G

Cleaning the filter tank

Blocked feed impeller

.

Example:

Hose pipe connection with the GARDENA light jet base 

We recommend the use of a 3 /4

(19 mm) GARDENA pond

hose pipe, Art. No. 7895, connected to with the GARDENA
“Profi” Maxi-Flow-System with Tap Connector (Art. No. 2801 
and 2802) and the GARDENA “Profi” Maxi-Flow-System Hose
connectors (Art. No. 2817).

Care instructions 

Filter tank and pump should be free from dirt particles!

How to clean :

.

Pull the plug connections out of the transformer and disconnect

its power plug! 

.

Remove the pump from the water.

.

If necessary remove the gravel.

.

Clean the pump and the filter using a water jet.

.

If there are deposits of dirt inside the pump then dismantle the

casing (

see „Dismantling”) and carefully clean the interior 

fittings with water.

Information: Do not use any hard objects or strong detergents!

If the feed impeller becomes blocked, the pump and the filter
should be cleaned (see above).

Dismantling

1. Pull the plug connections out of the transformer and disconnect

its power plug! 

2. Remove the pump from the water.
3. If necessary remove the gravel.
4. Pull the pump pointing vertically upwards out of the filter tank.

5. Pull the suction filter casing 

1

for-

wards and remove it.

6. Remove the foam filter 

2

from the 

suction piece of the pump.

7. Turn the pump casing 

3

to the left 

to the limit stop and then pull it straight
towards the front and remove it! 
Do not tilt! 

8. Pull the feed impeller 

4

out of the

motor casing 

6

.

.

Then assemble all the fittings reversing the order and direction 

in which they were dismantled. Please take care that the seal
ring 

5

is properly re-fitted.

Make sure while assembling that you attach the pump casing 
with the pressure joint being cated, press it firmly and then 
turn it straight to the right.

Observe the markings.

14

G

Operation

1. Remove the pump from the filter basket and screw the regulator 

supplied onto the second opening of the pump up to the limit
stop (

max. delivery capacity on the vertical outlet). Then

replace the pump in the filter basket.

2. Put the pump on a stable base to ensure that the upper edge of

the filter tank is completely immersed in water.

Please note the maximum submersion depth (see “Technical Data”).

GARDENA 

lightline Transformers are licensed for outdoor use.

.

You may attach them to the ground or the wall.

.

When attaching to the wall, please take care that the connection

sockets are pointing towards the ground.

.

When attaching to the ground, please take care that the trans-

former is not exposed to direct rainfall or to a mechanical
hazard.

Put the plug connection into a free socket of the transformer 
and connect the power cable of the transformer with a 230 V AC
socket.

A

Caution! Pump will start running immediately!

Avoid dry operation of the pump as dry running will produce 
undesirable heat and destroy the pump.

.

Loosen the regulator by turning it anti-clockwise until you 

achieve the desired water flow from the vertical pipe of the 
fountain / water feature.

.

You may connect other terminals to the second outlet.

For example, a separately installed water jet may be operated
via the GARDENA light jet base, Art. No. 7886. If necessary 
fix the light jet base with two screws.

Information:
This significantly reduces the volume of the vertical water jet.

.

If the max. delivery capacity of the second outlet is to be used

then the vertical outlet should be closed with the end cap sup-
plied.

Installing the pump 

Pay attention to 
minimum water depth

Finding a location 
for the transformer 

Starting the pump

Avoid dry operation

Horizontal or 
second outlet 

2 m

2 m

Summary of Contents for WP 600

Page 1: ...emploi Pompe pour jets d eau 12 V NL Gebruiksaanwijzing Waterspelpomp 12 V S Bruksanvisning Font n Pump Set 12 V I Istruzioni per l uso Pompa per giochi d acqua 12 V E Manual de instrucciones Bomba pa...

Page 2: ...ingebruikname van het apparaat zorgvuldig door Pagina Gebruiksaanwijzing 25 31 S L s igenom bruksanvisnin gen noggrant innan Du tar Din GARDENA Pump i bruk Sida Bruksanvisning 32 37 I Prima di metter...

Page 3: ...inner as well as salt water or food drinking water must not be pumped A For Your Safety The transformer should be operated via a residual current device with a residual current rating of 30 mA DIN VDE...

Page 4: ...r application Water jets may be integrated into water features Model Cascade Water Foaming Water Water Cascade Bell Jet Spray Fleur de Lis fall Rotating Art 7814 7816 7818 7820 7822 7823 No WP 600 12...

Page 5: ...ith the pressure joint being cated press it firmly and then turn it straight to the right Observe the markings 14 G Operation 1 Remove the pump from the filter basket and screw the regulator supplied...

Page 6: ...any damage caused by our units if it is due to improper repair or if parts exchanged are not original GARDENA parts or parts approved by us and if the repairs were not carried out by a GARDENA Servic...

Page 7: ...gos de agua Garantibevis Springvandspumpe Wurde gekauft am H ndlerstempel Was purchased on Dealer s stamp Receipt Achet e le date et lieu d achat Cachet du revendeur Werd gekocht op Stempel van de han...

Page 8: ...apest Iceland Heimilistaeki hf Saetun 8 P O Box 5340 125 Reykjavik Republic of Ireland Michael McLoughlin Sons Hardware Limited Long Mile Road Dublin 12 Italy GARDENA Italia S r l Via Donizetti 22 200...

Reviews: