13-18-607 Page 77
SYMPTOM
POSSIBLE CAUSE
REMEDY
5.
Compressor lock-up
5.
Confirm compressor shaft is not free to
turn. Contact GD for further
instructions.
Compressor
does not
unload (or
load)
1.
Improperly adjusted controller
1.
Refer to Manual 13-17-600 and adjust
control.
2.
Feed pressure regulator not
adjusted
2.
Inspect, adjust and replace pressure
regulator.
3.
Feed 3-way solenoid valve
malfunction
3.
Repair, clean or replace valve.
4.
Inlet valve stuck
4.
Inspect and replace valve.
5.
Blow down valve malfunction
5.
Repair, clean or replace valve.
Compressor
cycles from
load to unload
excessively
1.
Insufficient receiver capacity
1.
Increase receiver size
2.
Restriction in service piping
2.
Inspect and clean service piping.
3.
Restriction in control tubing
3.
Inspect and clean control tubing.
Compressor
starts too
slowly
1.
Acceleration time in VFD set too
long
1.
Contact your Gardner Denver
distributor.
2.
Minimum Pressure/Check Valve
is leaking
2.
Repair or replace.
Compressor is
low on delivery
and pressure
1,
Improperly adjusted control
1.
Refer to Manual 13-17-600 and adjust
control.
2.
Restricted air filter
2.
Clean or replace filter element.
3.
Inlet valve not fully open
3.
Inspect, adjust or replace feed solenoid
valve and/or pressure regulator.
4.
Minimum pressure valve stuck
closed
4.
Inspect service or replace valve.
5.
Blowdown valve leaking
5.
Inspect or replace solenoid valve.
Ensure local ambient temperature has
not exceeded 113
°
F. limit.
6.
Air demand exceeds supply
6.
Make sure air demand matches
compressor specifications for flow and
pressure.
Summary of Contents for AirSmart VS135A
Page 29: ...13 18 607 Page 28 Figure 4 2 PIPING AND INSTRUMENTATION ILLUSTRATION 305CGF797 A Ref Drawing...
Page 31: ...13 18 607 Page 30 300CGF546 D Ref Drawing Page 2 of 4...
Page 32: ...13 18 607 Page 31 300CGF546 D Ref Drawing Page 3 of 4...
Page 33: ...13 18 607 Page 32 300CGF546 D Ref Drawing Page 4 of 4...
Page 35: ...13 18 607 Page 34 302CGF546 E Ref Drawing Page 2 of 4...
Page 36: ...13 18 607 Page 35 302CGF546 E Ref Drawing Page 3 of 4...
Page 37: ...13 18 607 Page 36 302CGF546 E Ref Drawing Page 4 of 4...
Page 39: ...13 18 607 Page 38 303CGF546 C Ref Drawing Page 2 of 4...
Page 40: ...13 18 607 Page 39 303CGF546 C Ref Drawing Page 3 of 4...
Page 41: ...13 18 607 Page 40 303CGF546 C Ref Drawing Page 4 of 4...
Page 43: ...13 18 607 Page 42 305CGF546 C Ref Drawing Page 2 of 4...
Page 44: ...13 18 607 Page 43 305CGF546 C Ref Drawing Page 3 of 4...
Page 45: ...13 18 607 Page 44 305CGF546 C Ref Drawing Page 4 of 4...
Page 81: ......