13-18-612 Page 16
2-4
Refer to Engineering Data Sheet 13-9-411, available from an authorized Gardner Denver distributor, for
the advantages of using the heat recovered from rotary compressors. This heat recovery could easily
pay for an adequate shelter for the unit.
AUXILIARY AIR RECEIVER
- An auxiliary air receiver is not required if the piping system is large and
provides sufficient storage capacity to prevent rapid cycling. An adequate receiver capacity for the VS
units is ½ gallon for each cfm delivered by the compressor package.
OPTIONAL MOISTURE SEPARATOR/TRAP
– The unit can be provided with an optional stand-alone
combination moisture separator and trap that is field-installed downstream of the aftercooler.
CONTROL PIPING
- Control piping is not necessary since the Gardner Denver compressor package is
factory wired and piped for the control system specified.
INLET LINE
– The air filter assembly used in the VS compressor package is not suitable for relocation, as
its housing assembly is an integral part of the enclosure sheet metal components. See page 13 for
LOCATION comments on this section of the manual for duct work recommendations to bring in ventilation
air.
DISCHARGE SERVICE LINE
- The discharge service line connection on both water cooled and air
cooled units is located at the upper right hand area of the intake grill side of the enclosure. Gardner
Denver compressor packages are inherently isolated from the service line by their own minimum
pressure/check valves. The installer or end user must ensure that other compressors that are piped into
a common pipe manifold with the Gardner Denver compressor package are each provided with an
isolation check valve. It is recommended that an additional receiver be installed between the rotary screw
and reciprocating compressors sharing a common pipeline. Do not install another check valve in the
unit’s discharge line as operational upsets will occur.
Discharge air used for breathing will cause severe injury or death.
Consult filtration specialists for additional filtration and treatment equipment to meet
health and safety standards.
BLOW DOWN VALVE PIPING
– The blow down valve is vented between the air filter and inlet valve,
thus avoiding the need of any external pipe work.
WATER PIPING (Water Cooled Heat Exchanger Models Only)
- On machines equipped with water
cooled heat exchangers, the water inlet and outlet connections are located on the lower, right-hand area
below the intake grill.
It is mandatory that any water cooled unit be installed in a shelter heated to
temperatures above freezing (40
F., 5
C).
Summary of Contents for AirSmart VS80-110B
Page 33: ...13 18 612 Page 32 4 7 300CGE546 04 Ref Drawing Page 2 of 4...
Page 34: ...13 18 612 Page 33 4 8 300CGE546 04 Ref Drawing Page 3 of 4...
Page 35: ...13 18 612 Page 34 4 9 300CGE546 04 Ref Drawing Page 4 of 4...
Page 37: ...13 18 612 Page 36 4 11 301CGE546 B Ref Drawing Page 2 of 4...
Page 38: ...13 18 612 Page 37 4 12 301CGE546 B Ref Drawing Page 3 of 4...
Page 39: ...13 18 612 Page 38 4 13 301CGE546 B Ref Drawing Page 4 of 4...
Page 41: ...13 18 612 Page 40 4 15 302CGE546 05 Ref Drawing Page 2 of 4...
Page 42: ...13 18 612 Page 41 4 16 302CGE546 05 Ref Drawing Page 3 of 4...
Page 43: ...13 18 612 Page 42 4 17 302CGE546 05 Ref Drawing Page 4 of 4...
Page 45: ...13 18 612 Page 44 4 19 303CGE546 B Ref Drawing Page 2 of 4...
Page 46: ...13 18 612 Page 45 4 20 303CGE546 B Ref Drawing Page 3 of 4...
Page 47: ...13 18 612 Page 46 4 21 303CGE546 B Ref Drawing Page 4 of 4...
Page 70: ...13 18 612 Page 69 9 2 Figure 9 1 MINIMUM DISCHARGE PRESSURE CHECK VALVE...
Page 86: ...NOTES...
Page 87: ...NOTES...