Cleaning the filter tank

Blocked feed impeller

Avoid dry operation of the pump as dry running will produce 
undesirable heat and destroy the pump.

.

Loosen the regulator by turning it anti-clockwise until you

achieve the desired water flow from the vertical pipe of the 
fountain / water feature.

.

You may connect other terminals to the second outlet.

For example, a separately installed water jet may be operated
via the GARDENA Fountain / Light Bracket, Art. No. 7886.
If necessary fix the bracket with two screws.

Information:
This significantly reduces the volume of the vertical water jet.

.

If the max. delivery capacity of the second outlet is to be used

then the vertical outlet should be closed with the end cap sup-
plied.

.

Example:

Hose pipe connection with the GARDENA 

Fountain / Light Bracket

We recommend the use of a 3 /4

(19 mm) GARDENA Pond

Hose Pipe, Art. No. 7895, connected to with the GARDENA
“Profi” Maxi-Flow-System with Tap Connector (Art. No. 2801 
and 2802) and the GARDENA “Profi” Maxi-Flow-System Hose
Connectors (Art. No. 2817).

Care Instructions

Filter tank and pump should be free from dirt particles!

How to clean :

.

Disconnect the plug from the solar panel !  

.

Remove the pump from the water.

.

If necessary remove the gravel.

.

Clean the pump and the filter using a water jet.

.

If there are deposits of dirt inside the pump then dismantle the

casing (

see “Dismantling ”) and carefully clean the interior 

fittings with water.

Information: Do not use any hard objects or strong detergents!

If the feed impeller becomes blocked, the pump and the filter
should be cleaned (see above).

Avoid dry operation

Horizontal or 
second outlet 

Complaints / Repairs

Product liability

Dismantling

1.

Disconnect the plug from the solar panel !

2. Remove the pump from the water.
3. If necessary remove the gravel.
4. Pull the pump pointing vertically upwards out of the filter tank.

5. Pull the suction filter casing 

1

for-

wards and remove it.

6. Remove the foam filter 

2

from the 

suction piece of the pump.

7. Turn the pump casing 

3

to the left 

to the limit stop and then 
pull it straight towards the front and
remove it! Do not tilt! 

8. Pull the feed impeller 

4

out of the

motor casing 

6

.

.

Then assemble all the fittings reversing the order and direction 

in which they were dismantled. Please take care that the seal
ring 

5

is properly re-fitted.

Make sure while assembling that you attach the pump casing 
with the pressure joint being cated, press it firmly and then 
turn it straight to the right.

Observe the markings.

Storage

A

The pump should be stored out of the reach of children.

1. Remove the pump from the pond and store away from frost

before the first frost sets in.

2. Clean and check the pump carefully.
3. Store the pump in a container filled with water.

The mains plug must not be submerged.

Information

If you have any problems with your Fountain Pump, please con-
tact our Service or return the defective unit together with a short
description of the problem – in case of guarantee, with the 
warranty card duly completed and signed – postage paid to one 
of the GARDENA Service Centres listed on the back of this leaflet.

We expressly point out that, in accordance with the product 
liability law, we are not liable for any damage caused by our
units if it is due to improper repair or if parts exchanged are not
original GARDENA parts or parts approved by us, and, if the
repairs were not carried out by a GARDENA Service Centre or
an authorised specialist. The same applies to spare parts and
accessories.

Where to store

Summary of Contents for WP 700 S 7851

Page 1: ...laire pour jets d eau NL Gebruiksaanwijzing Waterspelpompset Solar S Bruksanvisning Font n Pump Set med solcellsdrift I Istruzioni per l uso Pompa a energia solare per giochi d acqua E Manual de instr...

Page 2: ...voor ingebruikname van het apparaat zorgvuldig door Pagina Gebruiksaanwijzing 25 31 S L s igenom bruksanvisnin gen noggrant innan Du tar Din GARDENA Pump i bruk Sida Bruksanvisning 32 37 I Prima di m...

Page 3: ...ro thinner as well as salt water or food drinking water must not be pumped A For Your Safety Before operating the pump look to see if there is any damage of the pump A damaged pump must not be used In...

Page 4: ...ied onto the second opening of the pump up to the limit stop max delivery capacity on the vertical outlet Then replace the pump in the filter basket 2 Put the pump on a stable base to ensure that the...

Page 5: ...Product liability Dismantling 1 Disconnect the plug from the solar panel 2 Remove the pump from the water 3 If necessary remove the gravel 4 Pull the pump pointing vertically upwards out of the filter...

Page 6: ...89079 Ulm hereby certifies that when leaving our factory the units indicated below are in accordance with the harmonised EU guidelines EU standards of safety and product specific standards This certif...

Page 7: ...ta de garant a Set de bomba solar para juegos de agua Garantibevis Solcelledrevet Springvandspumpe S t Wurde gekauft am H ndlerstempel Was purchased on Dealer s stamp Receipt Achet e le date et lieu d...

Page 8: ...a 22 1158 Budapest Iceland Heimilistaeki hf Saetun 8 P O Box 5340 125 Reykjavik Republic of Ireland Michael McLoughlin Sons Hardware Limited Long Mile Road Dublin 12 Italy GARDENA Italia S r l Via Don...

Reviews: