background image

1.0  Description  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2

2.0 Safety Symbol Definitions  . . . . . . . . . . . . . . . . . .2

3.0 Warnings  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2

4.0 Grounding Instructions . . . . . . . . . . . . . . . . . . . . .3

5.0 Technical Specifications  . . . . . . . . . . . . . . . . . . .3

6.0 Product Description  . . . . . . . . . . . . . . . . . . . . . . .3

7.0 Use and Operation . . . . . . . . . . . . . . . . . . . . . . . .4

7.1 Blowing Line in Conduit  . . . . . . . . . . . . . . . . .4

7.2 Preparation  . . . . . . . . . . . . . . . . . . . . . . . . . .4

7.3 Selecting the Pull Lines  . . . . . . . . . . . . . . . . .4

B3000 Blower for B60

B4500K Blower Kit

RPS-0106

01/02 

Instruction Sheet

B4500K, B60, BV208DA

IMPORTANT RECEIVING INSTRUCTIONS

Visually inspect all components for shipping damage. If shipping damage is found, notify carrier at once. Shipping damage is NOT
covered by warranty. The carrier is responsible for all repair and replacement costs resulting from damage in shipment.

SAFETY ISSUES

IMPORTANT – USER SAFETY AND PROTECTION: In setting up systems to fit your operations, care must be taken to select the
proper components and design to insure appropriate that all safety measures have been taken to avoid the risk of personal injury
and property damage from your application or system.

GARDNER BENDER IS NOT RESPONSIBLE FOR DAMAGE OR INJURY CAUSED BY UNSAFE USE, MAINTENANCE OR THE
APPLICATION OF ITS PRODUCTS. Please contact Gardner Bender for guidance when you are in doubt as to the proper safety
precautions to be taken in designing and setting up your particular application.

7.4 Power Saver™ Line Packages  . . . . . . . . . . .5

7.5 Tag-Along™ Line Packages  . . . . . . . . . . . . .5

7.6 PL Series Pull Line  . . . . . . . . . . . . . . . . . . . .5

7.7 Seal-Offs  . . . . . . . . . . . . . . . . . . . . . . . . . . . .6

7.8 Line Carriers  . . . . . . . . . . . . . . . . . . . . . . . . .7

7.9 Blowing or Vacuuming Thru Conduit  . . . . . . .8

8.0 Maintenance  . . . . . . . . . . . . . . . . . . . . . . . . . . .10

9.0 Jetline

®

Systems  . . . . . . . . . . . . . . . . . . . . . . . .10

9.1 B4500K Line Shooter™ Blowing System  . .11

9.2 B60 Super Blower™ System  . . . . . . . . . . . .12

BV208DA Blo-Vac™

Summary of Contents for JetLine B4500K

Page 1: ...ND PROTECTION In setting up systems to fit your operations care must be taken to select the proper components and design to insure appropriate that all safety measures have been taken to avoid the ris...

Page 2: ...vicing CAUTION To reduce the risk of electrical shock Do not expose to rain Store indoors CAUTION Use only as described in this manual Use only manufacturer s recommended attachments WARNING Do not us...

Page 3: ...ccurs making it difficult to maintain pressure or vacuum to place a line in the conduit Blower Systems GB JetLine supplies two blower systems the B4500K Line Shooter for fishing from 1 2 through 4 tra...

Page 4: ...There are some conduit runs that will be difficult or impossible to blow a line in such as Conduit containing hard packed sand silt debris or concrete Conduit containing water with a head greater than...

Page 5: ...ing These lines are made of strong polyolefin plastic that will not rust rot or mildew The coreless wound roll of knot free pull line makes center dispensing from the carton a convenient feature when...

Page 6: ...he feed port when Power Saver or Tag Along line packages are used or when vacuuming JV08 Short Seal Off The JV08 Seal Off is used in close quarters such as 2 x 4 electrical boxes etc It may be used on...

Page 7: ...local obstructions that would stop a foam line carrier In large conduit 4 5 and 6 the Inflatables may lie against the conduit wall It may be necessary to point the seal off nozzle toward the inflatabl...

Page 8: ...conduit Tag Along Line Package Tag Along line packages perform the same function as Power Saver line packages except they are used in 11 4 diameter and larger conduit Tag Along package must be used w...

Page 9: ...e line carrier to prevent loss of the line in the conduit 5 Insert the line carrier in the conduit and hold the seal off firmly in the conduit entrance and turn on the blower Vacuuming Pull Line in th...

Page 10: ...an the filter bag by shaking off the excess dirt and store the clean bag in the lower compartment 4 The Blo Vac is equipped with a ball float to prevent water from entering the motor If the ball float...

Page 11: ...ly 1 8 lbs 3 BR 1060 1 Heavy duty Hose 11 2 dia 9 lb 4 BR 1003 Long Seal off for 1 2 1 conduit 4 lb 5 BR 1004 Seal off for 11 4 11 2 conduit 1 3 lbs 6 BR 1005 Seal off for 2 4 conduit 1 2 lbs 7 BR 165...

Page 12: ...prepaid PARTS AND SERVICE For quality workmanship and genuine Gardner Bender parts select an Authorized GB Service Center for your repair needs Only repairs performed by an Authorized Service Center...