Guarantee 

10. Service 

GARDENA guarantees this product for 3 years (from date of 
purchase). This guarantee covers all serious defects of the unit
that can be proved to be material or manufacturing faults. Under
warranty we will either replace the unit or repair it free of charge 
if the following conditions apply:

The unit must have been handled properly and in keeping 
with the requirements of the operating in-structions.

Neither the purchaser or a non-authorised third party have
attempted to repair the unit.

The feed impeller is a wearing part and is not covered by the 
warranty.

This manufacturer’s guarantee does not affect the user’s existing
warranty claims against the dealer / seller.

If you have any problems with your Fountain Pump Set, please
contact our Service or return the defective unit together with a
short description of the problem – in case of guarantee, with a
copy of the receipt – postage paid to one of the GARDENA
Service Centres listed on the back of this leaflet.

7. Storing your Fountain Pump Set

The pump should be stored out of the reach of children.

1. Remove the pump from the pond before frost is expected and

clean.

2. To avoid difficulties when starting up in the spring, we recom-

mend storing the pump in a frost-free location in a container 
filled with water.
The mains plug must not be submerged.

8. Accessories 

GARDENA Underwater lights 

Illuminate water features and the edges of the

art. 7951

pond from below the surface of the water.

GARDENA radio control set  

Start water features and lighting from 

art. 7874

the terrace or your living room.

GARDENA Spiral Pond Hoses

For connecting the pond edge controller.

art. 7896 
art. 7898

GARDENA Water Features

For designing your own pond and                   art. 7814 - art. 7823
water features.

GARDENA Telescopic Tubes

For extending the nozzle tube.

art. 7884 - art. 7885

9. Technical Data 

Type

FP 750 E FP 1000 E FP 1400 E FP 1800 E FP 2500 E FP 4000 E FP 5000 E FP 7500 E

Art.-No.

7650

7651

7652

7653

7654

7655

7656

7657

Rated power 

8 W 

15 W

18 W

25 W

30 W 

60 W

80 W

120 W

Flow 

750 l / h 1000 l / h 1400 l / h 1800 l / h 2300 l / h

4200 l / h 4800 l / h 7500 l / h

Max. delivery head 

1,3 m

1,8 m

2,0 m

2,2 m

2,4 m

3,2 m

3,9 m

4,5 m

Max. submersion depth 

4 m

4 m

Power cable 

10 m H05 RN-F3G0,75

10 m H05 RN-F3G1,0

Fitting 

G 3 /4

G 1 

Media temperature 

4 °C – 35 °C

4 °C – 35 °C

Mains voltage / Frequency

230 V / 50 Hz

230 V / 50 Hz

Overwintering :

 

 

 

Summary of Contents for FP 750 E

Page 1: ...ng Wasserspielpumpen Set GB Operating Instructions Fountain Pump Set F Mode d emploi Pompe pour jets d eau NL Gebruiksaanwijzing Waterspelpomp set S Bruksanvisning Fontän Pump Set I Istruzioni per l uso Pompa per giochi d acqua E Manual de instrucciones Bomba para juegos de agua P Instruções de manejo Bomba para fontes DK Brugsanvisning Springvandspumpesæt D GB F NL S I E P DK ...

Page 2: ...re not designed for operating watering tools and systems The pumps may be used indoors as well as outdoors GARDENA Fountain Pumps have not been designed for con stant use in the industrial sector Corrosive easily combustible aggressive or explosive substances e g petrol petroleum nitro thinner as well as salt water or food drinking water must not be pumped Intended Use Please note 2 For Your Safet...

Page 3: ...dges The temperature of the liquid used must not be below 4 C or above 35 C Sand and other abrasive substances in the liquid cause increased wear and reduce the output of the pump Please observe the local noise prevention regulations All pumps a cascade art 7650 b Waterbell 7654 c jets of water art 7655 7657 d foaming spring 3 Assembly To provide a firmer mounting the filter housing can be attache...

Page 4: ... Operation 1 Place water feature pump on a firm base in such a way that the filter housing 5 is completely covered by water 2 Pull telescopic pipe 9 out to the desired length 3 Netzstecker in eine Wechselstromsteckdose einstecken Warning Pump will start immediately 4 Set the quantity of water required for the water feature using the regulator 0 5 Water bell Screw insert into the water feature unti...

Page 5: ...2 Unscrew water feature insert and remove from nozzle pipe 3 Clean nozzle pipe and water feature insert in clean water 1 Take water feature pump out of the water 2 Unlock snap fastenings 6 and open up the filter housing 5 3 Clean filter housing 5 with a jet of water 4 Hook the halves of the filter housing into each other and close Do not use any hard objects or powerful detergents for cleaning the...

Page 6: ...rating Mains plug not plugged in V Plug in mains plug Impeller unit is blocked V Clean pump Regulating valve at pump or V Open the appropriate pond edge controller is closed regulating valve FP 1800 E FP 2500 E Thermal overload switch has 1 Unplug the mains plug FP 7500 E been triggered and allow the pump to cool pump has run dry 2 Plug the mains plug back in after approx 2 minutes FP 750 E FP 100...

Page 7: ... room GARDENA Spiral Pond Hoses For connecting the pond edge controller art 7896 art 7898 GARDENA Water Features For designing your own pond and art 7814 art 7823 water features GARDENA Telescopic Tubes For extending the nozzle tube art 7884 art 7885 9 Technical Data Type FP 750E FP 1000E FP 1400E FP 1800E FP 2500E FP 4000E FP 5000E FP 7500E Art No 7650 7651 7652 7653 7654 7655 7656 7657 Rated pow...

Page 8: ...s of the operating in structions Neither the purchaser or a non authorised third party have attempted to repair the unit The feed impeller is a wearing part and is not covered by the warranty This manufacturer s guarantee does not affect the user s existing warranty claims against the dealer seller If you have any problems with your Fountain Pump Set please contact our Service or return the defect...