background image

Active (manual) watering 

v

 (Fig. I): 

1 Manual watering

Setting schedules 

v

 (Fig. H):  

Set schedule | 2 Schedule 1 

Configure and save up to 6 different watering 

schedules by setting the start time, duration and 

weekdays for each one. Schedules can be acti-

vated or deactivated by pressing on / off (see fig. H).

Default display 

v

 (Fig. J):

1 Idle screen | 2 Programs

Seasonal watering duration 

(Fig. K):   

1 Menu: Seasonal Run Time | 2 Regular Run Time |  

3 Reduce Watering

You can reduce the durations set for all schedules 

at once in 10% increments, from 100% down  

to 10%. This saves you having to change each  

of the 6 schedules individually. 

Tip: Less watering is required in the spring and 

autumn than in the height of summer. Simply set 

the maximum watering duration for high summer  

as the default. Then reduce the watering duration 

for all schedules at once in convenient 10 % incre-

ments when there is less need for watering.  

Note: When you change the percentage, the dura-

tion is adjusted within the schedules and the 

“cloud” symbol appears. If the duration is not 

altered (= 100 %), the “sun” symbol is displayed.

Rain pause  

v

 (Fig. L):

1 Menu: Rain pause | 2 Pause / 3 days 

Pauses all watering operations without changing 

the set schedules. You can select any number of 

days between 1 and 9. At the end of the pause,  

all schedules are reactivated.

Deleting a schedule 

v

 (Fig. M):

1 Menu: Delete schedule | 2 Delete schedule 1

Soil Moisture Sensor, Art. 1188 

(optionally available) 

v

 (Fig. D and N):  

1 Menu: Soil Moisture  Sensor 

Once the soil is sufficiently moist, a water-

ing operation is interrupted or a schedule is disa-

bled so that it cannot be activated. This does not 

affect active (manual) watering.

v

 (Fig. D and N): 

1 Connect soil moisture sensor

After a soil moisture sensor is connected, the 

 “sensor activated / deactivated” display will appear – 

this can take up to 1 minute. Select an option to 

activate/deactivate the sensor response. Use the 

switching point controller on the soil moisture sen-

sor to set the level of soil moisture that must be 

achieved before the sensor responds (see Opera-

tor’s Manual for GARDENA Soil moisture sensor).

Seasonal Run Time 

 Adjustment

EN

9

Summary of Contents for Master

Page 1: ...Brugsvejledning Vandingskontrol FI K ytt ohje Kastelunohjaus NO Bruksanvisning Vanningsstyring ET Kasutusjuhend Kastmiss steemi juhtseade LT Eksploatavimo instrukcija Laistymo valdiklis LV Lieto anas...

Page 2: ...7 days dry We Sensor SCHEDULE 1 MENU Active Watering M T T F S S W P1 ON Schedule 1 P1 P6 Sensor Schedule on off I 1 Manual watering G 1 Set language 2 Set weekday 3 Set time hrs min 4 Ready for sched...

Page 3: ...hedule 1 Schedule 2 Schedule 3 Time 08 30 Day Wed TIME DAY 1 Menu Water Distributor automatic Sensor settings Water Distributor automatic Delete schedule We Water Distributor automatic Delete schedule...

Page 4: ...ed ill or under the influence of alcohol drugs or medicine Intended use The GARDENA Water Control is intended for private use in domestic and hobby gardens exclusively for outdoor use to control sprin...

Page 5: ...wn the LCD display illuminates again The max temperature for the water flow is 40 C Avoid tensile strain v Do not pull the hose connected to the Water Control CAUTION If the control section is removed...

Page 6: ...ly available Each line can be activated up to once a day You can change the settings or move to the next setting by turning the knob You can confirm the respective input by pressing the rotary knob Pr...

Page 7: ...tion is adjusted within the schedules and the cloud symbol appears If the duration is not altered 100 the sun symbol is displayed Rain pause v Fig L 1 Menu Rain pause 2 Pause 3 days Pauses all wateri...

Page 8: ...watering operation will be postponed and a pause of 5 minutes will be inserted between the operations Start times Define the start times for the water lines in chronological order This makes it easier...

Page 9: ...it should be removed fig B v Store the controller and the valve unit in a dry enclosed and frost free place Disposal in accordance with RL2012 19 EC The product must not be disposed of to normal house...

Page 10: ...rt a new alkaline battery Tap is turned off v Turn the tap on Controller is not connected v Mount the controller on housing Minimum pressure of 0 5 bar not available v Ensure a pressure of at least 0...

Page 11: ...Remedy Watering program is not being undertaken no watering Low battery is continuously displayed v Insert a new alkaline battery Minimum pressure of 0 5 bar not available v Ensure a pressure of at le...

Page 12: ...Operating temperature range 5 C to 50 C Flow medium Clear fresh water Max liquid temperature 40 C Number of program controlled watering cyclesper day 6 individual start times Water Control Value Unit...

Page 13: ...open or repair the product Only Original GARDENA replacement parts and wear parts have been used for operation Presentation of the receipt Normal wear and tear of parts and components such as blades...

Page 14: ...n vaurioista jos korjauksia ei ole tehnyt GARDENAn hyv ksym huoltoliike tai jos niiden syyn on muiden kuin alkuper isten GARDENA varaosien tai GARDENAn hyv ksymien varaosien k ytt ET Tootevastutus Vas...

Page 15: ...vakuutus GARDENA Germany AB PO Box 7454 S 103 92 Stockholm Ruotsi vakuuttaa t ten ett alla mainitut laitteet ovat tehtaalta l htiess n yhdenmukaistettujen EU s nn sten EU n turvastan dardien ja tuotek...

Page 16: ...me 20 12 2018 Authorised representative Auktoriserad representant Autoriseret repr sentant Valtuutettu edustaja Volitatud esindaja galiotasis atstovas Pilnvarot persona Reinhard Pompe Vice President H...

Page 17: ...a GmbH Industriezeile 36 4010 Linz Tel 43 732 77 01 01 485 service gardena husqvarnagroup com Cyprus Med Marketing 17 Digeni Akrita Ave P O Box 27017 1641 Nicosia Czech Republic Husqvarna esko s r o T...

Page 18: ...00 39 6 02_04 http www gardena ru Serbia Domel d o o Autoput za Novi Sad bb 11273 Belgrade Phone 381 118488812 miroslav jejina domel rs Singapore Hy Ray PRIVATE LIMITED 40 Jalan Pemimpin 02 08 Tat Ann...

Reviews: