background image

SYMBOLS

SPECIFICATIONS

Bulb Type:

 FLT-10 & FLT-20 includes bright Krypton Bulb KPR102

Batteries:

 FLT-10 & FLT-20 use two C-size batteries

    CAM-10 Use 2 LR44 button cell batteries
Operating Range:

 50-600 VAC, 50-60 Hz

Voltage Indicators:

 Audible & Visual Alert

Operating Temperature:

 32-122°F (0-50°C)

Storage Temperature:

 0°F (-18°C) to 156°F (70°C) 

Humidity:

 80% RH maximum below 86˚F(30˚C), 50% RH maximum above 86°F (30°C)

    

Altitude:

 Up to 6561 feet (2000 meters)

Safety:

 For indoor use and in accordance with over voltage category III, Pollution degree 2

Intended Use:

 Non-contact AC voltage detection

Serial No:

 See interior of battery cover

CLEANING

Use clean, dry cloth. Do not use any type of solvent. 

BEFORE USE

READ ALL OPERATING INSTRUCTIONS BEFORE USE.  FOR 
INTENDED USE ONLY. 

Protection provided by this product may be 

impaired if used with accessories not provided by the manufacture or if 

used as in a manner other than specified within.

!

WARNING:

 Do not dispose of batteries in fire. Batteries may explode or 

leak causing injury.

WARNING:

 

To be used by trained person only. 

High voltage AC and DC

circuits are dangerous.  Use extreme caution and use as intended when

testing potentially live circuits. Risk of Electrocution.

WARNING:

This product should be used to test or detect insulated 

wires and terminals but should not be used to contact Live Circuits.

This tester will not detect voltage in wires that are

electrically shielded by metal conduit or grounded enclosures.

Risk of Electrocution. 

OPERATION

Before use, test the batteries of the CAM-10 tester by pressing the button 

on the tester marked PRESS. A momentary audible tone and flash of the 

light are an indication that the unit is working.  

WARNING:

 Always test on known live circuit before use.

To test for voltage:

1. Hold the work light with your thumb on the CAM-10

tester button marked PRESS, keeping hands 

and fingers well away from the sensor (red end). 

2. Press down and hold the test button on

the tester. A momentary alert indicates

the unit is working.  

3. Place the sensor (red end) near the wire

or device to be tested. Maintain a minimum 

distance of 0.5mm from contacting the wire

or device to be tested. If voltage greater 

than 50 VAC is present, the tester light

and tone will activate rhythmically at 10 to 15

cycles second. 

To detach the tester

 from the work light, 

apply force to the tester near the 

Gardner Bender logo and slide the tester from 

the holding slot. The tester can be used to test for 

voltage after it is detached per instructions within. Hold the tester as 

shown, keeping hands and fingers well away from the sensor (red end).

CAM-10 BATTERY REPLACEMENT

Remove the Phillips

®

 head screw from the bottom of the CAM-10 tester. 

Lift off the battery cover from the top of the tester. Insert 2 LR44 batteries 

in the orientation indicated on the side of the battery cover. Replace 

cover and screw.

BULB REPLACEMENT:

 Use one (1) KPR102 or equivalent.

1. Remove the circuit alert module from the flashlight.

2. Turn the lens ring counterclockwise until it detaches 

from the housing.

3. Remove the old bulb and insert the new bulb.

4. Press reflector firmly into housing, reattach lens ring.

ESPECIFICACIONES

Tipo de bombilla: 

Los modelos FLT-10 y FLT-20 incluyen bombilla

    brillante Krypton KPR102

Baterías: 

Los modelos FLT-10 y FLT-20 usan dos baterías tamaño C

    El modelo CAM-10 usa 2 baterías de botón LR44
Rango operativo: 

50-600 VCA, 50-60 Hz

Indicadores de voltaje:

 Alerta sonora y visual

Temperatura operativa: 

0-50°C

Humedad: 

80% HR máxima, 50% HR máxima sobre 30°C

Altitud:

 Hasta 2000 metros.

Seguridad: 

Para uso en interiores y conforme a la categoría III 

    de sobrevoltaje

    Grado de contaminación 2. IEC 529, IEC 1010
Uso previsto: 

Detección de voltaje CA sin contacto

LIMPIEZA

Use un paño limpio y seco. No use ningún tipo de solvente. 

ANTES DEL USO

LEA TODAS LAS INSTRUCCIONES OPERATIVAS ANTES DEL USO.  
SÓLO PARA EL USO PREVISTO.

!

ADVERTENCIA: 

Son peligrosos los circuitos de CA y CC de alto voltaje.  

Tenga sumo cuidado y utilice de la manera prevista al probar circuitos 

potencialmente energizados. Riesgo de electrocución.

ADVERTENCIA: 

Son peligrosos los circuitos de CA y CC de alto voltaje.  

Tenga sumo cuidado y utilice de la manera prevista al probar circuitos 

potencialmente energizados. Riesgo de electrocución.

ADVERTENCIA: 

Este probador no detecta el voltaje en cables que 

tienen blindaje eléctrico mediante portacables de metal o cierres puestos 

a tierra. Riesgo de electrocución.

OPERACIÓN

Antes de usar, pruebe las baterías del probador CAM-10 oprimiendo 

el botón en el probador que está marcado PRESS. Un tono audible 

momentáneo y un destello de luz son indicaciones de que 

la unidad está funcionando.  

ADVERTENCIA: 

Siempre pruebe en un circuito 

energizado conocido antes de usar.

Para probar el voltaje:
1. Sostenga la luz de trabajo con el pulgar en 

el botón del probador CAM-10 marcado 

PRESS, manteniendo las manos y los 

dedos bien alejados del sensor 

(extremo rojo).

Limited Lifetime Warranty limited solely to repair or replacement; no warranty or 

merchantability or fitness for a particular purpose. Product is warrantied to be free 

of defects in materials and workmanship for the normal life of the product. In no 

event shall Gardner Bender be liable for incidental or consequential damage.

FLT-10, FLT-20

Work Light

CAM-10

Non-contact Voltage Tester

OPERATING 

INSTRUCTIONS

Patents Pending

FLT-10, FLT-20

Luz de trabajo 

CAM-10

Probador de voltaje sin contacto

INSTRUCCIONES

OPERATIVAS

Patentes pendientes

This equipment has double insulation with respect to live circuits
Attention, consult the accompanying documents

!

!