13-18-612 Page 47
5-1
SECTION 5
COMPRESSOR LUBRICATION
– SEPARATION, FILTRATION AND CONTROLS
Air/oil under pressure will cause severe personal injury or death. Shut down
compressor, relieve system of all pressure, disconnect, lockout and tagout power
supply to the compressor package before removing valves, caps, plugs, fittings, bolts
and filters.
High temperature operation can cause damage to equipment or personal injury. Do not
restart the unit repeatedly after high temperature shutdown. Find and correct the
malfunction before resuming operation.
COMPRESSOR OIL SYSTEM
– Lubricating oil is employed to absorb the heat of compression, lubricate
moving parts and seal internal clearances between the rotor and air cylinder. Pressure differential
between the air/oil reservoir and various injection points is used to flow oil through the package.
Oil exits the air/oil sump and is then routed to the heat exchanger and the thermal mixing valve, where
cold (oil cooler branch) and hot (bypass branch) are mixed to a temperature that will avoid water vapor
condensation within the oil system. Tempered oil is sent to the oil filter for cleaning, then onto injection.
The injected oil absorbs heat from compression while progressing through the compression chamber and
is then discharged back into the oil separation chamber as a mixture of liquids and aerosols (oil) and gas
(air).
Centrifugal action within the air/oil reservoir separates the bulk of the oil from the air, where it is collected
and readied for the next cooling cycle. The compressed air and aerosols continue through a coalescing
filter, where all but 2 ppm of oil concentration is removed from the compressed air and discharged to the
aftercooler.
RECOMMENDED LUBRICANT
– The Gardner Denver compressor is factory-filled with AEON 9000SP
lubricant. This lubricant is formulated to the highest quality standards and is factory-authorized, tested
and approved for use in our rotary screw compressors. AEON 9000SP lubricant is available through your
authorized Gardner Denver compressor distributor.
OIL SPECIFICATIONS
- The factory fill compressor lubricant is Gardner Denver AEON 9000SP
lubricating coolant for all-year-round operation. This is a polyalphaolefin (PAO) synthetic lubricant
specially formulated for rotary screw compressor service.
It is highly recommended that the lubricating oil be analyzed frequently in order to identify its quality and
remaining operational life. A sampling valve, located on the heat exchanger manifold is provided for this
purpose.
Summary of Contents for AirSmart VS80-110B
Page 33: ...13 18 612 Page 32 4 7 300CGE546 04 Ref Drawing Page 2 of 4...
Page 34: ...13 18 612 Page 33 4 8 300CGE546 04 Ref Drawing Page 3 of 4...
Page 35: ...13 18 612 Page 34 4 9 300CGE546 04 Ref Drawing Page 4 of 4...
Page 37: ...13 18 612 Page 36 4 11 301CGE546 B Ref Drawing Page 2 of 4...
Page 38: ...13 18 612 Page 37 4 12 301CGE546 B Ref Drawing Page 3 of 4...
Page 39: ...13 18 612 Page 38 4 13 301CGE546 B Ref Drawing Page 4 of 4...
Page 41: ...13 18 612 Page 40 4 15 302CGE546 05 Ref Drawing Page 2 of 4...
Page 42: ...13 18 612 Page 41 4 16 302CGE546 05 Ref Drawing Page 3 of 4...
Page 43: ...13 18 612 Page 42 4 17 302CGE546 05 Ref Drawing Page 4 of 4...
Page 45: ...13 18 612 Page 44 4 19 303CGE546 B Ref Drawing Page 2 of 4...
Page 46: ...13 18 612 Page 45 4 20 303CGE546 B Ref Drawing Page 3 of 4...
Page 47: ...13 18 612 Page 46 4 21 303CGE546 B Ref Drawing Page 4 of 4...
Page 70: ...13 18 612 Page 69 9 2 Figure 9 1 MINIMUM DISCHARGE PRESSURE CHECK VALVE...
Page 86: ...NOTES...
Page 87: ...NOTES...