8. Technical data 

UL 20 (Art. 7952)

UL 35 (Art. 7954)

UL 20 S Set (Art. 7958)

Transformer :
Mains voltage / mains frequency

230 V AC / 50 Hz 

230 V AC / 50 Hz 

230 V AC / 50 Hz 

Nominal output 

21VA

36 VA 60 VA 

Output voltage

12 V AC 12 V AC 12 V AC 

Number of outputs 

1 1 3 

Mains cable 

2 m  H05-RN-F 

2 m  H05-RN-F 

2 m  H05-RN-F 

Underwater Light :
Halogen lamp (base GU5.3) 

20 W /10° / 12 V

35 W /10° / 12 V

3  x  20 W /10° / 12 V

Connecting cable length 

5 m  H03-VV-F 

5 m  H03-VV-F 

3 x 5 m  H03-VV-F 

Ambient temperature 

0 °C - 40 °C 

0 °C - 40 °C 

0 °C - 40 °C 

9. Service / Warranty 

GARDENA guarantees this product for 2 years (starting from 
date of purchase). This guarantee covers all serious defects of 
the unit that can be proved to be material or manufacturing faults.
Under warranty we will either replace the unit or repair it free of
charge if the following conditions apply:

The unit must have been handled properly and in keeping 
with the requirements of the operating instructions.

Neither the purchaser or a non-authorised third party have
attempted to repair the unit.

The bulb is classed as a consumable item and is excluded from
the warranty.

This manufacturer’s guarantee does not affect the user’s existing
warranty claims against the dealer / seller.

If a fault occurs with your Underwater Light, please return the
faulty unit together with a copy of the receipt and a description
of the fault, with postage paid to one of the GARDENA Service
Centres listed on the back of these operating instructions.

Summary of Contents for UL 20

Page 1: ...immersible NL Gebruiksaanwijzing Onderwaterspot S Bruksanvisning Undervattenslampor I Istruzioni per l uso Faretto subacqueo E Manual de instrucciones Foco subacu tico P Instru es de utiliza o Holofo...

Page 2: ...ion 9 4 Storage 11 5 Cleaning 11 6 Troubleshooting 11 7 Accessories 12 8 Technical data 12 9 Service Warranty 12 1 Where to Use Your GARDENA Underwater Light GARDENA Underwater Lights operate on a 12...

Page 3: ...nected in parallel Do not expose the transformer to direct sunlight The transformer must be operated via a fault current circuitbreaker FI switch with a nominal fault current 30 mA DIN VDE 0100 702 v...

Page 4: ...mounting 8 and tighten the adjuster 7 2 Adjusting the horizontal beam angle Turn the light to the desired horizontal beam angle 3 Adjusting the vertical beam angle Slacken the adjuster 7 by screwing...

Page 5: ...he transformer at the mains Use only 12 V halogen bulbs base GU5 3 of the same power UL 20 20 W 10 UL 35 35 W 10 UL 20 S Set 3 x 20 W 10 Spare bulbs can be obtained as required from GARDENA Service 1...

Page 6: ...rs starting from date of purchase This guarantee covers all serious defects of the unit that can be proved to be material or manufacturing faults Under warranty we will either replace the unit or repa...

Page 7: ...om skadan beror p att produkten har reparerats felaktigt eller om vid repa ration eller utbyte andra n Original GARDENA reservdelar har anv nts Samma sak g ller f r kompletteringsdelar och tillbeh r...

Page 8: ...europ ennes nonc es ci apr s et conforme aux r gles de s curit et autres r gles qui lui sont applicables dans le cadre de l Union europ enne Toute modification port e sur ce produit sans l accord exp...

Page 9: ...Tunguhalsi 1 110 Reykjavik ooj ojk is Ireland Michael McLoughlin Sons Hardware Limited Long Mile Road Dublin 12 Italy GARDENA Italia S p A Via Donizetti 22 20020 Lainate Mi Phone 39 02 93 94 79 1 info...

Reviews: