1
2
3
4
5
6
15
G
Cleaning the filter tank
Blocked feed impeller
.
Example:
Hose pipe connection with the GARDENA light jet base
We recommend the use of a 3 /4
”
(19 mm) GARDENA pond
hose pipe, Art. No. 7895, connected to with the GARDENA
“Profi” Maxi-Flow-System with Tap Connector (Art. No. 2801
and 2802) and the GARDENA “Profi” Maxi-Flow-System Hose
connectors (Art. No. 2817).
Care instructions
Filter tank and pump should be free from dirt particles!
How to clean :
.
Pull the plug connections out of the transformer and disconnect
its power plug!
.
Remove the pump from the water.
.
If necessary remove the gravel.
.
Clean the pump and the filter using a water jet.
.
If there are deposits of dirt inside the pump then dismantle the
casing (
➔
➔
see „Dismantling”) and carefully clean the interior
fittings with water.
Information: Do not use any hard objects or strong detergents!
If the feed impeller becomes blocked, the pump and the filter
should be cleaned (see above).
Dismantling
1. Pull the plug connections out of the transformer and disconnect
its power plug!
2. Remove the pump from the water.
3. If necessary remove the gravel.
4. Pull the pump pointing vertically upwards out of the filter tank.
5. Pull the suction filter casing
1
for-
wards and remove it.
6. Remove the foam filter
2
from the
suction piece of the pump.
7. Turn the pump casing
3
to the left
to the limit stop and then pull it straight
towards the front and remove it!
Do not tilt!
8. Pull the feed impeller
4
out of the
motor casing
6
.
.
Then assemble all the fittings reversing the order and direction
in which they were dismantled. Please take care that the seal
ring
5
is properly re-fitted.
➔
Make sure while assembling that you attach the pump casing
with the pressure joint being cated, press it firmly and then
turn it straight to the right.
➔
Observe the markings.
14
G
Operation
1. Remove the pump from the filter basket and screw the regulator
supplied onto the second opening of the pump up to the limit
stop (
➔
max. delivery capacity on the vertical outlet). Then
replace the pump in the filter basket.
2. Put the pump on a stable base to ensure that the upper edge of
the filter tank is completely immersed in water.
Please note the maximum submersion depth (see “Technical Data”).
GARDENA
lightline Transformers are licensed for outdoor use.
.
You may attach them to the ground or the wall.
.
When attaching to the wall, please take care that the connection
sockets are pointing towards the ground.
.
When attaching to the ground, please take care that the trans-
former is not exposed to direct rainfall or to a mechanical
hazard.
Put the plug connection into a free socket of the transformer
and connect the power cable of the transformer with a 230 V AC
socket.
A
Caution! Pump will start running immediately!
Avoid dry operation of the pump as dry running will produce
undesirable heat and destroy the pump.
.
Loosen the regulator by turning it anti-clockwise until you
achieve the desired water flow from the vertical pipe of the
fountain / water feature.
.
You may connect other terminals to the second outlet.
For example, a separately installed water jet may be operated
via the GARDENA light jet base, Art. No. 7886. If necessary
fix the light jet base with two screws.
Information:
This significantly reduces the volume of the vertical water jet.
.
If the max. delivery capacity of the second outlet is to be used
then the vertical outlet should be closed with the end cap sup-
plied.
Installing the pump
Pay attention to
minimum water depth
Finding a location
for the transformer
Starting the pump
Avoid dry operation
Horizontal or
second outlet
2 m
2 m