g) Do not use the pole pruner in bad weather conditions, especially
when there is a risk of lightning.
This decreases the risk of being struck by lightning.
Extended-Reach Pole Pruner safety warnings
a) To reduce the risk of electrocution, never use the extended-reach pole
pruner near any electrical power lines. Contact with or use near power
lines may cause serious injury or electric shock resulting in death.
b) Always use two hands when operating the extended-reach pole
pruner.
Hold the extendedreach pole pruner with both hands to avoid loss of control.
c) Always use head protection when operating the extended-reach pole
pruner overhead. Falling debris can result in serious personal injury.
Search hedges and trees for hidden objects (e. g. wire fences and hidden wires).
The use of a residual current device (RCD) with a trip current of 30 mA or less is
recommended.
Hold the pole pruner with both hands on both handles.
The pole pruner is intended for use when the user is standing on the ground and
not on a ladder or other unstable surface.
Before using the pole pruner, make sure that the locking devices of all moving
parts (e. g. the extended shaft and the pivot element) are in the locked position.
Additional safety warnings
DANGER! Small parts can be easily swallowed. There is also a risk that the poly-
bag can suffocate toddlers. Keep toddlers away when you assemble the product.
Work area safety
Only use the unit in the manner and for the functions described in these instruc-
tions.
The operator or user is responsible for accidents or hazards occurring to other
people or their property.
While operation and transport pay special attention to the hazard for third parties
posed by the increased working radius when the telescopic tube is extended.
Risk of stumbling. While operation pay attention to the cable.
Pay special attention in winter when it is slippery.
Warning! When wearing hearing protection, and due to the noise produced by
the unit, the operator may not notice persons approaching.
Do not use the unit when a thunderstorm is approaching.
Do not use the unit nearby a water.
Electrical safety
The British Standards Institute recommend the use of a Residual Current Device
(R.C.D.) with a tripping current of not more than 30 mA. Check your R.C.D. every
time you use it.
Before use, examine cable for damage, replace it if there are signs of damage or
ageing.
If the replacement of the supply cord is necessary, this has to be done by the
manufacturer or his agent in order to avoid a safety hazard.
Do not use the unit if the electric cables are damaged or worn.
Immediately disconnect from the mains electricity supply if the cable is cut, or the
insulation is damaged. Do not touch the electric cable until the electrical supply
has been disconnected.
Your electric cable must be untangled, tangled cables can overheat and reduce
the efficiency of your unit.
Always disconnect the mains cable before disconnecting any plug, cable connec-
tor or extension cable.
Switch off, remove plug from mains and examine electric supply cable for damage
or ageing before winding cable for storage. Do not repair a damaged cable, send
the unit to the next GARDENA Service Center or dealer authorised by GARDENA.
Always wind cable carefully, avoiding kinking.
Use only on AC mains supply voltage shown on the product rating label.
Under no circumstances should an earth be connected to any part of the unit.
If the unit starts unintentionally when the mains plug is connected, disconnect the
mains at once. Contact GARDENA Service to check the unit.
DANGER! This product makes an electromagnetic field while it operates. This
field may under some conditions interfere with active or passive medical implants.
To decrease the risk of conditions that can possibly injure or kill, we recommend
persons with medical implants to speak with their physician and the medical
implant manufacturer before you operate the product.
Cables
Use only permitted extension cables as per HD 516.
v
Ask your electrical specialist.
Personal safety
Always wear suitable clothing, protective gloves, and stout shoes.
Avoid contact to the oil of the chain in particular when you react allergic with it.
Thoroughly inspect the area where the unit is to be used and remove all wires
and other foreign objects.
All adjustments (inclining the motor unit, altering the length of the telescopic tube)
have to be made with the sheath in place, and the unit must not rest on the bar in
the process.
Fig. S1: Always hold the unit properly with both hands on both handles
(20)
and
(25)
.
Before using the machine and after any impact, check for signs of wear or
damage and repair as necessary.
Never attempt to use an incomplete unit or one with an unauthorised modifica-
tion.
Power tool use and care
Know how to stop the unit quickly in an emergency.
Never hold the unit by the guard.
Do not use the unit if the protection equipments (protection cover, quick
blade-stop) are damaged.
Do not use ladders whilst operating the unit.
Disconnect the mains cable:
– before leaving the unit unattended for any period;
– before clearing a blockage;
– before checking, cleaning or working on the appliance;
– if you hit an object. Do not use your unit until you are sure that the entire unit is
in a safe operating condition;
– if the unit starts to vibrate abnormally. Check immediately. Excessive vibration
can cause injury.
– before passing to another person.
Only use the unit between 0 – 40 °C.
Maintenance and storage
RISK OF INJURY!
Do not touch the chain.
v
When finishing or interrupting work push up protection cover.
Keep all nuts, bolts and screws secure to be sure the unit is in safe working
condition.
If the unit got hot during operation, let it cool down before storage.
2. ASSEMBLY
The Pruner, chain, bar, protective cover complete with Allen key and the
operation instructions are included in the scope of delivery.
DANGER! Risk of injury!
Cut injury when the unit starts accidentally.
v
Before you assemble the unit, make sure that the mains cable
is disconnected and the protective cover
1
is slid over the
bar
2
and the snap fit
3
is closed [ Fig. A1 ].
To assemble the telescopic handle [ Fig. A2 / A3 ]:
1. Slide the telescopic pipe
4
into the motor unit
5
until you reach the
stop position. Ensure that the two markings
(M)
face each other.
2. Tighten the grey nut
6
.
To assemble the shoulder strap [ Fig. A4 ]:
CAUTION!
The supplied shoulder strap must be used.
1. Widen the belt clip
7
and fasten it onto the beam using the screw
8
.
2. Engage the shoulder strap clasp
9
to the belt clip
7
.
3. Adjust the shoulder strap to the desired length by using the
quick strap fastener.
3. INSTALLATION
Initial Operation [ Fig. A1 ]:
DANGER! Risk of injury!
Cut injury when the unit starts accidentally.
v
Before you initially operate the unit, make sure that the mains
cable is disconnected and the protective cover
1
is slid over
the bar
2
and the snap fit
3
is closed.
To fill in chain oil [ Fig. I1 ]:
DANGER! Risk of injury!
Physical injury due to chain breakage when the chain on
the bar is not sufficiently lubricated.
v
Check whether sufficient quantities of chain oil are delivered
prior to each use.
We recommend to use Art. 6006 GARDENA Oil or an equivalent mineral