17
16
1. Press
man. On / Off
-key to open the valve manually
(or to close an open valve).
RRUUNN TTIIMMEE
and the watering time in minutes (set to
3300
minutes
in the works) flash for 5 seconds on the display.
2. Whilst the watering time in minutes is flashing, the watering
duration can be modified with the
▲
-key (between
00 ::0000
and
00 ::5599
) (example:
1100
minutes).
The valve is opened.
3. Press
man. On / Off-
key to close the valve early.
The valve is closed.
The amended manual opening period is stored, i.e. each time
the valve is opened manually in future the modified opening
period is preset. If the manual opening period is amended to
00 ::0000
, the valve is closed and also remains closed after the
man. On / Off
-key is pressed (child lock).
If the valve has been opened manually and a programmed start
of a watering period overlaps the manual opening period, the
programmed starting time is suppressed.
Example :
The valve is
opened
at
9.00 a.m. manually,
the
opening period is 30 minutes. A program with a
start time
(START TIME)
between
9.00 and 9.30 a.m.
will not be under-
taken in this case.
1.
2.
GB
GB
Budget-Function (% Run-Time) :
The times of all stored watering programmes can be reduced cen-
trally in intervals of 10 %, from 100 % down to 10 %, without having
to change each interval programme. This is ideal if you wish to
water your garden less in the Autumn than in the Summer.
Note :
If you change the watering time percentage, your Water
Computer will still display the watering time you originally pro-
grammed for the individual watering programs.
If a program has already been set on one of the 6 program
memory settings, this can be modified without having to compile
it from the beginning again.
1. Press
Menu
-key twice.
Program memory setting
1
flashes.
2. Press
O.K.
-key to move to the next program step
– or –
modify program data with the
▲
-key and confirm with the
O.K.
-key.
The valve can be
opened or closed manually at any time.
A program-controlled open valve can also be closed early with-
out changing the program data (start time, watering duration
and watering days).
Read / modify
watering programs :
Manual operation :
Programmed watering time
Watering program deactivated
1100 -- 110000
% Run-Time
= Watering program active
00
Prog. Off
= Watering program inactive