pond 

v

Clean filter housing / -

edge filter dirty.

pond edge filter.

If any other faults arise, please contact GARDENA Service.

Clean filter housing :

Clean the filter of the pond
edge controller:

Clean water feature insert
and nozzle pipe :

Clean the pump :

Additional consumers (e.g. gargoyles) can be connected to the
side outlet 

B

(1/2

, 3/4

and 1

”nipple)

The quantity of water can 

be adjusted via the regulator

C

.

Note: The ball joint 

D

can be used to align the water feature so

that it is vertical.

5. Maintenance 

Warning ! Electric shock ! 

Disconnect the pump from the mains before working on it.

Do not use any hard objects or powerful detergents for cleaning
the set! 

1. Unscrew nozzle pipe.

2. Unscrew water feature insert and remove from nozzle pipe.

3. Clean nozzle pipe and water feature insert in clean water.

1. Take water feature pump out of the water.

2. Unlock snap fastenings 

6

and open up the filter housing 

5

.

3. Clean filter housing 

5

with a jet of water.

4. Hook the halves of the filter housing into each other and close.

Do not use any hard objects or powerful detergents for cleaning
the set! 

Light soiling :

v

Clean the filter surface of the pond edge controller under
water
.

Heavy soiling :

1. Disconnect the pond edge controller from the hose underwater

to prevent air from being drawn in.

2. Take pond edge controller out of the water, open and clean.

3. Reconnect the pond edge controller to the hose under water.

Side outlet :

B

C

D

7

5

6

E

G

I

J

H

F

 

 

 

Summary of Contents for FP 750 E

Page 1: ...ng Wasserspielpumpen Set GB Operating Instructions Fountain Pump Set F Mode d emploi Pompe pour jets d eau NL Gebruiksaanwijzing Waterspelpomp set S Bruksanvisning Fontän Pump Set I Istruzioni per l uso Pompa per giochi d acqua E Manual de instrucciones Bomba para juegos de agua P Instruções de manejo Bomba para fontes DK Brugsanvisning Springvandspumpesæt D GB F NL S I E P DK ...

Page 2: ...re not designed for operating watering tools and systems The pumps may be used indoors as well as outdoors GARDENA Fountain Pumps have not been designed for con stant use in the industrial sector Corrosive easily combustible aggressive or explosive substances e g petrol petroleum nitro thinner as well as salt water or food drinking water must not be pumped Intended Use Please note 2 For Your Safet...

Page 3: ...dges The temperature of the liquid used must not be below 4 C or above 35 C Sand and other abrasive substances in the liquid cause increased wear and reduce the output of the pump Please observe the local noise prevention regulations All pumps a cascade art 7650 b Waterbell 7654 c jets of water art 7655 7657 d foaming spring 3 Assembly To provide a firmer mounting the filter housing can be attache...

Page 4: ... Operation 1 Place water feature pump on a firm base in such a way that the filter housing 5 is completely covered by water 2 Pull telescopic pipe 9 out to the desired length 3 Netzstecker in eine Wechselstromsteckdose einstecken Warning Pump will start immediately 4 Set the quantity of water required for the water feature using the regulator 0 5 Water bell Screw insert into the water feature unti...

Page 5: ...2 Unscrew water feature insert and remove from nozzle pipe 3 Clean nozzle pipe and water feature insert in clean water 1 Take water feature pump out of the water 2 Unlock snap fastenings 6 and open up the filter housing 5 3 Clean filter housing 5 with a jet of water 4 Hook the halves of the filter housing into each other and close Do not use any hard objects or powerful detergents for cleaning the...

Page 6: ...rating Mains plug not plugged in V Plug in mains plug Impeller unit is blocked V Clean pump Regulating valve at pump or V Open the appropriate pond edge controller is closed regulating valve FP 1800 E FP 2500 E Thermal overload switch has 1 Unplug the mains plug FP 7500 E been triggered and allow the pump to cool pump has run dry 2 Plug the mains plug back in after approx 2 minutes FP 750 E FP 100...

Page 7: ... room GARDENA Spiral Pond Hoses For connecting the pond edge controller art 7896 art 7898 GARDENA Water Features For designing your own pond and art 7814 art 7823 water features GARDENA Telescopic Tubes For extending the nozzle tube art 7884 art 7885 9 Technical Data Type FP 750E FP 1000E FP 1400E FP 1800E FP 2500E FP 4000E FP 5000E FP 7500E Art No 7650 7651 7652 7653 7654 7655 7656 7657 Rated pow...

Page 8: ...s of the operating in structions Neither the purchaser or a non authorised third party have attempted to repair the unit The feed impeller is a wearing part and is not covered by the warranty This manufacturer s guarantee does not affect the user s existing warranty claims against the dealer seller If you have any problems with your Fountain Pump Set please contact our Service or return the defect...

Reviews: